The Journal of Visualized Experiments (JoVE) is a peer reviewed, PubMed-indexed video journal. Our mission is to increase the productivity of scientific research.
1Department of Evolutionary Biology of Invertebrates, University of Tubingen, 2European Synchrotron Radiation Facility
This article is a part of JoVE General. If you think this article would be useful for your research, please recommend JoVE to your institution's librarian.
Recommend JoVE to Your LibrarianCurrent Access Through Your IP Address
Current Access Through Your Registered Email Address
Heethoff, M., Helfen, L., Cloetens, P. Non-invasive 3D-Visualization with Sub-micron Resolution Using Synchrotron-X-ray-tomography. J. Vis. Exp. (15), e737, doi:10.3791/737 (2008).
Little is known about the internal organization of many micro-arthropods with body sizes below 1 mm. The reasons for that are the small size and the hard cuticle which makes it difficult to use protocols of classical histology. In addition, histological sectioning destroys the sample and can therefore not be used for unique material. Hence, a non-destructive method is desirable which allows to view inside small samples without the need of sectioning.
We used synchrotron X-ray tomography at the European Synchrotron Radiation Facility (ESRF) in Grenoble (France) to non-invasively produce 3D tomographic datasets with a pixel-resolution of 0.7µm. Using volume rendering software, this allows us to reconstruct the internal organization in its natural state without the artefacts produced by histological sectioning. These date can be used for quantitative morphology, landmarks, or for the visualization of animated movies to understand the structure of hidden body parts and to follow complete organ systems or tissues through the samples.
Animals used in this study
Specimens of the parthenogenetic oribatid mite Archegozetes longisetosus (Acari, Oribatida) were taken from our laboratory culture. The culture grows on a plaster of Paris/charcoal mix (9:1) in plastic jars, in constant dark at 20-23°C with approximately 90% of air humidity.
Sample preparation
Synchrotron X-ray tomography
X-ray tomography was performed at beamline ID19 (ESRF, Grenoble, France, experiment SC-2127).
Using a certain distance between sample and detector enables a differential imaging of materials with low X-ray attenuation coefficients (Cloetens, et al. 1996), which would produce insufficient contrast in absorbtion imaging (where the sample is located directly in front of the detector). Most biological matters are phase objects, composed of materials with low absorbtion and/or only small differences in atomic number (Betz, et al. 2007). However, phase enhanced tomography requires a high spatial coherence of a homogeneous X-ray beam. Therefore, synchrotron radiation is better suited than desktop-scanners for these kind of measurements.
Data analysis
Subscription Required. Please recommend JoVE to your librarian.
In this presentation, we focused on the 3D-visualization of the internal anatomy of a chelicerate micro-arthropod. The synchrotron X-ray measurements allow a pixel-resolution of down to 0.3µm, depending on the size of the sample. Here, we have shown data with 0.7µm pixel-resolution. Generally, synchrotron X-ray tomography can be useful for analysing small biological materials (or tissues) with low X-ray attenuation. The pixel resolution almost reaches that of conventional light microscopy. The technique can be applied to any kind of material for which the internal organisation is of interest and which must not be destroyed by sectioning. Histological sectioning, however, has the advantage that tissues can be stained differentially, which is not possible with X-ray tomography. But here, different gray-values correspond to tissues with different X-ray attenuation, and the grey-value distribution can be expanded using quantitative phase tomography (holotomography; Cloetens et al.,1999; Heethoff & Cloetens, 2008) . The technique of synchrotron X-ray tomography is extraordinary valuable due to the following reasons:
We suggest considering this technique whenever the internal structures in natural state of small samples or of samples which must not be destroyed (e.g., fossils in amber or type-specimens) are to be analysed. Of course, this technique is not restricted to biological materials, but here it is of the biggest advantage due to the possibility of analysing materials with X-rays which have low X-ray attenuation.
Subscription Required. Please recommend JoVE to your librarian.
The authors have nothing to disclose.
We thank Paavo Bergmann, Michael Laumann, and Sebastian Schmelzle for their help at the ESRF. This work was supported by the European Synchrotron Radiation Facility project SC-2127 through the allocation of beam time.
1. Betz, O., U. Wegst, D. Weide, M. Heethoff, L. Helfen, W. -K. Lee & Cloetens, P. Imaging applications of synchrotron X-ray phase-contrast microtomography in biological morphology and biomaterial science. I. General aspects of the technique and its advantages in the analysis of millimetre-sized arthropod structure. J. Microscopy 22, 51-71 (2007).
2. Cloetens, P., R. Barrett, J. Baruchel, J. P. Guigay & M. Schlenker. Phase objects in synchrotron radiation hard X-ray imaging. J. Phys. D: Appl. Phys. 29, 133-146 (1996).
3. Cloetens, P., Pateyron-Salome, M., Buffiere, J.Y., Peix, G., Baruchel, J., Peyrin, V., Schlenker, M. Observation in microstructure and damage in materials by phase sensitive radiography and tomography. J. Apll. Phys. 81, 5878-5886 (1997).
4. Clotens, P., Ludwig, W., Baruchel, J., van Dyck, D., van Landyut, J., Guigay, J.P., Schlenker, M. Holotomography: quantitative phase tomography with micrometer resolution using hard synchrotron radiation X-rays. Appl. Phys. Lett. 75, 2912-2914 (1999).
5. Heethoff, M., Cloetens, P. A Comparison of aynchrotron X-ray phase contrast tomography and holotomography for non-invasive investigations of the internal anatomy of mites. Soil Organisms, in press (2008).
It is fantastic! Congratulations. pi
1
ReplyPosted by: prazsiAugust 6, 2008, 2:17 PM