This laboratory study was approved by the institutional ethics committee of Kocaeli Health and Technology University (approval number 31/22) and was conducted in accordance with the ethical principles outlined in the Declaration of Helsinki and the PRILE 2021 guidelines28 (Supplementary File 1 and Supplementary File 2). Informed consent for the use of extracted teeth was obtained from the donors. The specimen model, groove preparation, and scoring followed a described protocol8. All materials, instruments, and software used in this protocol are listed in the Table of Materials.
Sample size calculation
The sample size was based on a previous investigation that used the same artificial groove model and scoring system26. In that study, an a priori power analysis (effect size = 0.6, α = 0.05, power = 0.95) indicated n = 12/each group, which the authors increased to 15 to compensate for possible losses. To increase precision, the present study used n = 20/each group, giving 400 grooves in total. This calculation addressed the main effect of the removal technique; no separate a priori calculation was made for the technique × sealer interaction. A post hoc sensitivity analysis based on the chi-square distribution of the Scheirer-Ray-Hare statistic (statsmodels 0.14.6) showed that the 200 grooves analyzed in each region gave 80% power (α = 0.05) to detect an interaction of effect size w = 0.24 (4 degrees of freedom) and a sealer main effect of w = 0.20 (1 degree of freedom), so that effects smaller than these, below Cohen's medium effect size of w = 0.3, may have escaped detection.
Sample selection criteria
Two hundred extracted human maxillary central incisors were used. After extraction, the teeth were disinfected in 2% NaOCl, rinsed with distilled water, and stored in thymol solution until use. Teeth with a straight single root canal and an intact apex were included, and a single canal was confirmed radiographically. Teeth with curvature, calcification, previous treatment, resorption, or an initial apical size of #30 or larger were excluded. The crowns were sectioned to a standard length, with a working length of 18 mm. Randomization was performed in two stages with a web-based random sequence generator (random.org): the 200 teeth were first allocated to the two sealers (n = 100 each), and the teeth of each sealer were then allocated to the five removal techniques (n = 20/each group), so that allocation was stratified by sealer. The random sequences were generated and applied by an investigator who did not perform scoring, and the specimens were labeled with coded identifiers to keep observers blinded to both the sealer and the removal technique.
CAUTION: Extracted human teeth represent a potential biohazard. Handle all specimens with appropriate personal protective equipment, including gloves, a mask, and protective eyewear.
Sample preparation
After patency was confirmed with an ISO size 10 K-file, the canals were enlarged to size 40/0.04 at the working length using a rotary endodontic instrumentation system under irrigation with 3% sodium hypochlorite (NaOCl), followed by a rinse of 5 mL of 3% NaOCl and 5 mL of 17% ethylenediaminetetraacetic acid (EDTA). All NaOCl solutions were prepared from a 5.25% stock solution by dilution with distilled water: 3% NaOCl by mixing 5.25% NaOCl and distilled water at a volume ratio of 4:3 (for example, 100 mL of 5.25% NaOCl and 75 mL of distilled water), and 5% NaOCl at a volume ratio of 20:1 (for example, 100 mL of 5.25% NaOCl and 5 mL of distilled water).
CAUTION: Sodium hypochlorite is caustic to the skin, eyes, and mucous membranes. Prepare and handle all solutions with gloves and protective eyewear, and avoid extrusion beyond the apical foramen.
The roots were embedded in impression material within centrifuge tubes and split longitudinally with a diamond disc, without penetrating the canal space. Any root in which the canal space was penetrated during splitting was to be excluded and replaced by a tooth prepared in the same way; no root met this criterion in the present series. Two artificial grooves, 4 mm long, 0.2 mm wide, and 0.5 mm deep, were cut into the canal wall with a prophylaxis scaling tip mounted on a piezoelectric ultrasonic endodontic unit at 40% power, under a dental operating microscope at ×20 magnification. The grooves were prepared on the opposite canal walls, at 2 to 6 mm and 10 to 14 mm from the apex (Figure 1). After groove preparation, the smear layer was removed using 2 mL of 17% EDTA.
The grooves of 100 teeth were filled with CeraSeal, and those of the remaining 100 teeth with BioRoot Flow using gutta-percha points. Complete filling of the grooves was confirmed under the dental operating microscope at ×20 magnification. The root halves were reassembled within the Eppendorf tubes, the access cavity was sealed with a temporary filling material, the apical foramen and the root surfaces were covered with wax, and the specimens were kept at 37 °C and 100% humidity for 30 days. Setting of the sealer was then verified under the dental operating microscope at ×20 magnification.
Removal procedures
Specimens for each sealer were assigned to five removal techniques (n = 20 per group), with SNI serving as the non-activated control. The SNI, PUI, R-SWEEPS, and Er,Cr:YSGG groups shared one irrigation regimen of six delivery-activation cycles, three with 5% NaOCl followed by three with 17% EDTA. In each cycle, 5 mL of irrigant was delivered over 150 s at 2 mL/min with an irrigation pump, and the irrigant filling the canal was then activated for 20 s with the technique under test. The three NaOCl cycles were completed before the three EDTA cycles, so that each specimen received 15 mL of 5% NaOCl and 15 mL of 17% EDTA (30 mL in total) and six 20 s activations (three per irrigant, 120 s in total). The treatment time in the three activated groups was therefore approximately 17 min (6 × 150 s of delivery plus 6 × 20 s of activation).
In the SNI group, the irrigants were delivered through a 30-G needle placed 2 mm short of the working length without activation; this group received the same volumes, flow rate, and irrigant sequence as the activated groups, but no waiting interval was interposed between deliveries in place of the activation periods, so that its total exposure time was approximately 15 min (6 × 150 s).
In the PUI group, the irrigant was activated using an IrriSafe size 20 tip mounted on the piezoelectric ultrasonic endodontic unit at 40% power, with the tip positioned 2 mm short of the working length, for three 20 s cycles per irrigant.
In the R-SWEEPS group, the irrigant was activated with a 2940 nm Er:YAG laser in R-SWEEPS mode using a radial tip (400 µm diameter, 14 mm length) held at the canal orifice without entering the canal, for three 20 s cycles per irrigant with the air and water spray switched off. In this mode, each 15 mJ pulse is delivered as one of a synchronized pair at a pulse-pair repetition rate of 15 Hz (30 mJ per pair), giving an average power of 0.45 W, 9 J per 20 s activation, and 54 J per specimen; the pulse energy corresponds to an energy density of 11.9 J/cm2 at the 400 µm tip end face.
In the Er,Cr:YSGG group, the irrigant was activated with a 2780 nm Er,Cr:YSGG laser in H mode (25 mJ per pulse, 50 Hz, 1.25 W; 25 J per 20 s activation and 150 J per specimen) using an RFT2 radial firing tip held 2 mm short of the working length, for three 20 s cycles per irrigant with the air and water spray switched off. In both laser groups, the canal was filled with the irrigant delivered by the pump before the laser was activated, and the parameters were the manufacturers' preset settings for endodontic irrigant activation, applied without modification. Table 1 gives the complete irradiation parameters, including the energy per pulse, the energy density, and the total energy delivered.
In the GentleWave G4 group, the reassembled specimen was kept in the centrifuge tube, a platform was built over the coronal end of the root with the manufacturer's SoundSeal resin to create an airtight seal between the endodontic irrigation instrument and the canal opening, and the automated procedure cycle of the GentleWave G4 system with ProControl software was run with the manufacturer's procedure fluids in the following sequence: 3% NaOCl for 5 min, distilled water for 30 s, 8% EDTA for 2 min, and a final distilled water rinse for 30 s (approximately 8 min in total). The procedure instrument was held in place by the platform for the entire cycle. The irrigant concentrations, flow rates, degassing, and cycle times are preset by the manufacturer and cannot be modified by the operator, so this group differed from the other four groups in irrigant concentration, volume, and treatment time (see Discussion section).
Assessment of residual sealer
The root halves were separated and examined under the dental operating microscope at ×20 magnification. Residual sealer in each groove was scored on a four-point scale29: 0, no sealer in the groove; 1, sealer in less than half; 2, sealer in more than half; and 3, the groove entirely filled. Two calibrated observers, blinded to the sealer and the removal technique, independently scored the grooves; interobserver agreement was κ = 0.92 (Cohen's kappa). Disagreements were resolved by consensus.
Statistical analysis
Data were analyzed using Python 3.9.6 with the SciPy 1.13.1, statsmodels 0.14.6, and scikit-posthocs 0.14.0 libraries. Apical and coronal grooves were analyzed separately. Residual sealer scores across the 10 groups were compared using the Kruskal-Wallis test, followed by the Dunn test with Bonferroni correction. Epsilon-squared was calculated as the effect size. The effects of sealer and removal technique, together with their interaction, were examined using the Scheirer-Ray-Hare test. Within each removal technique, the two sealers were compared using the Mann-Whitney U test with Bonferroni correction, and Cliff's delta with bootstrapped 95% confidence intervals was reported as the effect size. The significance level was set at 5%.