Gliotransmitter Release Measurement

Gliotransmitter release measurement is a set of methods used to detect and quantify signaling molecules released by glial cells, particularly astrocytes, helping clarify how glia communicate with neurons. These approaches monitor extracellular glutamate, ATP, D-serine, and related compounds after defined stimulation, using tools such as fluorescent or enzyme-based biosensors, microdialysis, and mass spectrometry. Measurements may be paired with calcium imaging or electrophysiology to link intracellular glial activity with chemical release and neuronal responses. In neuroscience, these data help evaluate glia-neuron communication, synaptic regulation, circuit function, and the contribution of glial signaling to neurological disease.

Gliotransmitter Release Measurement - Related Videos

Research

JoVE Journal - Neuroscience

Single Cell Measurement of Dopamine Release with Simultaneous Voltage-clamp and Amperometry

0 Views •

Cited by 1 •

2012

The amperometric technique measures dopamine release from a single cell by detecting the oxidative current produced by spontaneous dopamine oxidization. Simultaneous voltage clamp and amperometry methodology reveal the mechanistic relationship between the overall "activity" of dopamine transporter and the regulatory role of this activity on the reverse transport of dopamine.

Detection of Exosomal Biomarker by Electric Field-induced Release and Measurement (EFIRM)

0 Views •

Cited by 43 •

2015

Exosomes are microvesicular structures found within biofluids that potentially carry important disease discriminatory biomarkers. Here, a novel method is used to specifically extract exosomes and rapidly test the exosomal cargo for both RNA/protein targets following the disruption of exosomes using non-uniform electric cyclic square waves.

Measuring Mast Cell Exocytosis via Neuropeptide Y Monomeric Red Fluorescent Protein Release

0 Views •

2025

This video demonstrates mast cell exocytosis induced by an activating reagent that includes a calcium ionophore, initiating the release of secretory granules containing the fluorescent reporter protein NPY-mRFP. Subsequently, we quantitatively assess the exocytosis by measuring the released NPY-mRFP using a fluorescence plate reader.

High Throughput Measurement of Extracellular DNA Release and Quantitative NET Formation in Human Neutrophils In Vitro

0 Views •

Cited by 46 •

2016

High throughput assays are presented that in combination provide excellent tools to quantitate NET release from human neutrophils.

A Plate-Based Assay to Measure Monoamine Release from Brain Slices on Test Drug Exposure

0 Views •

2025

In this video, we demonstrate an assay that investigates monoamine release mechanisms from the neurons of metabolically active ex vivo rat brain slices, when treated with test drugs. The assay demonstrates that neurostimulant drugs induce monoamine release via the cellular monoamine transporters, whereas high KCl concentration induces synaptic vesicle exocytosis-mediated vesicular monoamine release.

View All Results