Take a mouse brainstem slice containing the medial vestibular nucleus, or MVN.

Secure the slice in a recording chamber filled with artificial cerebrospinal fluid to maintain neuronal viability.

Visualize the slice under a microscope to locate MVN neurons.

Apply positive pressure to advance a micropipette filled with an intracellular environment-mimicking solution through the tissue.

As the pipette contacts a neuron, the neuronal membrane will dimple.

Apply negative pressure to aspirate a small membrane portion, creating a tight seal.

Next, apply negative pressure pulses to rupture the membrane, creating a continuous connection between the neuron and the pipette.

Apply random noise amplitudes to the neuron and identify a subthreshold amplitude beyond which the noise induces neuronal firing.

Finally, apply a range of electrical stimuli to the neuron combined with the subthreshold random noise amplitude.

Measure neuronal gain — the neuron's ability to modulate its firing response to the stimuli in the presence of noise.

For whole-cell patch clamp electrophysiology, first, pull micropipettes with a final resistance that will range from 3 to 5 megaohms when filled with a potassium-based internal solution, and place in the bath. To obtain whole-cell patch clamp recordings from individual neurons in the MVN, transfer a single tissue slice from the incubation chamber to the recording chamber of a standard electrophysiological setup, and use a nylon thread on a U-shaped weight to secure the slice.

Continuously perfuse the recording chamber with carbogenated aCSF at 25 degrees Celsius at a flow rate of three milliliters per minute, and fill a micropipette with internal solution. Apply a small amount of positive pressure using a pipette to push debris away from the pipette tip. Using a lower power objective, locate the MVN before switching to a high power to locate individual neurons within the MVN.

Before breaching the tissue with the pipette, apply a small amount of positive pressure to push debris away from the pipette tip, and use the micromanipulator to move the pipette toward the selected neuron. A small dimple should form on the neuronal membrane. Release the positive pressure and apply a small amount of negative pressure.

Once a one gigaohm seal has been achieved, apply gentle, short, and sharp negative pressure to the pipette holder through the suction port to rupture the membrane and to create a whole-cell configuration. Then, obtain whole-cell current clamp recordings according to standard protocols.

To apply stochastic and sinusoidal noise to individual medial vestibular nucleus neurons, set the range of amplitudes from 3 to 24 picoamps to determine the neuronal threshold and firing rate, and group the lower and higher stimulus intensities to determine the sensory threshold.

Next, calculate the average firing rate over the 10-second period during which the depolarizing current step will be injected for each individual current level. Use the average firing rate values to generate a firing rate versus current plot. Then, perform a linear regression analysis to determine the gradient of the line of best fit to determine the neuronal gain.

09:54

Multifunctional, Micropipette-based Method for Incorporation And Stimulation of Bacterial Mechanosensitive Ion Channels in Droplet Interface Bilayers

Related Videos

0 Views

07:23

Whole-cell Patch-clamp Recordings in Brain Slices

Related Videos

0 Views

05:02

Using Unidirectional Rotations to Improve Vestibular System Asymmetry in Patients with Vestibular Dysfunction

Related Videos

0 Views

06:42

Application of a NMDA Receptor Conductance in Rat Midbrain Dopaminergic Neurons Using the Dynamic Clamp Technique

Related Videos

0 Views

03:45

Whole-Cell Patch Clamp Recording in a Substantia Gelatinosa Neuron of a Spinal Cord Slice

Related Videos

0 Views

03:34

Establishing a Whole-Cell Patch Clamp for Electrophysiological Recording from Vomeronasal Sensory Neurons

Related Videos

0 Views

02:59

Auditory Nerve Root Stimulation and Postsynaptic Current Recordings in a Mouse Brain Wedge Slice

Related Videos

0 Views

02:50

Perforated Patch-Clamp Recordings of Inner Ear Sensory Neuron Cell Bodies

Related Videos

0 Views

04:11

Whole-Cell Patch Clamp Recordings on Intact Rat Dorsal Root Ganglia

Related Videos

0 Views

08:58

Whole Cell Patch Clamp for Investigating the Mechanisms of Infrared Neural Stimulation

Related Videos

0 Views

Last updated: 18 July 2026