Although following these protocols will usually result in high quality images, it is important to consider a few key issues in order to obtain accurate and consistent data from imaging studies. Luminescence images should be acquired that have counts from 600 to 60,000 to ensure that the signal is above background and the camera is not saturated. If signal obtained is less than 600 the exposure conditions should be adjusted to increase counts. If signal obtained is over 60,000 the camera is saturated in some regions. When the camera is saturated, quantification should not be attempted in saturated regions, though it is still possible and sometimes necessary in non-saturated regions. In addition, 3D reconstruction cannot be carried out accurately when saturated a regions is included within the region being used for the mask for the reconstruction. The adjustment of exposure time, binning and F/stop for image acquisition as well as modification of the imaging region or animal position can control the signal obtained and allow quantitative analysis of data. Thus, in many experiments it is helpful to consistently image animals under multiple exposure conditions to ensure that at least one set of images will be within the required limits to allow quantitative analysis.
It is important to remember that expression of any reporter gene can affect virulence, making it necessary to carry out pilot studies to evaluate potential impacts on fitness in recombinants strains that are to be used for imaging. This is one of the limitations of bioluminescent imaging, since it requires expression of foreign genes in the bacteria. This may often be overcome through the use of optimized constructs that use the appropriate codon usage for the bacterial species to be studied, titration of expression levels for reporter genes to reduce impact on metabolism or examination of multiple luminescent reporter systems that may differ in their impact on fitness.
Another primary variable for imaging studies with infectious agents is the level of signal produced by the agent being imaged. Since there are differences in the threshold of detection for each agent in animals as compared to in vitro, it is recommended that pilot studies using multiple infectious doses to optimize agent numbers prior to carrying out more extensive experiments. The bioluminescent reporters themselves should also be optimized for transcription, translation and low toxicity, to ensure that the level of signal produced is as high as possible. Optimization of reporters can be accomplished in most cases in vitro, but the wavelength of light emission will also impact the ability light produced by optimal reporters to penetrate mammalian tissue, making it important to also evaluate different reporters directly in animals. Although each animal can be followed individually, which controls for a great deal of the variability between animals, it is still necessary to include sufficient animals to allow statistical significance between groups to be determined. Usually, animal numbers should be 4 - 6 per group, allowing differences as low as two-fold between groups to be observed in many cases. Lastly, the inoculation route and accuracy of delivery to the appropriate tissues and of precise agent numbers will help to ensure consistent results by reducing overall variability between animals.
The spectral properties of the bioluminescence produced is also an important factor affecting the ability to image infections in vivo. In mammalian tissues, light of wavelengths less than 600 nm are largely absorbed by hemoglobin, a major component of mammalian tissue. The depth of penetration for bioluminescence wavelengths drastically increases for wavelengths longer than 600 nm8,12. Both CBRluc and FFluc produce bioluminescence with a broad wavelength, including over 600 nm, making these luciferases nearly ideal reporters for in vivo imaging, even in deep tissues including lungs and liver7-8.