A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Hydrophilic Interaction Liquid Chromatography: A Technique to Separate Hydrophilic Polar Analytes Using Hydrophilic Beads

2.3K views

July 8th, 2025

In This Article

Abstract

Source: Liu, D., et al. Immunoglobulin G N-Glycan Analysis by Ultra-Performance Liquid Chromatography. J. Vis. Exp. (2020).

This video demonstrates the principle of separation of hydrophilic polar compounds using hydrophilic interaction liquid chromatography. This technique helps in the purification of various polar analytes, including N-glycans.

Protocol

1. Hydrophilic interaction chromatography and analysis of glycans

  1. Conditioning of UPLC instruments and preparation of mobile phases
    1. Prepare mobile phases including solvent A: 100 mM ammonium formate (pH = 4.4), solvent B: 100% acetonitrile, solvent C: 90% ultra-pure water (10% methanol), and solvent D: 50% methanol (ultra-pure water).
    2. Open the software to control the mobile phases.
    3. Wash UPLC instruments at flow rate of 0.2 mL/min (50% solvent B and 50% solvent C) balancing for 30 min, then at a flow rate of 0.2 mL/min (25% solvent A and 75% solvent B) balancing for 20 min, then a flow rate of 0.4 mL/min balancing.
  2. Dissolve the N-glycans prelabeled with 2-aminobenzamide (2-AB) in 25 µL of a mixture of 100% acetonitrile and ultra-pure water at a 2:1 ratio (v/v). Then, centrifuge at 134 × g for 5 min (4 °C) and load 10 µL of the labeled N-glycans into the UPLC instruments.
  3. Separate the labeled N-glycans at flow rate of 0.4 mL/min with a linear gradient of 75% to 62% acetonitrile for 25 min. Then, perform an analytical run by dextran calibration ladder/glycopeptide column on a UPLC at 60 °C (here, samples were kept at 4 °C prior to injection).
  4. Detect N-glycan fluorescence at excitation and emission wave lengths of 330 nm and 420 nm, respectively.
  5. Integrate the glycans based on peak position and retention time.
  6. Calculate the relative value of each Glycan Peak (GP)/ all Glycan Peaks (GPs) (percentage, %) as follows: GP1: GP1/GPs*100, GP2: GP2/GPs*100, GP3: GP3/GPs*100, etc.

Access restricted. Please log in or start a trial to view this content.

Disclosures

No conflicts of interest declared.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
2-aminobenzamide, 2-ABSigma, China
AcetonitrileHuihai Keyi Technology Co., Ltd, China
Ammonium formateBeijing Minruida Technology Co., Ltd.
Dextran Calibration Ladder/Glycopeptide columnWatts technology Co., Ltd, China
Empower 3.0Waters technology Co., Ltd, America
GlycoProfile 2-AB Labeling kitSigma, China
MethanolHuihai Keyi Technology Co., Ltd, China
Milli-Q pure water meterMillipore Co., Ltd, America202-2AB
Transfer liquid gunSmer Fell Science and Technology Co., Ltd, ChinaAdvantage A10
Ultra-low temperature refrigeratorThermo Co., Ltd, AmericaPB-10
Ultra-performance liquid chromatographyWatts technology Co., Ltd, China
Vacuum PumpWatts technology Co., Ltd, China4672100, 0.5-10μl & 10-100μl & 20-200μl & 1000μl

Tags

HILIC TechniqueN-Glycan AnalysisUPLC SeparationFluorescent DetectionMobile Phase GradientAqueous Layer FormationDextran Calibration