Waiting
Login processing...

Trial ends in Request Full Access Tell Your Colleague About Jove

Medicine

A Novel Technique of Rescuing Capsulorhexis Radial Tear-out using a Cystotome

Published: January 16, 2011 doi: 10.3791/2317
* These authors contributed equally

Summary

Capsulorhexis is an important step in phacoemulsification surgery. A surgeon creates a continous curvilinear tear on the anterior lens capsule by controlling the tearing vector forces. A peripherally extended tear is a serious complication. This video demonstrates a novel technique of rescuing capsular radial tear out using a cystotome.

Abstract

Part 1 : Purpose: To demonstrate a capsulorhexis radial tear out rescue technique using a cystotome on a virtual reality cataract surgery simulator and in a human eye. Part 2 : Method: Steps: When a capsulorhexis begins to veer radially towards the periphery beyond the pupillary margin the following steps should be applied without delay. 2.1) Stop further capsulorhexis manoeuvre and reassess the situation. 2.2) Fill the anterior chamber with ophthalmic viscosurgical device (OVD). We recommend mounting the cystotome to a syringe containing OVD so that the anterior chamber can be reinflated rapidly. 2.3) The capsulorhexis flap is then left unfolded on the lens surface. 2.4) The cystotome tip is tilted horizontally to avoid cutting or puncturing the flap and is engaged on the flap near the leading edge of the tear but not too close to the point of tear. 2.5) Gently push or pull the leading edge of tear opposite to the direction of tear. 2.6) The leading tearing edge will start to do a 'U-Turn'. Maintain the tension on the flap until the tearing edge returns to the desired trajectory. Part 3 : Results: Using our technique, a surgeon can respond instantly to radial tear out without having to change surgical instruments. Changing surgical instruments at this critical stage runs a risk of further radial tear due to sudden shallowing of anterior chamber as a result of forward pressure from the vitreous. Our technique also has the advantage of reducing corneal wound distortion and subsequent anterior chamber collapse. Part 4 : Discussion The EYESI Surgical Simulator is a realistic training platform for surgeons to practice complex capsulorhexis tear-out techniques. Capsulorhexis is the most important and complex part of phacoemulsification and endocapsular intraocular lens implantation procedure. A successful cataract surgery depends on achieving a good capsulorhexis. During capsulorhexis, surgeons may face a challenging situation like a capsulorhexis radial tear-out. A surgeon must learn to tackle the problem promptly without making the situation worse. Some other methods of rescuing the situation have been described using a capsulorhexis forceps. However, we believe our method is quicker, more effective and easier to manipulate as demonstrated on the EYESi surgical simulator and on a human eye. Acknowledgments: List acknowledgements and funding sources. We would like to thank Dr. Wael El Gendy, for video clip. Disclosures: describe potential conflicting interests or state We have nothing to disclose. References: 1. Brian C. Little, Jennifer H. Smith, Mark Packer. J Cataract Refract Surg 2006; 32:1420 1422, Issue-9. 2. Neuhann T. Theorie und Operationstechnik der Kapsulorhexis. Klin Monatsbl Augenheilkd. 1987; 1990: 542-545. 3. Gimbel HV, Neuhann T. Development, advantages and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg. 1990; 16: 31-37. 4. Gimbel HV, Neuhann T. Continuous curvilinear capsulorhexis. (letter) J Cataract Refract Sur. 1991; 17: 110-111.

Protocol

1. Purpose

To demonstrate a capsulorhexis radial tear out rescue technique using a cystotome on a virtual reality cataract surgery simulator and in a human eye.

2. Method

When a capsulorhexis begins to veer radially towards the periphery beyond the pupillary margin the following steps should be applied without delay.

  1. Stop further capsulorhexis manoeuvre and reassess the situation.
  2. Fill the anterior chamber with ophthalmic viscosurgical device (OVD). We recommend mounting the cystotome to a syringe containing OVD so that the anterior chamber can be reinflated rapidly.
  3. The capsulorhexis flap is then left unfolded on the lens surface.
  4. The cystotome tip is tilted horizontally to avoid cutting or puncturing the flap and is engaged on the flap near the leading edge of the tear but not too close to the point of tear.
  5. Gently push or pull the leading edge of tear opposite to the direction of tear.
  6. The leading tearing edge will start to do a 'U-Turn'. Maintain the tension on the flap until the tearing edge returns to the desired trajectory.

3. Results

Using our technique, a surgeon can respond instantly to radial tear out without having to change surgical instruments. Changing surgical instruments at this critical stage runs a risk of further radial tear due to sudden shallowing of anterior chamber as a result of forward pressure from the vitreous. Our technique also has the advantage of reducing corneal wound distortion and subsequent anterior chamber collapse.

Subscription Required. Please recommend JoVE to your librarian.

Discussion

The EYESI Surgical Simulator is a realistic training platform for surgeons to practice complex capsulorhexis tear-out techniques. Capsulorhexis is the most important and complex part of phacoemulsification and endocapsular intraocular lens implantation procedure. A successful cataract surgery depends on achieving a good capsulorhexis. During capsulorhexis, surgeons may face a challenging situation like a capsulorhexis radial tear-out. A surgeon must learn to tackle the problem promptly without making the situation worse. Some other methods of rescuing the situation have been described using a capsulorhexis forceps. However, we believe our method is quicker, more effective and easier to manipulate as demonstrated on the EYESi surgical simulator and on a human eye.

Subscription Required. Please recommend JoVE to your librarian.

Disclosures

No conflicts of interest declared.

Acknowledgments

We would like to thank Dr. Wael El Gendy, for video clip, Dr Clemens Wagner from VR magic for his moral support. Authors personal funding.

Materials

Name Company Catalog Number Comments
0.06% Trypan Blue DORC International NEC0011(Clinic cat.)
EyeSi Cataract surgery simulator VRMagic

DOWNLOAD MATERIALS LIST

References

  1. Little, B. C., Smith, J. H., Packer, M. J Cataract Refract Surg. 32 (9), 1420-1422 (2006).
  2. Neuhann, T. Theorie und Operationstechnik der Kapsulorhexis. Klin Monatsbl Augenheilkd. 190, 542-545 (1987).
  3. Gimbel, H. V., Neuhann, T. Development, advantages and methods of the continuous circular capsulorhexis technique. J Cataract Refract Surg. 16, 31-37 (1990).
  4. Gimbel, H. V., Neuhann, T. Continuous curvilinear capsulorhexis. (letter). J Cataract Refract Sur. 17, 110-111 (1991).
  5. Gimbel, H. V. Evolving techniques of cataract surgery: continuous curvilinear capsulorhexis, down-slope sculpting, and nucleofractis. Semin Ophthalmol. 7, 193-207 (1992).

Tags

Capsulorhexis Radial Tear-out Rescue Technique Cystotome Virtual Reality Cataract Surgery Simulator Human Eye Capsulorhexis Manoeuvre Ophthalmic Viscosurgical Device (OVD) Leading Edge Of Tear U-Turn Surgeon Surgical Instruments Anterior Chamber
A Novel Technique of Rescuing Capsulorhexis Radial Tear-out using a Cystotome
Play Video
PDF DOI DOWNLOAD MATERIALS LIST

Cite this Article

Karim, S. M. R., Ong, C. T., Miah,More

Karim, S. M. R., Ong, C. T., Miah, M. R., Sleep, T., Hanifudin, A. A Novel Technique of Rescuing Capsulorhexis Radial Tear-out using a Cystotome. J. Vis. Exp. (47), e2317, doi:10.3791/2317 (2011).

Less
Copy Citation Download Citation Reprints and Permissions
View Video

Get cutting-edge science videos from JoVE sent straight to your inbox every month.

Waiting X
Simple Hit Counter