Waiting
로그인 처리 중...

Trial ends in Request Full Access Tell Your Colleague About Jove
Experiment
JoVE Encyclopedia of Experiments
Encyclopedia of Experiments: Immunology

JoVE 비디오를 활용하시려면 도서관을 통한 기관 구독이 필요합니다. 전체 비디오를 보시려면 로그인하거나 무료 트라이얼을 시작하세요.

Using a Sandwich ELISA to Determine the Immunogenic Glycoprotein Content in a Vaccine

 

Using a Sandwich ELISA to Determine the Immunogenic Glycoprotein Content in a Vaccine

Article

Transcript

To wash the blade, add 300 microliters of the washing buffer to each well. Then, aspirate carefully and transfer the well content into a recipient containing a solution of 2.6% sodium hypochlorite. Repeat this washing process five more times to extensively wash the sensitized plate.

After this, invert the microplate, and let it dry on a piece of absorbent paper at room temperature for one minute. Reconstitute the reference vaccine in one milliliter of distilled water such that the final concentration of rabies virus glycoprotein is 10 micrograms per milliliter. Prepare a 10-fold dilution of the reconstituted reference vaccine in the diluent to reach a rabies virus glycoprotein concentration of one microgram per milliliter.

Next, perform six serial twofold dilutions of this reference vaccine in the diluent as outlined in table one of the text protocol. Distribute 200 microliters of the diluent in duplicate wells to serve as a blank control, and 200 microliters per well for each reference vaccine dilution in duplicate.

Then, prepare a 10-fold dilution of the tested vaccine in the diluent, and prepare seven twofold serial dilutions of the tested vaccine in diluent as outlined in table two of the text protocol. Distribute 200 microliters of each tested vaccine dilution in duplicate to each well of the microplate. Cover the microplate with adhesive film, and incubate at 37 degrees Celsius for one hour.

After this, remove the film, aspirate carefully, and transfer the contents of each well into a recipient containing a 2.7% sodium hypochlorite solution. To wash the plate, add 300 microliters of washing buffer to each well. Aspirate carefully, and transfer the contents of each well into a recipient containing a 2.6% sodium hypochlorite solution.

Repeat the washing process five more times to remove the unbound antigen. and conserve the G-protein trimers bound to the coated antibody. Invert the washed microplate, and let it dry on a piece of absorbent paper at room temperature for one minute. Then, distribute 200 microliters of the recommended dilution of peroxidase-labeled D1 monoclonal antibody in diluent to each well.

Cover the microplate with adhesive film, and incubate at 37 degrees Celsius for one hour. Next, remove the film, aspirate carefully, and transfer the contents of each well into a recipient containing a 2.6% sodium hypochlorite solution. To wash the microplate, add 300 microliters of washing buffer to each well.

Aspirate carefully, and transfer the contents of each well into a recipient containing a 2.6% sodium hypochlorite solution. Repeat this washing process five more times to remove the unbound peroxidase-labeled antibody. Invert the wash microplate, and let it dry on a piece of absorbent paper at room temperature for one minute.

Next, distribute 200 microliters of substrate chromogen solution into each well. Seal the microplate with film, and incubate at room temperature in the dark for 30 minutes. Then, add 50 microliters of stopping solution into each well to stop the reaction.

Carefully, wipe the bottom of the microblade, and place it in a spectrophotometer. Determine the optical density at 492 nanometers for all of the wells used. Collect this data in a spreadsheet file for analysis. After this, create plots for both the reference vaccine curve and the optical density values as outlined in the text protocol.

Read Article

Get cutting-edge science videos from JoVE sent straight to your inbox every month.

Waiting X
Simple Hit Counter