A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Fixed Volume-Intercept Approach for Serial Contractility Assessment with Closed-Chest Pressure-Volume Loops in a Porcine Model

291 views

⸱

DOI:

10.3791/70220

⸱

April 24th, 2026

 ,  ,  ,  ,  ,  ,  ,  , 

In This Article

Summary

This protocol aims to provide a feasible, closed-chest porcine protocol to serially quantify load-independent LV contractility by fixing V0 and computing single-beat Ees, eliminating repeated IVC occlusions to enhance safety and stability in hemodynamically fragile, acute experiments.

Abstract

The end-systolic pressure–volume relationship (ESPVR) is widely regarded as the gold standard, load-independent descriptor of left-ventricular (LV) contractility. Practically, ESPVR is often approximated as a straight line defined by its slope - end-systolic elastance (Ees), a direct index of contractile state - and its volume-axis intercept (V₀), the theoretical LV volume at zero pressure. In vivo, ESPVR is classically derived from serial inferior vena cava (IVC) occlusions performed with simultaneous LV pressure–volume (PV) catheter monitoring. However, in disease states such as cardiogenic shock, the requisite preload depletion may provoke reflex tachyarrhythmias and transient or sustained hemodynamic instability, limiting feasibility and interpretability. Thus, methods for in vivo assessment of inotropy during hemodynamically fragile states are warranted.

This protocol aims to describe a practical experimental model in which V₀ is determined once under stable baseline conditions and then held fixed for subsequent, single-beat Ees estimation from LV PV loops. This approach, detailed step-by-step for use in acute large-animal studies, allows continuous serial assessment of contractility without repeated IVC occlusions. In a porcine cardiogenic shock model, it reliably tracked load-independent changes in myocardial performance while avoiding arrhythmias and hemodynamic instability otherwise provoked by preload reduction. The method is therefore well suited for acute, closed-chest experiments in which the ventricular geometry remains unchanged, and contractility primarily modulates the ESPVR slope rather than its intercept. Nonetheless, the fixed-V₀ assumption represents a methodological simplification that introduces deliberate systematic error and should only be applied when repeated preload manipulation is impractical or unsafe. When structural remodeling, profound LV dilation, or marked thoracic pressure changes occur, V₀ must be re-estimated. Overall, this protocol provides a feasible and physiologically sound approach for serial contractility assessment in unstable large-animal models, balancing methodological rigor with experimental safety and practicality.

Introduction

Left ventricular (LV) contractility is the intrinsic ability of myocardium to generate pressure independent of loading conditions1,2,3. It is a critical determinant of cardiac stroke volume, cardiac output, and blood pressure. Hence, when suffering from acute myocardial ischemia, the heart may quickly lose contractility4. Thus, impaired myocardial contractility may cause acute heart failure and cardiogenic shock (CS)5. CS results in hypotension and inadequate organ perfusion, leading to high mortality (30%–50% in-hospital)....

Access restricted. Please log in or start a trial to view this content.

Protocol

This protocol is approved by the Danish Animal Research Inspectorate (permit no: 2023–15–0201–01466, issued on 19/06–2023). Female Danish Landrace pigs of approximately 60 kg were used. This procedure is terminal, and the animals were euthanized at the end of the study with a lethal dose of pentobarbital (0.25 mL/kg IV of 400 mg/mL) under deep general anesthesia. The reagents and the equipment used are listed in the Table of Materials.

1. Anesthesia and ventilation

  1. Pre-anesthetize the pig with intramuscular injection of anesthetic mix 1 mL/kg, containing 25 ....

Access restricted. Please log in or start a trial to view this content.

Results

The instructions above present a protocol to derive Ees on a single-beat basis, keeping the theoretical volume of zero pressure generation, V0, constant. This section presents data from two studies conducted in our lab. First, a separate pilot study was conducted to examine the development of V0 and Ees following CS induction. Second, in a large dataset of 30 pigs included in previously published studies, the ischemic model of CS is presented4.

Access restricted. Please log in or start a trial to view this content.

Discussion

This protocol describes a pragmatic, reproducible, and feasible strategy for serial, load-independent assessment of LV contractility, viable even in acute cardiac illness such as ischemic CS. The protocol uses a fixed volume-axis intercept, V0, to estimate Ees from single beats, avoiding repetitive IVC occlusions and thus lowering the risk of arrhythmias and hypotension during vulnerable cardiovascular conditions. The methodological novelty of the present protocol lies in the explicit combination of empiricall.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors declare that they have no conflicts of interest.

Acknowledgements

OKH is supported by Sophus Jacobsen’s Foundation, the Graduate School of Health at Aarhus University Faculty, and the Danish Cardiovascular Academy, which is funded by the Novo Nordisk Foundation (grant number NNF20SA0067242) and the Danish Heart Foundation. We extend our thanks to Kasper Lykke Wethelund (Aarhus University) and Halvor Guldbrandsen (Aarhus University) for their voluntary contribution to data acquisition.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
0.9% salineFresenius Kabi, Germany921046Microsphere suspension and flush
10 mL syringesBD, USABD Plastipak 302143Microsphere injection
12 Fr femoral venous sheathTerumo, JapanRadifocus Introducer IIFor IVC occlusion balloon insertion
20 G venous catheterBD, USABD Insyte 381223Ear vein IV access
7 Fr femoral arterial sheathTerumo, JapanRadifocus Introducer IIInvasive arterial pressure monitoring
8 Fr carotid arterial sheathTerumo, JapanRadifocus Introducer IIAccess for LV PV catheter
8 Fr jugular venous sheathTerumo, JapanRadifocus Introducer IIPulmonary artery catheter access
Contour PVA microspheresBoston Scientific, USAContour 355–500 µmInduction of ischemic cardiogenic shock
Coronary guide catheterBoston Scientific, USAJL 3.5 / JR 4.0Coronary access for microsphere injection
ECG electrodes (3-lead)Ambu, DenmarkBlueSensor PContinuous ECG monitoring
Endotracheal tube 7.5–8.0 mmSmiths Medical, UKPortex ETTTracheal intubation
Fentanyl (IV)Hameln Pharma, GermanyFentanyl HamelnContinuous IV analgesia
Fluoroscopy system--Catheter guidance
Heated blankets3M, USABair Hugger Warming UnitMaintenance of normothermia
HeparinLeo Pharma, DenmarkInnohepAnticoagulation if used
Iomeron contrast agentBracco Imaging, ItalyIomeron 350Coronary angiography and microsphere suspension
IVC occlusion balloon catheterFogarty / Edwards Lifesciences, USAFogarty Occlusion BalloonTemporary preload reduction
LabChart 8 Pro softwareADInstruments, New ZealandLabChart 8 ProPV loop acquisition and analysis
LV PV catheter (admittance)Millar Inc., USAMPVS Ultra PV Loop CatheterAdmittance-based LV pressure–volume measurement
Mechanical ventilatorGE Healthcare, USADatex Ohmeda S/5Positive pressure ventilation
MPVS ModuleADInstruments, New ZealandMPVS Ultra/DuoInterface for PV catheter
PowerLab data acquisition systemADInstruments, New ZealandPowerLab 16/35Signal acquisition
Propofol (IV)Fresenius Kabi, GermanyDiprivan / Propofol-LipuroContinuous IV anesthesia
Pulmonary artery catheter 7.5 FrEdwards Lifesciences, USASwan-Ganz 131HF7Thermodilution CO and PA pressure
Pulse oximeter--Peripheral oxygen saturation monitoring
Rectal temperature probe--Core temperature monitoring
Seldinger guidewiresTerumo, JapanRadifocus Guide Wire MVascular access
Sterile saline flushesFresenius Kabi, Germany0.9% NaClSheath flushing
Suture materialEthicon, USAVicryl 3-0Fixation of sheaths
Syringe pumpsBecton Dickinson (BD), USABD Alaris Continuous anesthetic infusion
Ultrasound system--Vascular access guidance
Urinary catheterTeleflex, USARüsch Foley catheterBladder drainage
Zoletil (tiletamine/zolazepam)Virbac, FranceZoletil 100Used for pre-anesthesia; mixed with butorphanol, ketamine, xylazine according to protocol

References

  1. Burkhoff, D., Mirsky, I., Suga, H. Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: A guide for clinical, translational, and basic researchers. Am J Physiol Heart Circ Physiol. 289 (2), H501-H512 (2005).
  2. Suga, H., Sagawa, K.

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

End Systolic PressureLeft Ventricular ContractilityCardiogenic ShockEnd Systolic ElastanceLoad Independent ContractilityIn Vivo AssessmentHemodynamic Instability

This article has been published

Video Coming Soon