Juxtacellular Recording and Staining for Precise Mapping of Neural Activity in an Awake Rat

0 views • 2:54 min • June 18th, 2025

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Start with a restrained, awake rat in an experimental jig, with its head firmly fixed in place.

Open the previously implanted recording chamber and remove the silicone gel covering.

Clear away any regrown tissue to access the brain.

Add a drop of saline to maintain hydration.

Next, attach a pre-filled recording pipette containing Chicago blue dye to a micromanipulator.

Lower the pipette into the recording chamber until it reaches the target brain region.

The pipette makes contact with the neuron and records the signals from the neuron without penetrating it.

Listen to these neuronal signals as audible clicks, then deliver electrical pulses through the pipette.

These pulses inject the dye adjacent to the neuron, enabling precise staining of the target brain region.

These juxtacellular recording and staining techniques precisely visualize the recording site and allow accurate mapping of neural activity to brain anatomy.

Place the rat in the cloth sock, and transfer the cloth sock into a rigid tube on an appropriate experimental jig. Attach the head restraining plate on the rat to the corresponding piece on the jig. Next, place an 832 nut on the head restraining bolt that is implanted on the rat.

Subsequently, screw in a threaded stainless steel rod to the head bolt. After that, open the recording chamber, and remove the silicone gel. Clean the craniotomy using fine forceps if tissue has regrown in the craniotomy. Use isoflurane anesthesia during this process, if necessary.

Next, attach the pipette to the motorized micromanipulator. Move the pipette to the desired recording location in the anterior, posterior, and medial lateral axes. Then advance the pipette ventrally through the dura until it is approximately 500 micrometers dorsal to the intended recording location. Slowly advance the pipette while listening for spiking events on an audio monitor of the amplified voltage recorded. Once spiking events are identified, continue to move the pipette about 0 to 100 micrometers until the positive voltage deflections are greater than approximately 500 microvolts.

To label the recording site, set the current source to negative 4 microamps with two second pulses at 50% Duty cycle. And pass the current for four minutes to iontophoretic inject Chicago Sky Blue through the pipette.

10:46

Acute In Vivo Electrophysiological Recordings of Local Field Potentials and Multi-unit Activity from the Hyperdirect Pathway in Anesthetized Rats

Related Videos

0 Views

09:58

Syringe-injectable Mesh Electronics for Stable Chronic Rodent Electrophysiology

Related Videos

0 Views

05:45

Recording Large-scale Neuronal Ensembles with Silicon Probes in the Anesthetized Rat

Related Videos

0 Views

14:06

Preparation of an Awake Mouse for Recording Neural Responses and Injecting Tracers

Related Videos

0 Views

02:36

In Vivo Recording of Intracellular Signals from a Single Neuron

Related Videos

0 Views

04:42

In Vivo Electrophysiological Recordings of Brain Activities from Multiple Sites in Rats

Related Videos

0 Views

03:13

Simultaneous Imaging of Microglial Dynamics and Neuronal Activity in an Awake Mouse

Related Videos

0 Views

06:36

Inhibition of Neuronal Activity and Its Detection Using Electrophysiology in a Rat

Related Videos

0 Views

10:36

Juxtasomal Biocytin Labeling to Study the Structure-function Relationship of Individual Cortical Neurons

Related Videos

0 Views

08:41

Juxtacellular Monitoring and Localization of Single Neurons within Sub-cortical Brain Structures of Alert, Head-restrained Rats

Related Videos

0 Views

Last updated: 18 July 2026