Advantages of the retinal explant model
Mouse retinas were removed and spread on filter paper. After a stable culture, the retinal explants were treated with iron blocks. The iron blocks were less likely to shift on the flattened retinas, allowing more precise localization of the foreign body beds than in the animal model, in which the retinal surface is curved and the eyeball can rotate (Figure 1). During the experiment, parameters including the composition of the culture medium, the size, shape, and position of the iron blocks, and the culture duration could be precisely controlled. All explants were maintained under the same environmental conditions. The model construction experiments could be repeated. This method, therefore, provides a controllable and repeatable approach for studying retinal damage caused by IOFBs.
Microscopic observation of the retinal explant model
Before and after treatment of the retinal explants, changes in retinal appearance, including color, texture, and overall morphology, could be directly observed under a microscope in real time. An iron block was placed on one corner of the retinal explant for 24 h. Microscopic observation showed that the retinas in the Fe group became brownish-yellow, differing from their appearance before iron placement and from those in the control group. Notably, retinal regions near the Fe-Bed showed deep brown discoloration (Figure 2).
Microscopic morphological analysis of the retinal surface
SEM showed that 24 h of iron block treatment caused changes in the retinal surface over the Fe-Bed. In the wide-view SEM images, the retinal surface in the control group remained dense and compact without vascular exposure (Figure 3A), whereas the Fe group showed a rough retinal surface with exposed blood vessels (Figure 3B). The corresponding higher-magnification images showed the same findings in the control (Figure 3C) and Fe (Figure 3D) groups. In addition, a particle approximately 20 µm × 25 µm was observed in the Fe-Far region of one sample, with loose edges and extensive surrounding areas showing loose infiltration traces (Figure 3D).
Energy spectrum analysis of elements on the retinal surface
EDS was performed to analyze retinal surface elemental distribution in the control and Fe groups (n = 3 per group). Elemental mapping first showed that Fe was undetectable in the control retinal regions but was present at the foreign body bed and in the distal retinal region of the Fe group (Figure 4). Face-total EDS spectra and the corresponding quantitative parameters further showed the elemental profiles of the control region, Fe-Bed, and Fe-Far (Figure 5). Statistical comparison of elemental k-ratios between the control and Fe groups was then performed (Figure 6).
Compared with the control group, the Fe group showed significantly lower k-ratio values of C (0.574 ± 0.064 vs. 0.316 ± 0.116, P = 0.028) and S (0.015 ± 0.002 vs. 0.011 ± 0.001, P = 0.039). By contrast, the k-ratios of K, Ca, and Fe were significantly higher in the Fe group (K: 0.001 ± 0.002 vs. 0.013 ± 0.006, P = 0.046; Ca: 0.001 ± 0.003 vs. 0.014 ± 0.006, P = 0.046; Fe: 0 ± 0 vs. 0.082 ± 0.040, P = 0.024). No significant differences were found in the k-ratios of O (P = 0.204), Na (P = 0.179), or P (P = 0.05) between the two groups. Student’s t-test was used for C, O, Na, and S, and the Mann-Whitney U test was used for P, K, Ca, and Fe.

Figure 1: Experimental procedure. Retinal explants were cultured, with the experimental group treated with iron blocks for 1 day and the control group receiving blank treatment. Microscopic observation, electron microscopy pretreatment, field-emission scanning electron microscopy (FE-SEM), and energy-dispersive spectroscopy (EDS) were subsequently performed. Please click here to view a larger version of this figure.

Figure 2: White-light images of retinal explants under the microscope. Representative images are shown. The retinal explant was shaped like a four-leaf clover, with each leaflet labeled clockwise. In the control group (A, B), the four leaflets were labeled C-a, C-b, C-c, and C-d. In the Fe group (C, D), the four leaflets were labeled Fe-a, Fe-b, Fe-c, and Fe-d. The iron block was placed on the Fe-a leaflet. Compared with the retinal explant before treatment (C), the retinal explant became brownish-yellow 1 day after iron block treatment, particularly around the iron block (D, Fe-a). At the corresponding time point, no significant change was observed in the retinal explants of the control group (A, B). Please click here to view a larger version of this figure.

Figure 3: Iron block foreign bodies cause changes in retinal surface morphology. Representative images are shown. A wide-view SEM image of a retinal explant in the control group following blank treatment is shown in (A), with the corresponding color-marked and digit-numbered SEM images shown in (C). A wide-view SEM image of a retinal explant in the Fe group following iron block treatment is shown in (B), with the corresponding color-marked and digit-numbered SEM images shown in (D). Compared with the control group, the retinal surface in the Fe group, particularly at the foreign body bed, appeared rough, with exposed blood vessels and particle adhesion. SEM, scanning electron microscopy; Fe-Bed, foreign body bed position of the iron block; Fe-Far, region 2–3 mm from the foreign body bed on the lateral leaflet of the opposite side. Please click here to view a larger version of this figure.

Figure 4: SEM-EDS elemental mapping of the retinal surface in the control and Fe groups. Representative images are shown. SEM images and corresponding EDS elemental distribution maps are shown for the midperipheral retina in the control group (Control), the foreign body bed (Fe-Bed), and the distal retina (Fe-Far) in the Fe group. Different colors in the EDS maps represent different elements. Fe was not detected in the control group but was detected on the retinal surface in the Fe group. The distribution patterns of K and Ca were similar to that of Fe. SEM, scanning electron microscopy; EDS, energy-dispersive spectroscopy; Fe-Bed, foreign body bed position of the iron block; Fe-Far, region 2–3 mm from the foreign body bed on the lateral leaflet of the opposite side; Fe, iron; O, oxygen; P, phosphorus; S, sulfur; Na, sodium; C, carbon; K, potassium; Ca, calcium. Please click here to view a larger version of this figure.

Figure 5: Face-total EDS spectra and corresponding parameters. Representative images with corresponding data are shown. The face-total EDS spectrum and parameter list of the midperipheral retina in the control group are shown in (A) and Table-a, respectively. The face-total EDS spectrum and parameter list of the foreign body bed in the Fe group are shown in (B) and Table-b, respectively. The face-total EDS spectrum and parameter list of the distal retina in the Fe group are shown in (C) and Table-c, respectively. The parameter lists include detected elements, line type, apparent concentration, K-ratio, wt%, wt% sigma, at%, and standard sample label. EDS, energy-dispersive spectroscopy; Fe-Bed, foreign body bed position of the iron block; Fe-Far, region 2–3 mm from the foreign body bed on the lateral leaflet of the opposite side; Fe, iron; O, oxygen; P, phosphorus; S, sulfur; Na, sodium; C, carbon; K, potassium; Ca, calcium. Line type indicates the characteristic X-ray spectral line. The K-ratio is the ratio of the net count of characteristic X-rays from the element in the sample to that of the standard sample under identical conditions. wt% indicates the weight percentage, or mass fraction, of the element after matrix correction. wt% sigma indicates the standard deviation of the weight percentage, reflecting the statistical error of the quantitative result. at% refers to the atomic proportion of a specific element relative to the total atoms of all detected elements in the test sample. The x-axis represents X-ray energy in kilo-electron-volts (keV), and the y-axis represents signal intensity in counts per second per electron volt (cps/eV). Please click here to view a larger version of this figure.

Figure 6: Comparison of elemental K-ratios on the retinal surface between the control and Fe groups. Elemental K-ratios at the midperipheral retinal region in the control group (Blank) were compared with those at the foreign body bed (Fe-Bed), located in the midperipheral region, in the Fe group (Iron block). n = 3 mice per group; data were obtained from one independent biological experiment. Compared with the control group, the K-ratios of C and S after iron block treatment were significantly decreased, whereas the K-ratios of K, Ca, and Fe were significantly increased. Fe was not detected in the examined region of the control group. Elemental K-ratios are presented as mean ± standard deviation for Blank vs. Iron block, with corresponding P values: C, 0.574 ± 0.064 vs. 0.316 ± 0.116 (P = 0.028); O, 0.065 ± 0.016 vs. 0.089 ± 0.021 (P = 0.204); Na, 0.007 ± 0.002 vs. 0.012 ± 0.005 (P = 0.179); P, 0.009 ± 0.001 vs. 0.048 ± 0.021 (P = 0.05); S, 0.015 ± 0.002 vs. 0.011 ± 0.001 (P = 0.039); K, 0.001 ± 0.002 vs. 0.013 ± 0.006 (P = 0.046); Ca, 0.001 ± 0.003 vs. 0.014 ± 0.006 (P = 0.046); and Fe, 0 ± 0 vs. 0.082 ± 0.040 (P = 0.024). Statistical analyses of elemental K-ratios between the two groups were performed using Student’s t-test for C, O, Na, and S and the Mann-Whitney U test for P, K, Ca, and Fe. Fe, iron; O, oxygen; P, phosphorus; S, sulfur; Na, sodium; C, carbon; K, potassium; Ca, calcium; ns, P ≥ 0.05; *P < 0.05. Please click here to view a larger version of this figure.
Image-processing statement
All micrographs were subjected only to uniform cropping and layout arrangement; no selective adjustments to brightness or contrast were applied. EDS intensity scales were not modified post-acquisition.
DATA AVAILABILITY:
The Data Availability Statement has been updated in the revised manuscript. The supplementary materials have been uploaded to Zenodo and are available at: https://doi.org/10.5281/zenodo.22052770.
| Problem | Possible Cause | Solution |
| During culture, the retinal explant may detach from the Whatman filter paper. | During construction of the retinal explant model, the retina was not fully flattened or sufficiently dried. | Ensure that the retina is cut uniformly with sufficient length into a four-leaf-clover shape so that it can lie completely flat on the Whatman filter paper. Appropriately extend the drying time to approximately 3 min and use a larger piece of ordinary filter paper. |
| Local folding and curling of the retinal explant may occur during culture. | Residual vitreous body was not completely removed during retinal separation. | During retinal separation, completely remove the vitreous body before cutting toward the limbus. Maintaining retinal attachment during vitreous removal allows more complete clearance. |
| The part of the retinal inner limiting membrane not in contact with the iron block may show severe mechanical damage. | The retina was damaged by forceps during the experiment. | Use atraumatic, non-toothed forceps and avoid clamping the inner surface of the retina. |
| The dehydrated retinal explant may curl severely. | The Whatman filter paper was too thin or the cutting size was too small. | When trimming the specimen, remove only the irregular edges and do not separate the Whatman filter paper from the retina. |
| During SEM morphological imaging, some images may appear blurry or distorted or may show abnormal bright areas. | The explant is non-conductive. Under electron-beam irradiation, charge accumulation on the explant surface can cause electron-beam deflection, resulting in blurry or distorted images or abnormal bright areas. | Ensure uniform platinum coating of the sample. |
Table 1: Common problems, possible causes, and solutions during retinal explant preparation and SEM-EDS analysis. The table summarizes frequently encountered experimental issues during retinal explant culture, fixation, dehydration, drying, sample mounting, SEM imaging, and EDS analysis, together with plausible causes and corresponding troubleshooting measures.