Erratum: Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere

281 görüntülenme

6 Aralık 2018

Bu makalede

Özet

An erratum was issued for: Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere. The Protocol section was updated.

Özet

An erratum was issued for: Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere. The Protocol section was updated.

In 2.2.7, the temperature coefficient of water, αf, for λ = 1150 nm has been corrected from:

4.0 x 10-3 K-1 mm-1

to:

2.8 x 10-4 K-1 mm-1

Protokol

An erratum was issued for: Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere. The Protocol section was updated.

In 2.2.7, the temperature coefficient of water, αf, for λ = 1150 nm has been corrected from:

4.0 x 10-3 K-1 mm-1

to:

2.8 x 10-4 K-1 mm-1

Açıklamalar

No conflicts of interest declared.

Yeniden basım ve izinler

Etiketler

İndüksiyonla Isıtılan Manyetik KüreSu Sıcaklık KatsayısıSıcaklık Düzeltme ProtokolüYakın Kızılötesi SpektroskopiManyetik İndüksiyon IsıtmaKüreyi Çevreleyen SuErratum DüzeltmesiProtokol Güncellemesi