Mobility Shift Affinity Capillary Electrophoresis: A Method to Analyze Sample-Ligand Interactions Depending on Differential Migration of Protein-Ligand Complexes

0 views • 3:23 min • July 8th, 2025

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Ligands, such as metal ions, bind non-covalently to a specific protein, forming a protein-metal ion complex. This binding alters the overall charge of the protein, which allows for the characterization of these complexes using affinity capillary electrophoresis.

To begin, take a thin, pre-conditioned glass capillary with charged silanol groups on the inner surface. Rinse the capillary with EDTA solution. EDTA is a chelating agent that removes any metal ion impurities. Now, hydrodynamically inject the sample solution containing the desired protein into the capillary from its positive end or anode. 

Apply a high voltage to create an electro-osmotic flow, forcing the proteins in their native conformation with inherent charges to move inside the capillary toward the cathode. Record the migration pattern of unbound proteins from the capillary.

Next, introduce a specific ligand solution into the capillary along with the protein samples, and apply the same voltage. Inside the capillary, the ligand molecules bind non-covalently to the target protein, forming complexes.

This induces a conformational change in the proteins, leading to an alteration in their inherent charges and, impacting the charge-to-size ratio. These changes modulate their interactions with the charged surface of the capillary, causing them to flow differently compared to the unbound protein.

Record these changes in the electrophoretic mobility, which correlate with the strength of the protein-ligand interaction.

After preparing the method for the measurements without ligands, prepare the method for the measurements with ligands, by first using 0.1 molar EDTA solution to rinse the capillary at 2.5 bar for 1 minute. Then, use deionized water to rinse the capillary. Next, equilibrate the capillary by using ligand solution to rinse it at 2.5 bar for 1.5 minutes.

Then, inject the acetanilide solution at 0.05 bar for 6 seconds, and change the inlet and outlet vials to the ligand-containing buffer vials. Apply 0.05 bar for 2.4 seconds, in order to push the acetanilide solution further in from the tip of the capillary. Apply 10.0 kilovolts for 6 minutes, and detect the acetanilide peak at a wavelength of 200 nanometers.

After rinsing the capillary with EDTA, deionized water, and the ligand solution as before, inject the protein sample, and change the inlet and outlet vials to fresh ligand-containing buffer vials. Ultimately, repeat taking measurements with and without ligands.

11:06

Structural Characterization of Mannan Cell Wall Polysaccharides in Plants Using PACE

Related Videos

0 Views

08:29

Proteome-wide Quantification of Labeling Homogeneity at the Single Molecule Level

Related Videos

0 Views

11:04

Ion Mobility-Mass Spectrometry Techniques for Determining the Structure and Mechanisms of Metal Ion Recognition and Redox Activity of Metal Binding Oligopeptides

Related Videos

0 Views

04:38

Differential Radial Capillary Action of Ligand Assay: A High-Throughput Technique to Identify Bacterial Nucleotide Second Messenger-Binding Intracellular Proteins

Related Videos

0 Views

04:31

Electrophoretic Mobility Shift Assay for Detection of Transcription Factor-DNA Complexes

Related Videos

0 Views

13:26

Determination of Protein-ligand Interactions Using Differential Scanning Fluorimetry

Related Videos

0 Views

09:58

An Optimized Protocol for Electrophoretic Mobility Shift Assay Using Infrared Fluorescent Dye-labeled Oligonucleotides

Related Videos

0 Views

07:54

Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis

Related Videos

0 Views

Last updated: 4 July 2026