Measuring Brain Glutamate Levels Under Anesthesia in Neonatal Piglets Using a Microelectrode Array

0 views4:01 min • July 8th, 2025

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

Secure an anesthetized neonatal piglet to a stereotaxic frame.

Make a midline incision to reveal the skull.

Remove a portion of the skull, then remove the dura to access the brain.

Fix a microelectrode array, or MEA to the stereotaxic frame.

The MEA consists of a rigid shaft and recording sites, including glutamate-sensitive sites coated with glutamate oxidase and sentinel sites coated with an inactive protein matrix.

Position the MEA vertically over the surgical site and place a pseudo-reference electrode under the scalp for a stable baseline voltage reference.

Insert the MEA into the brain region of interest and initiate measurement.

Glutamate oxidase on the recording sites converts extracellular brain glutamate to hydrogen peroxide, which undergoes electrochemical oxidation at the electrode surface, generating current.

The sentinel sites measure background noise.

Normalize the glutamate-sensitive site signals to the sentinel site signals to measure the brain glutamate levels under anesthesia.

To begin, create a 4- to 6-centimeter midline incision along the skull using caution to avoid scoring the skull with the scalpel. Once the incision is made, use gentle retraction and blunt dissection to elevate the scalp from the skull.

Next, gently scrub the skull with a gauze pad to remove any connective tissue and expose the suture lines. Then, determine the intended location for the craniotomy. If the area of interest remains obscured, further reflect the scalp.

Now, use a surgical drill to create a craniotomy window that is about 0.25 square centimeters overlying the structure of interest. Be careful not to injure the dura or the underlying brain. As needed, use fine surgical tools to excise the dura overlying the brain tissue. Use extreme care to avoid damaging the brain.

This experiment utilizes a previously described enzyme-based microelectrode array precoated with glutamate oxidase and electroplated with MPD. The microelectrode arrays have a 40-millimeter rigid shaft customized for use with piglets. Secure the metal arm to the micromanipulator, and then position the microelectrode array as vertically as possible over bregma.

Then, carefully lower the array as low as possible without touching the surface of the skull, noting the coordinates of bregma. Now, use a piglet brain atlas to determine the exact stereotaxic coordinates of the structure of interest. Then, reposition the microelectrode accordingly.

Next, place the pseudo-reference electrode under the scalp, ensuring contact with the animal. Now, slowly lower the microelectrode array into the brain to nearly the appropriate depth. For the final 2 millimeters of travel, use a hydraulic microdrive to gently lower the array into the structure of interest with minimal tissue trauma.

After the microelectrode array is positioned, wait 30 minutes to allow the electrodes to reach baseline. Then, take measurements for about three hours. If the piglet is to survive the experiment, close the incision after collecting data.

10:46

Using Enzyme-based Biosensors to Measure Tonic and Phasic Glutamate in Alzheimer's Mouse Models

Related Videos

0 Views

10:23

Measuring In Vivo Changes in Extracellular Neurotransmitters During Naturally Rewarding Behaviors in Female Syrian Hamsters

Related Videos

0 Views

12:56

Methodology for Biomimetic Chemical Neuromodulation of Rat Retinas with the Neurotransmitter Glutamate In Vitro

Related Videos

0 Views

04:34

In Vivo Real-Time Glutamate Monitoring Using an Enzyme-Coated Microelectrode Array

Related Videos

0 Views

08:30

A Method to Make a Craniotomy on the Ventral Skull of Neonate Rodents

Related Videos

0 Views

06:38

Use of a Piglet Model for the Study of Anesthetic-induced Developmental Neurotoxicity (AIDN): A Translational Neuroscience Approach

Related Videos

0 Views

08:03

Recording EEG in Freely Moving Neonatal Rats Using a Novel Method

Related Videos

0 Views

06:29

Electrophysiological Measurement of Noxious-evoked Brain Activity in Neonates Using a Flat-tip Probe Coupled to Electroencephalography

Related Videos

0 Views

08:23

Adaptation of Microelectrode Array Technology for the Study of Anesthesia-induced Neurotoxicity in the Intact Piglet Brain

Related Videos

0 Views

04:05

Noninvasive EEG Recordings from Freely Moving Piglets

Related Videos

0 Views

Last updated: 1 August 2026