DC/DC Boost Converter
  • 00:06Overview
  • 00:58Principles of Boost Converters
  • 05:01Board Setup
  • 07:12Boost Converter Testing with Variable Input
  • 08:38Boost Converter Testing with Variable Duty Ratio
  • 09:53Results
  • 11:02Applications
  • 11:56Summary

Conversor Boost DC/DC

English

Share

Overview

Fonte: Ali Bazzi, Departamento de Engenharia Elétrica da Universidade de Connecticut, Storrs, CT.

Os conversores boost fornecem uma solução versátil para intensificar as tensões DC em muitas aplicações onde uma tensão DC precisa ser aumentada sem a necessidade de convertê-la para AC, usando um transformador e, em seguida, corrigir a saída do transformador. Os conversores boost são conversores intensificadores que usam um indutor como um dispositivo de armazenamento de energia que suporta a saída com energia adicional, além da fonte de entrada DC. Isso faz com que a tensão de saída aumente.

O objetivo deste experimento é estudar diferentes características de um conversor de impulso. A capacidade de intensificação do conversor será observada sob o modo de condução contínua (CCM) onde a corrente do indutor não é zero. A operação de loop aberto com uma relação de serviço definida manualmente será usada. Será observada uma aproximação da relação entrada-saída.

Principles

Um conversor de impulso depende da energia armazenada no indutor, L,para fornecer energia para o lado de saída onde a carga é suportada, além de uma fonte DC ser a principal fonte de energia. O principal conceito por trás da operação do conversor de impulso é que um indutor vai virar sua polaridade de tensão para manter o fluxo de corrente. Como mostrado na Fig. 1(a) para um circuito simples de conversor de boost, quando o interruptor está ligado para um ciclo de trabalho D do período de comutação T,a tensão do indutor VL aumenta. Quando o interruptor está desligado, a corrente do indutor deve continuar fluindo e, portanto, a polaridade de tensão do indutor será invertida para adicionar à tensão de entrada Vem.

No entanto, quando o interruptor está ligado, a carga é curto-circuito e a tensão de saída é zero, o que não é desejado. Portanto, um diodo de bloqueio é adicionado no lado de saída, como mostrado na Fig. 1(b) para evitar que a carga seja curta-circuito. Este diodo ainda não resolve o problema da carga não vendo tensão quando o interruptor está ligado, de modo que um capacitor é adicionado como mostrado na Fig. 1(c) para fornecer a carga com corrente necessária durante o período em que o interruptor está ligado. Note que quando o interruptor está ligado, o diodo está desligado (viés inverso) e vice-versa. A tensão média da saída está, portanto, relacionada à tensão de entrada como: <Vfora>=Vem/(1-D).

Figure 1
Figura 1. Passos para a construção de um conversor de impulso

À medida que este experimento prossegue, será mostrado que a tensão média da saída aumenta à medida que o ciclo de serviço, D,aumenta. Isso é verdade, uma vez que a tensão de saída para a relação de tensão de entrada é inversamente proporcional a –D, e assim a tensão de saída e D têm uma correlação positiva.

Observe que a equação apresentada é para um conversor de impulso ideal, e pode parecer que um D=1 produzirá tensão de saída infinita, mas isso não é verdade. Na realidade, elementos parasitas e resistências no conversor de impulso fazem com que D fique limitado a cerca de 70-80% após o qual os efeitos parasiticos começam a dominar a operação do circuito e causam quedas significativas de tensão. Nesse ponto, a tensão de saída começa a diminuir à medida que a D aumenta. Com frequências de comutação mais altas, a ondulação de tensão na saída diminuirá, uma vez que os tempos de carregamento e descarga de tensão no capacitor tornam-se significativamente mais curtos com uma frequência de comutação reduzida.

Procedure

ATENÇÃO: Este experimento foi projetado para limitar a tensão de saída a menos de 50V DC. Use apenas as relações de serviço, frequências, tensão de entrada ou cargas que são dadas aqui. Este experimento utilizará a placa conversora DC-DC fornecida pela HiRel Systems. http://www.hirelsystems.com/shop/Power-Pole-Board.html Informações sobre a operação do conselho podem ser encontradas neste vídeo de coleções “Introdução ao Quadro HiRel”. O procedimento aqui mostrado se aplica a qualquer circuito simples de conversor de boost que possa ser construído em placas de proto, placas de pão ou placas de circuito impresso. 1. Configuração do quadro: Conecte a fonte de sinal ±12 no conector “DIN”, mas mantenha “S90” DESLIGADO. Certifique-se de que o seletor de controle PWM esteja na posição de loop aberto. Coloque a fonte de alimentação DC em 10 V. Mantenha a saída desconectada da placa por enquanto. Antes de conectar o resistor de carga, ajuste-o a 20 Ω. Construa o circuito mostrado em Fig. 2 usando a placa magnética MOSFET inferior, diodo superior e placa magnética BB. Observe o valor de indução mostrado no quadro. Conecte “RL”em “V1+” e “COM”. Observe que as conexões de entrada e saída são invertidas em comparação com as do experimento do conversor de buck. NUNCA Desconecte a carga durante o experimento, pois o conversor de impulso pode se tornar instável e causar danos à placa. Certifique-se de que a matriz de switches para seleção MOSFET (MOSFET inferior), seleção PWM e outras configurações estão corretas para alcançar um circuito funcional como na Fig. 2. Figura 2. Circuito de conversor boost 2. Ajustando a relação de dever e a frequência de comutação Conecte a sonda diferencial através do portão-fonte do MOSFET inferior. Ligue “S90”. Um sinal de comutação deve aparecer na tela do escopo. Ajuste o eixo de tempo do sinal para ver dois ou três períodos. Ajuste o potencialiômetro de frequência para alcançar uma frequência de 100 kHz (período de 10 μs). Ajuste o potencialiômetro da razão de serviço para atingir uma relação de 10% de imposto (no tempo de 1 μs). 3. Teste do conversor de impulso para entrada variável Conecte a fonte de alimentação DC de entrada, que já está definida em 10 V, a “V2+” e “COM”. Conecte a sonda diferencial para medir a corrente do indutor em “CS5”. Conecte a outra sonda através da carga. Certifique-se de que o conector do solo esteja conectado ao “COM”. Capture as formas de onda e meça a média de tensão de saída, a onda de corrente indutora e a corrente do indutor. Regisso registro das leituras de corrente de entrada e tensão na fonte de alimentação DC. Ajuste a tensão de entrada para 8 V, 12 V e 14 V e repita as etapas acima para cada uma dessas tensões. Desconecte a entrada de alimentação DC e ajuste sua saída para 10 V. 4. Teste do conversor de impulso para a relação de dever variável Conecte a sonda diferencial através do portão à fonte do MOSFET inferior. Conecte a outra sonda através da carga. Certifique-se de que o conector do solo esteja conectado ao “COM”. Conecte a fonte DC de entrada a “V2+” e “COM”. Capture as formas de onda e meça a média de tensão de saída e o tempo de tensão do portão para fonte (também a razão de serviço). Regisso registro das leituras de corrente de entrada e tensão na fonte de alimentação DC. Ajuste a relação de direitos para 20%, 40% e 60%. Repita as etapas acima para cada uma dessas três relações de serviço. Redefinir a relação de direitos para 10%. Desconecte a entrada de alimentação DC. 5. Teste do conversor de impulso para frequência de comutação variável Conecte a sonda diferencial através do portão à fonte do MOSFET inferior. Conecte a outra sonda através da carga com o conector do solo conectado ao “COM”. Conecte a fonte DC de entrada a “V2+” e “COM”. Ajuste a frequência de comutação para 70 kHz. Capture as formas de onda e meça a média de tensão de saída e o tempo de tensão do portão para fonte (também a razão de serviço). Regisso registro da corrente de entrada e leitura de tensão na fonte de alimentação DC. Ajuste a frequência de comutação para 40 kHz, 20 kHz e 10 kHz (ou mínimo possível se 10 kHz não puderem ser alcançados). Repita as etapas acima para cada uma dessas três frequências de comutação. Desligue a entrada de alimentação DC e “S90”, e desmonte o circuito.

Results

The boost converter output-input voltage relationship is proportional to the duty cycle in the sense that higher D will yield higher output voltages for a given input voltage. If the input voltage is Vinand the output voltage is Vout, Vout/Vin= 1/(1-D), where 0≤D≤ 100%. Therefore, for an input voltage of 10 V, Vout≈ 12.5 V for D = 20%, Vout 16.67 V for D= 40%, and Vout≈ 25 V for D = 60%.

Nevertheless, the output voltage will be lower than expected from the ideal relationship, which is linear with the duty ratio. The main reason is that the ideal converter model from which the Vout/Vin relationship can be derived does not account for non-idealities and voltage drops in the converter. Theoretically, as D→100%, Vout→∞; practically, a theoretical limit on the boosting capability is around 3-4x the input voltage, and after a certain level of D, the output voltage of the converter starts to drop rather than being boosted due to parasitic and non-ideal elements in a real converter.

Applications and Summary

Boost converters are very common in solar photovoltaic applications where the input voltage from the solar panel varies with weather conditions and available solar energy, and a boost converter can always boost from the PV panel voltage. Power factor correction to improve power quality as seen from the utility grid with power electronic loads which may require significant reactive power, e.g. motors, is another major application of boost converters.

Transcript

Boost converters are used in electronics to generate a DC output voltage that is greater than the DC input, therefore boosting up the supply voltage. Boost converters are often used in power supplies for white LEDs, battery packs for electric automobiles, and many other applications. A boost converter stores energy in an inductor’s magnetic field and transfers it to a load with a switching circuit. The transfer of energy from the inductor’s magnetic field enables the increase in DC output in a single stage. This video will illustrate the construction of a boost converter and investigate how changing the converter’s operating condition affects its output voltage.

This simple boost converter circuit consists of an input DC voltage source connected to an inductor and a switch. The switch may be a bipolar transistor, a MOSFET or, other similar electronic device that alternately connects and disconnects the inductor from the common line of the power supply. A blocking diode connects the inductor to a capacitor which filters the ripple in the output voltage. Increasing the capacitance decreases the ripple. For a sufficiently large capacitance the output becomes a steady DC voltage. A digital pulse train opens or closes the switch. The pulse has a duty ratio which is the ratio of the on time to the period. The duty ratio may vary from zero or increase up to one with more and more on time. When the pulse is on, the switch closes and the inductor is connected across the supply voltage. In this state, the inductor terminal connected to the output of the power supply has the higher potential and the terminal connected to the common has the lower potential. Now current flows through the inductor increasing linearly with time for sufficiently high switching frequencies. During this time the inductor voltage is defined to be positive because the slope of the current versus time is positive. The inductor stores energy proportional to the square of the current in its magnetic field. The longer the inductor is connected to the power supply, the more current increases and the more energy it stores. When the switch opens, current through the inductor must continue flowing in the same direction. This current also decreases because the inductor now gives up energy to the load. The inductor voltage becomes negative because the slope of current versus time is negative. As a result, the inductor’s polarity flips and now adds to input voltage “V in” producing a higher potential at the output. The circuit in this state, forward biases the diode and the inductor discharges current, some going to the load, and some going to the capacitor which then stores the charge. When the switch closes again the diode becomes reverse biased disconnecting the inductor from the output and preventing a short circuit of the load. During this time the inductor recharges and in its place the capacitor provides current to the load. This cycle of capacitor charging and discharging produces an average output voltage with some amount of ripple. At sufficiently high switching frequencies, the capacitor’s charge and discharge times are short and the output reaches a steady state voltage with relatively little ripple. This switching cycle repeats indefinitely and is the basis of boost converter operation. Ideally the average output voltage increases as the duty ratio increases and a duty ratio of one generates infinite voltage. However parasitic elements and resistances in the boost converter limit useful values of D to a maximum of about 0.7 or 0.8. If D is sufficiently large, parasitic effects dominate circuit operation and output voltage decreases even as D continues to increase. In the following experiments we will study how a boost converter steps up voltage in continuous conduction mode, also called CCM, a condition when the inductor operates at all times with non zero current.

The output voltage in this experiment is limited to 50 volts DC or less. Use only the specified duty cycles, frequencies, input voltages, and loads. These experiments utilize the HiRel Systems Power Pole Board which is designed for experimentation with different DC to DC converter circuit topologies. With signal supply switch S90 turned off, plug the +/- 12 volt signal supply into den connector J90. Set the PWM control selection jumpers J62 and J63 to the open loop position. Adjust the DC power supply to positive 10 volts but do not connect the power supply output to the board. Next build the circuit as shown with the lower MOSFET, the upper diode, and the BB magnetic board. Record the value of the inductor on the BB magnetic board. The load resistor is a power potentiometer. Use a multi meter to measure it’s resistance while adjusting it to 20 ohms. Then connect the potentiometer between terminals V1+ and COM. Set switch selector bank S30 as follows: PWM to bottom MOSFET, use onboard PWM, and switched load off. Connect the oscilloscope’s differential probe between terminal 16 which is the gate of the lower MOSFET and terminal 12 which is the source. Turn on switch S90. The pulse train that drives the MOSFET should appear on the scope’s screen. Select the scope’s time axis to display several periods of this wave form. Set frequency adjustment potentiometer RV60 to produce a switching frequency of 100 kilohertz. Set duty ratio potentiometer RV64 so the pulses have an on time of one microsecond which corresponds to a duty ratio of 0.1.

Connect the DC power supply to input terminals V2+ and COM. To measure the inductor current connect the differential scope probe between terminals CS5 and COM. To measure the voltage across load resistor RL, connect the other differential probe between terminals V1+ and COM. The output voltage should be a triangle wave. The upward ramps occur when the boost convertor switch is open and the inductor is transferring energy to the load. The downward ramps occur when the switch is closed, the inductor is disconnected from the output, and the capacitor is supplying energy to the load. The inductor current is a triangle wave which ramps up linearly during the on time of the pulse train, then ramps down linearly during the off time. The offset is the average current. Using the scope’s built in measurement functions, measure the mean value of the output voltage and the mean value of the inductor current. Repeat these steps with the input DC power supply set to eight, 12, and 14 volts. For a fixed duty ratio as the input voltage increases the output voltage of an ideal boost converter should increase proportionally.

This part of the experiment measures the duty ratio of the pulse train instead of the inductor current. Connect the scope probes between terminals 16 and 12 which are the gate and source of the lower MOSFET respectively. Connect the input DC power supply to terminals V2+ and COM. Like before, the output voltage is a triangle wave resulting from the inductor and capacitor alternately supplying current to the load. The gate source voltage of the MOSFET is a digital pulse train with a frequency of 100 kilohertz, a period of 10 microseconds, and an on time of one microsecond. Measure the mean value of the output voltage and the on time of the gate to source voltage along with the input current and voltage readings from the DC power supply. Repeat this test after adjusting duty ratio potentiometer RV64 so the pulse stream has an on time of two, four, and six microseconds, which correspond to duty ratios of 0.2, 0.4, and 0.6 respectively.

As duty ratio D increases, the output voltage of the boost converter also increases. Ideally if D has a value of 0.2 then an input of 10 volts generates an output of about 12.5 volts. If D is 0.4 then the output would be about 16.6 volts. If D is 0.6 then the output would be about 25 volts. In general, the output voltage is less than expected from the ideal relationship because parasitic elements create non ideal voltage drops and unaccounted energy loss. As the duty ratio approaches one, the theoretical output voltage becomes infinitely large. In reality, the output voltage is limited to about three or four times the input voltage and the influence of parasitic and non ideal components causes the output voltage to decrease after D becomes sufficiently high.

Boost converters generate an output voltage that is greater than the input voltage and many applications incorporate them to increase flexibility in the choice of power sources. The voltage from a solar panel changes with the position of the sun, weather conditions, and shade. Boost converters are commonly used to step up the variable output of a solar panel array to provide a consistent voltage to feed into an electrical grid. Battery powered systems are frequently used to power devices without the use of a power cord. In order to achieve the necessary higher output voltage, battery cells are often stacked. This can take up a lot of space if many cells are needed to reach the desired output. Instead, boost converters are used to step up the voltage while conserving space.

You have just watched Jove’s Introduction to Boost Converters. You should now understand how boost converters work and how adjusting input voltage, duty ratio, and frequency affects the output voltage. Thanks for watching.