-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Encyclopedia of Experiments
Neuroscience
Implantation of an Electrode Assembly in a Mouse Brain for Electrophysiological Recording
Implantation of an Electrode Assembly in a Mouse Brain for Electrophysiological Recording
Encyclopedia of Experiments
Neuroscience
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
Encyclopedia of Experiments Neuroscience
Implantation of an Electrode Assembly in a Mouse Brain for Electrophysiological Recording

Implantation of an Electrode Assembly in a Mouse Brain for Electrophysiological Recording

Protocol
1,652 Views
05:36 min
July 8, 2025

Transcript

Secure an anesthetized mouse on a stereotaxic frame containing a heating pad to maintain body temperature.

Apply lubricant to prevent the eyes from drying and inject an electrolyte solution subcutaneously to maintain hydration.

Remove the fur from the scalp, disinfect the area, and inject an analgesic subcutaneously to reduce pain.

Make an incision to expose the skull, then clean it to make anatomical landmarks visible for identifying brain regions.

Apply dental adhesive and harden it using a curing light to aid in electrode implantation.

Drill holes above the hippocampus and cerebellum, and mount an electrode assembly using a holder on the stereotaxic frame.

The bipolar electrodes record hippocampal activity, while a reference electrode obtains baseline activity from the cerebellum.

Insert the electrodes, secure the assembly with dental cement, and detach from the holder.

Administer the electrolyte solution and an analgesic again.

Allow the mouse to completely recover before performing electrophysiological recording.

Before proceeding with the surgery, record the weight of the 8-week-old VGAT-Cre mice. Then, place the animal in an induction chamber to induce anesthesia. Place the anesthetized mouse on a heating pad at 37 degrees Celsius. If using a feedback-controlled temperature system, insert the temperature probe into the rectum of the animal for temperature monitoring during the surgery. To start the surgery, redirect the inhalant anesthesia flow to the nose cone and mount the animal in the stereotaxic frame by gently placing the front upper teeth into the incisor bar and move the cone onto its nose, then place the ear bars into the ears and affix to the stereotaxic frame.

Ensure that the animal's head is leveled and centered and cannot be moved when slightly probed. Once the animal is mounted, inject 0.5 milliliters of normosol onto the mice for hydration and apply ocular lubricant to prevent corneal drying. Monitor the depth of anesthesia by pinching a hind-limb toe. If the withdrawal reflex is absent in the animal, proceed to remove the scalp hair of the mouse around the surgical area. When done, disinfect the clean skin area thrice with an alternating application of ethanol and iodine finishing with iodine, and inject 0.05 milliliters of 0.25% bupivacaine subcutaneously.

Make an incision on the skull using a scalpel, and then, cut out a part of the skin with surgical scissors exposing the skull. Push the skin aside before cleaning the skull from all underlying tissues with a cotton swab. Clean the skull with hydrogen peroxide using sterile cotton swabs, and make the skull sutures, bregma, and lambda visible. With the stereotaxically mounted drill, Move the drill tip onto bregma and zero x, y, and z coordinates, then, raise and move the drill to lambda to determine its coordinates to determine if the head is level.

After drying the skull thoroughly, apply one drop of self-etching dental adhesive with the applicator. Wait 60 seconds before curing the dental adhesive with a dental UV light for 40 seconds. A glossy surface indicates that the adhesive has been effectively cross-linked with the skull. With the help of a 0.031-inch drill bit, carefully drill two boreholes bilaterally into the skull at 5,000 rotations per minute, or RPM, avoiding drilling into the brain. Apply a drop of saline to enhance the drilling of the burr holes. For implantation of hippocampal depth electrodes, drill at 3 millimeters posterior and 3 millimeters lateral from bregma.

Drill one burr hole for the reference electrode above the cerebellum, behind the lambda at 6 millimeters posterior and 0 millimeters lateral from bregma. Next, mount the six-pin pedestal with assembled electrodes into the electrode holder on a stereotactic frame. By aligning the electrodes above the corresponding burr holes, slowly lower and navigate the headset to locate the two bipolar electrode tips right on top of the left and the right hippocampal burr holes, and if needed, adjust the reference electrode to hover above hole, over the cerebellum.

When the hippocampal twist electrodes are right above the holes, zero the z-axis, and slowly lower the electrode to minus three millimeters into the right and left hippocampus, and guide the reference electrode into the hole above the cerebellum. Prepare the dental cement by mixing the powder and liquid in a mixing bowl, then cover the skull surface, the electrodes, and the space between the skull surface and the bottom of the pedestal with dental cement.

Once the cement dries and hardens, detach the electrode holder from the stereotactic arm, raise arm, and remove the holder from the pedestal. After administering the mouse subcutaneously with ketoprofen and normosol, remove the animal from the stereotactic frame to move the animal onto the heated pad in the vivarium cage. Once fully awake, return the single animal to the vivarium cage, feed the animal with soft food, and monitor the weight loss daily up to 72 hours post-surgery.

Related Videos

Cochlear Implant Surgery and Electrically-evoked Auditory Brainstem Response Recordings in C57BL/6 Mice

09:06

Cochlear Implant Surgery and Electrically-evoked Auditory Brainstem Response Recordings in C57BL/6 Mice

Related Videos

14.8K Views

Using a Bipolar Electrode to Create a Temporal Lobe Epilepsy Mouse Model by Electrical Kindling of the Amygdala

09:49

Using a Bipolar Electrode to Create a Temporal Lobe Epilepsy Mouse Model by Electrical Kindling of the Amygdala

Related Videos

3.2K Views

Calcium Imaging In Electrically Stimulated Flat-Mounted Retinas

07:25

Calcium Imaging In Electrically Stimulated Flat-Mounted Retinas

Related Videos

2.7K Views

High-density EEG Recordings of the Freely Moving Mice using Polyimide-based Microelectrode

06:59

High-density EEG Recordings of the Freely Moving Mice using Polyimide-based Microelectrode

Related Videos

38.2K Views

Implantation of Electrodes into a Mouse Cortex for Electrocorticographic Recordings

03:59

Implantation of Electrodes into a Mouse Cortex for Electrocorticographic Recordings

Related Videos

1.1K Views

Implanting a Wireless Bidirectional Microelectrode System in a Rat Brain

03:39

Implanting a Wireless Bidirectional Microelectrode System in a Rat Brain

Related Videos

717 Views

Recording Brain Electrical Activity in Behaving Mice Using Multi-Shank Linear Silicon Probes

03:22

Recording Brain Electrical Activity in Behaving Mice Using Multi-Shank Linear Silicon Probes

Related Videos

752 Views

Implanting an On-Head Electrode System in a Rat Model for Real-Time Seizure Detection

05:12

Implanting an On-Head Electrode System in a Rat Model for Real-Time Seizure Detection

Related Videos

718 Views

Implanting an Electrode Array and Optic Fiber into the Mouse Hippocampus

02:51

Implanting an Electrode Array and Optic Fiber into the Mouse Hippocampus

Related Videos

884 Views

Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy

11:54

Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy

Related Videos

27.1K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code