Liquid Phase Isoelectric Focusing: An Electrophoresis Technique to Separate Bioactive Molecules from Crude Gymnema sylvestre Extract

0 views3:11 min • July 8th, 2025

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Begin with a pre-assembled isoelectric focusing, IEF cell - a liquid-phase electrophoresis unit. This column is a compartmentalized, horizontal porous chamber with distinct positive and negative terminals at the ends.

Now, take the plant extract containing a complex mixture of differently charged components with varying isoelectric points, pI - a pH where the net charge on a molecule is zero.

The extract is supplemented with ampholytes of variable charges that facilitate the fractionation of sample components later.

Load the sample into the loading ports of the column. Currently, the IEF column has a constant pH. Next, apply high voltage to initiate the electrophoresis.

Under the electric field, the soluble ampholytes migrate toward oppositely charged electrodes and establish a linear pH gradient across the column. Sample components start migrating through the liquid phase pH gradient, and ones positioned at pH below their pI carry a net positive charge.

These migrate toward the negative electrode until the components reach their pI, where their charge neutralizes, and migration stops. Similarly, components at pH above their pI migrate toward the positive electrode and stop when they reach their pI. This separates sample components based on their pI into focused compartments. Harvest the purified fractions for further analysis.

Add 0.6 grams of Gymnema sylvestre plant extract to 60 milliliters of distilled water. Dissolve the plant extract by mixing in a roller tube for five minutes.

To remove the insoluble particles, centrifuge the solution at 10,000 x g for five minutes. Transfer the supernatant to a 150-milliliter glass beaker, and add ampholyte to create a 1% solution by volume, approximately 0.6 milliliters.

Using a 50-milliliter syringe, with a 1.5-inch, 19-gauge blunt-end needle, load the solution into the IEF cell through the sample collection ports. Then, remove the cell from the stand, and tap the electrode chamber to dislodge and remove any bubbles.

Connect the unit to the cooling water. With the power supplied at constant 15 watts, begin fractionation. Run the IEF unit until the voltage reaches a constant value, approximately three hours.

After pressing the Harvest ON button, align the fraction collector pins with the collection ports. Push the pins through the sealing tape to begin collecting the Gymnema sylvestre fractions.

08:31

Total Protein Extraction and 2-D Gel Electrophoresis Methods for Burkholderia Species

Related Videos

0 Views

07:53

Proteomic Profiling of Macrophages by 2D Electrophoresis

Related Videos

0 Views

07:58

Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method

Related Videos

0 Views

08:17

Electrophoretic Separation of Proteins

Related Videos

0 Views

10:32

On-chip Isotachophoresis for Separation of Ions and Purification of Nucleic Acids

Related Videos

0 Views

02:59

Anion-Exchange Chromatography-Based Protein Purification: A Separation Technique to Isolate a Protein of Interest From Dialyzed Bacterial Lysate Based on Net Charge

Related Videos

0 Views

07:37

Two-Dimensional Polyacrylamide Gel Electrophoresis: A Separation Technique for Analysis of Proteins in Complex Protein Mixture Based on Charge and Molecular Weight

Related Videos

0 Views

10:07

Identification of Post-translational Modifications of Plant Protein Complexes

Related Videos

0 Views

09:57

Separation of Bioactive Small Molecules, Peptides from Natural Sources and Proteins from Microbes by Preparative Isoelectric Focusing (IEF) Method

Related Videos

0 Views

06:30

Efficient Purification of Elastin-Like Polypeptides (ELPs) from E. coli Using an Organic Solvent-based Extraction and Precipitation Method

Related Videos

0 Views

Last updated: 1 August 2026