Sequential Application of Glass Coverslips to Assess the Compressive Stiffness of the Mouse Lens: Strain and Morphometric Analyses

6.8K views

Cited by 28

07:56 min

May 3rd, 2016

10.3791/53986-v

May 3rd, 2016

6.8K views

Age-related increases in eye lens stiffness are linked to presbyopia. This protocol describes a simple, cost-effective method for measuring mouse lens stiffness. Mouse lenses, like human lenses, become stiffer with age. This method is precise and can be adapted for lenses from larger animals.

Explore More Videos

Mouse Lens Stiffness

Chapters in this video

0:05

Title

1:00

Lens Dissection

2:24

Stiffness Measurements

4:51

Lens Nucleus Measurement and Image Analysis

5:51

Results: Axial and Equatorial Strain-load Curves and Morphological Characteristics of 2,4, and 8-month-old WT Mouse Lenses

7:05

Conclusion

Related Videos