Waiting
Procesando inicio de sesión ...

Trial ends in Request Full Access Tell Your Colleague About Jove
Experiment
JoVE Encyclopedia of Experiments
Encyclopedia of Experiments: Biological Techniques

Se requiere una suscripción a JoVE para ver este contenido. Inicie sesión o comience su prueba gratuita.

Reporter Gene Repression Assay to Study Translational Regulation of a Target Gene

 

Reporter Gene Repression Assay to Study Translational Regulation of a Target Gene

Article

Transcript

Transform the prepared plasmids into chemically competent bacterial cells already containing an RBP-mCerulean plasmid. To save time, plate the cells using an 8-channel pipettor on 8-lane plates containing Luria-Bertani agar with relevant antibiotics. Colonies should appear in 16 hours at 37 degrees Celsius.

Select a single colony for each double transformant and transfer to 48-well plates containing 1.5 milliliters of LB with appropriate antibiotics. Grow the cells over a period of 18 hours at 37 degrees Celsius shaking at 250 RPM. Store the overnights' glycerol stocks at -80 degrees Celsius in 96-well plates.

In the morning, program the robot to warm 180 microliters of semi-poor medium, or SPM, in 96-well plates. Program the robot to prepare the inducer plate.

In a clean 96-well plate, prepare wells with SPM consisting of 95% BA and 5% LB. The number of wells corresponds to the desired number of inducer concentrations. Add C4-HSL to the wells in the inducer plate that will contain the highest inducer concentration.

Next, program the robot to serially dilute medium from each of the highest concentration wells into 23 lower concentrations ranging from 0 to 218 nanomolar. The volume of each inducer dilution should be sufficient for all strains.

To dilute the overnight strains, program the robot to dilute by a factor of 10 by mixing 20 microliters of bacteria with 180 microliters of SPM in 48-well plates. Then, dilute again by a factor of 10 by taking 20 microliters from the diluted solution into the pre-prepared strain plate suitable for fluorescent measurements.

Now, program the robot to add the diluted inducer from the inducer plate to the 96-well plates with the diluted strains according to the final concentrations. Shake the 96-well plates at 37 degrees Celsius for 6 hours. During that time, take measurements of the optical density or OD at 595 nanometers, as well as mCherry and mCerulean fluorescence via a plate reader every 30 minutes.

Read Article

Get cutting-edge science videos from JoVE sent straight to your inbox every month.

Waiting X
Simple Hit Counter