Posterior Stabilized Prosthesis

A posterior stabilized prosthesis is a total knee arthroplasty implant designed to replace the stabilizing function of the posterior cruciate ligament (PCL) when that ligament is absent or intentionally removed. Its femoral component contains a cam that engages a post on the tibial insert during knee flexion, helping guide femoral rollback and limit excessive posterior translation of the tibia. This design can provide stability and predictable motion in patients undergoing knee replacement, particularly when the PCL cannot be preserved or is insufficient. Understanding its biomechanics supports implant selection, surgical planning, postoperative assessment, and evaluation of complications such as instability or wear.

Posterior Stabilized Prosthesis - Related Videos

Research

JoVE Journal - Bioengineering
Free Sample

Oscillation and Reaction Board Techniques for Estimating Inertial Properties of a Below-knee Prosthesis

0 Views •

Cited by 35 •

2014

Body segmental inertial properties are required for inverse dynamics modeling. Using an oscillation and reaction board technique, inertial properties of below-knee prostheses were measured. Using direct measures of prosthesis inertia in the inverse dynamics model of the prosthetic leg resulted in lower magnitudes of resultant joint forces and moments.

Research

JoVE Journal - Bioengineering

Engineering Platform and Experimental Protocol for Design and Evaluation of a Neurally-controlled Powered Transfemoral Prosthesis

0 Views •

Cited by 15 •

2014

Neural-machine interfaces (NMI) have been developed to identify the user's locomotion mode. These NMIs are potentially useful for neural control of powered artificial legs, but have not been fully demonstrated. This paper presented (1) our designed engineering platform for easy implementation and development of neural control for powered lower limb prostheses and (2) an experimental setup and protocol in a laboratory environment to evaluate neurally-controlled artificial legs on patients with...

A Standardized Method for Measuring Internal Lung Surface Area via Mouse Pneumonectomy and Prosthesis Implantation

0 Views •

Cited by 22 •

2017

Internal lung surface area (ISA) is a critical criterion for assessing lung morphology and physiology in lung diseases and injury-induced alveolar regeneration. We describe here a standardized method that can minimize the measurement bias for ISA in both lung pneumonectomy and prosthesis implantation mouse models.

Research

JoVE Journal - Medicine
Free Sample

Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks

0 Views •

Cited by 23 •

2015

Here we describe histological techniques for visualising ocular tissue directly adjacent to a metal epiretinal tack and retinal prosthesis.

Education

JoVE Core - Chemistry

Nuclear Stability

0 Views •

2020

Protons and neutrons, collectively called nucleons, are packed together tightly in a nucleus. With a radius of about 10−15 meters, a nucleus is quite small compared to the radius of the entire atom, which is about 10−10 meters. Nuclei are extremely dense compared to bulk matter, averaging 1.8 × 1014 grams per cubic centimeter. If the earth’s density were equal to the average nuclear density, the earth’s radius would be only about 200 meters. To hold positively charged protons together in the...

View All Results

FAQs

Related Topics