Summary

Tillverkning av finkalibrig stent-transplantat Använda Electro och ballongutvidgning Bare metallstentar

Published: October 26, 2016
doi:

Summary

In the protocol, we present a method to manufacture a small caliber stent-graft by sandwiching a balloon expandable stent between two electrospun nanofibrous polyurethane layers.

Abstract

Stent-grafts are widely used for the treatment of various conditions such as aortic lesions, aneurysms, emboli due to coronary intervention procedures and perforations in vasculature. Such stent-grafts are manufactured by covering a stent with a polymer membrane. An ideal stent-graft should have a biocompatible stent covered by a porous, thromboresistant, and biocompatible polymer membrane which mimics the extracellular matrix thereby promoting injury site healing. The goal of this protocol is to manufacture a small caliber stent-graft by encapsulating a balloon expandable stent within two layers of electrospun polyurethane nanofibers. Electrospinning of polyurethane has been shown to assist in healing by mimicking native extracellular matrix, thereby promoting endothelialization. Electrospinning polyurethane nanofibers on a slowly rotating mandrel enabled us to precisely control the thickness of the nanofibrous membrane, which is essential to achieve a small caliber balloon expandable stent-graft. Mechanical validation by crimping and expansion of the stent-graft has shown that the nanofibrous polyurethane membrane is sufficiently flexible to crimp and expand while staying patent without showing any signs of tearing or delamination. Furthermore, stent-grafts fabricated using the methods described here are capable of being implanted using a coronary intervention procedure using standard size guide catheters.

Introduction

Koronar intervention förfaranden orsaka betydande kärlväggen skada på grund av störningar av plack och kärlväggen. Detta resulterar i restenos, perifera embolism i ventransplantat och diskontinuitet av koronar lumen 1-4. För att undvika dessa komplikationer, kommer en lovande strategi vara att täcka kärlytan i angioplastikstället, som potentiellt kommer att hämma restenos, minska riskerna från avbrott av kärllumen, och förhindra perifer emboli. Tidigare studier har jämfört nakna metallstentar att stent-transplantat med positiva resultat för stent-implantat 5. Forskare har använt flera material för att tillverka membran för att täcka stentar. Detta inkluderar syntetiska material såsom polyetylen tetraphthalate (PET), polytetrafluoretylen (PTFE), polyuretan (PU) och kisel eller autolog kärlet vävnad att tillverka täckta stentar 6-9. En idealisk ympmaterial används för att täcka stenten bör tromboresistent, icke-biodegradable, och bör integrera med naturlig vävnad utan överdriven proliferation och inflammation 10. Transplantatmaterialet som används för att täcka stenten bör även främja läkning av stent-implantatet.

Stent-implantat används i stor utsträckning för behandling av aorta koarktation, pseudo-aneurysm i karotidartären, arteriovenösa fistlar, degenererade ventransplantat, och stor för att jätte cerebral aneurysm. Men utvecklingen av finkalibriga stent-implantat begränsas av förmågan att bibehålla låg profil och flexibilitet, vilket underlättar utplaceringen av stent-implantat 11-14. PU är en elastomer polymer med god mekanisk hållfasthet, vilket är en önskvärd egenskap för att uppnå en låg profil och god flexibilitet 15,16. Förutom att ha god leverans bör stent-transplantat också främja en snabb läkning och endotelialisering. PU täckt stent-transplantat har visat bättre biokompatibilitet och förbättrad endotelisering 17. forskare hartidigare försökt endothelialize PU täckt stent-implantat genom ympning dem med endotelceller 17. Electro PU att skapa nanofibrer matris har visat sig vara en värdefull teknik för produktion av blodkärl 18,19. Förekomsten av nanofibrer som efterliknar strukturen för nativa extracellulära matrisen är också känd för att främja endotelcellproliferation 20,21. Elektrospinning möjliggör också kontroll över tjockleken på materialet 22. Liten kaliber vaskulära transplantat gjorda av PU har studerats för att främja läkning genom att använda modifieringar såsom ytbeläggningar, antikoagulantia, och cellproliferationshämmande medel. Alla dessa ändringar är utformade för att förmedla värd acceptans och främja transplantat healing 23.

Vår grupp har utvecklat en ballong expander bare metal stent som kan användas i djurmodeller 24-26. Kombinationen av en electrospun polyuretan mesh och en bolloon expanderbar stent har gjort det möjligt för oss att generera finkalibrig ballongutvidgning stent-transplantat. De flesta av de för närvarande tillgängliga stent-implantat införs genom lårbensartären under en ingreppet, men endast ett fåtal kommersiella täckta stentar kan införas en fransk storlek större än vad som krävs för en un-uppblåsta ballongen 27. I denna studie har vi utvecklat en finkalibrig vaskulär stent-implantat genom inkapsling en ballong expanderbar stent mellan två skikt av electrospun PU som kan levereras till en kransartär med användning av en standard 8-9 French styrkateter i en perkutan interventionsprocedur.

Protocol

1. Electro av polyuretan på dragdornet Collector Förbereda dorn för elektrospinning Smälter ca 8 ml av biokompatibla, av livsmedelskvalitet, vattenlösligt bärarmaterial i en graderad cylinder (cirka 9 mm diameter och 110 mm djup) vid 155 ° C med hjälp av en ugn. Doppa en 3 mm diameter och 100 mm lång rostfri spindel för att erhålla en beläggning av bärarmaterial på ytan av dornen. Före doppning, placera spindlarna i ugnen vid 155 ° C i ungefär 15 minuter f?…

Representative Results

Vår electrospinner setup (Figur 1) har resulterat i hög kvalitet polyuretan Nanofiber (Figur 2). En stent-implantatet tillverkas genom elektrospinning ett inre skikt av polyuretan på en dorn, glider en ren metall stent över detta skikt, och elektrospinning ett andra yttre skikt av polyuretan (Figur 3). Polyuretannanofibrer är electrospun med en hastighet av 50 ^ m / h, vilket resulterar i ett inre skikt av 100 | im och ett yttre skikt av 150 | im på stent-im…

Discussion

We have developed a fabrication technique for a small caliber stent-graft which can be deployed using a standard percutaneous coronary intervention (PCI) procedure. Stent-grafts currently available are limited in their ability to maintain a low profile and flexibility for deployment. Bare metal stents developed by our group in our previous studies have proven to assist in rapid healing of the stented artery24,26. Various polymers have been electrospun by other groups and polyurethane has been proven biostable …

Disclosures

The authors have nothing to disclose.

Acknowledgements

We would like to thank the Division of Engineering, Mayo Clinic for their technical support. This study was financially supported by European Regional Development Fund – FNUSA-ICRC (No. CZ.1.05/1.100/02.0123), National Institutes of Health (T32 HL007111), American Heart Association Scientist Development Grant (AHA #06-35185N), and The Grainger Innovation Fund – Grainger Foundation.

Materials

Glass syringe Air Tite 7.140-33 Syringe for spinneret
Graduated cylinder 5 mL Fisher Scientific 08-552-4G 5 mL pyrex graduated cylinder about 9mm diameter and 11 cm long
High voltage generator Bertan Accociates, Inc. 205A-30P Used to apply voltage difference across spinneret and collector
Laboratory mixer with rpm control Scilogex SCI-84010201 Available from various laboratory equipment suppliers
Polyurethane DSM BioSpan SPU Biospan Segmented Polyurethane
Rubber sheet McMaster Carr 1370N11 Used to insulate syringe during electrospinning
Stainless steel mandrel N/A N/A Manufactured 
Stainless steel needle Hamilton 91018 Used as spinneret in electrospinning
Support material EnvisionTec B04-HT-DEMOMAT Biocompatible water soluble material
Syringe Pump Harvard Apparatus 55-3333

References

  1. Elsner, M., et al. Coronary stent grafts covered by a polytetrafluoroethylene membrane. Am. J. Cardiol. 84 (3), 335-338 (1999).
  2. Störger, H., Haase, J. Polytetrafluoroethylene-Covered Stents: Indications, Advantages, and Limitations. J. Interv. Cardiol. 12 (6), 451-456 (1999).
  3. Moreno, P. R., et al. Macrophage infiltration predicts restenosis after coronary intervention in patients with unstable angina. Circulation. 94 (12), 3098-3102 (1996).
  4. Briguori, C., Sarais, C., Colombo, A. The polytetrafluoroethylene-covered stent: a device with multiple potential advantages. Int. J. Cardiovasc. Interv. 4 (3), 145-149 (2001).
  5. Qureshi, M. A., Martin, Z., Greenberg, R. K. Endovascular management of patients with Takayasu arteritis: stents versus stent grafts. Semin. Vasc. Surg. 24 (1), 44-52 (2011).
  6. Ahmadi, R., Schillinger, M., Maca, T., Minar, E. Femoropopliteal arteries: immediate and long-term results with a Dacron-covered stent-graft. Radiology. 223 (2), 345-350 (2002).
  7. Geremia, G., et al. Experimental arteriovenous fistulas: treatment with silicone-covered metallic stents. AJNR. Am. J. Neuroradiol. 18 (2), 271-277 (1997).
  8. Saatci, I., et al. Treatment of internal carotid artery aneurysms with a covered stent: experience in 24 patients with mid-term follow-up results. AJNR. Am. J. Neuroradiol. 25 (10), 1742-1749 (2004).
  9. Stefanadis, C., et al. Stents Wrapped in Autologous Vein: An Experimental Study1. J. Am. Coll. Cardiol. 28 (4), 1039-1046 (1996).
  10. Palmaz, J. C. Review of polymeric graft materials for endovascular applications. J. Vasc. Interv. Radiol. 9, 7-13 (1998).
  11. Bruckheimer, E., Dagan, T., Amir, G., Birk, E. Covered Cheatham-Platinum stents for serial dilation of severe native aortic coarctation. Catheter Cardiovasc. Interv. 74 (1), 117-123 (2009).
  12. Tzifa, A., et al. Covered Cheatham-platinum stents for aortic coarctation: early and intermediate-term results. J. Am. Coll. Cardiol. 47 (7), 1457-1463 (2006).
  13. Kuraishi, K., et al. Development of nanofiber-covered stents using electrospinning: in vitro and acute phase in vivo experiments. J. Biomed. Mater. Res. Part B Appl. Biomater. 88 (1), 230-239 (2009).
  14. Pant, S., Bressloff, N. W., Limbert, G. Geometry parameterization and multidisciplinary constrained optimization of coronary stents. Biomech. Model Mechanobiol. 11 (1-2), 61-82 (2012).
  15. Muller-Hulsbeck, S., et al. Experience on endothelial cell adhesion on vascular stents and stent-grafts: first in vitro results. Invest. Radiol. 37 (6), 314-320 (2002).
  16. Sarkar, S., Salacinski, H. J., Hamilton, G., Seifalian, A. M. The mechanical properties of infrainguinal vascular bypass grafts: their role in influencing patency. Eur. J. Vasc. Endovasc. Surg. 31 (6), 627-636 (2006).
  17. Shirota, T., Yasui, H., Shimokawa, H., Matsuda, T. Fabrication of endothelial progenitor cell (EPC)-seeded intravascular stent devices and in vitro endothelialization on hybrid vascular tissue. Biomaterials. 24 (13), 2295-2302 (2003).
  18. Grasl, C., et al. Electrospun polyurethane vascular grafts: in vitro mechanical behavior and endothelial adhesion molecule expression. J. Biomed. Mater. Res. A. 93 (2), 716-723 (2010).
  19. Kidoaki, S., Kwon, I. K., Matsuda, T. Structural features and mechanical properties of in situ-bonded meshes of segmented polyurethane electrospun from mixed solvents. J. Biomed. Mater. Res. Part B Appl. Biomater. 76 (1), 219-229 (2006).
  20. Stegemann, J. P., Kaszuba, S. N., Rowe, S. L. Review: advances in vascular tissue engineering using protein-based biomaterials. Tissue Eng. 13 (11), 2601-2613 (2007).
  21. Sankaran, K. K., Subramanian, A., Krishnan, U. M., Sethuraman, S. Nanoarchitecture of scaffolds and endothelial cells in engineering small diameter vascular grafts. Biotechnol. J. 10 (1), 96-108 (2015).
  22. Gibson, P., Schreuder-Gibson, H., Rivin, D. Transport properties of porous membranes based on electrospun nanofibers. Colloid Surf., A. 187, 469-481 (2001).
  23. Zdrahala, R. J. Small caliber vascular grafts. Part II: Polyurethanes revisited. J. Biomater. Appl. 11 (1), 37-61 (1996).
  24. Uthamaraj, S., et al. Design and validation of a novel ferromagnetic bare metal stent capable of capturing and retaining endothelial cells. Ann. Biomed. Eng. 42 (12), 2416-2424 (2014).
  25. Tefft, B. J., et al. Cell Labeling and Targeting with Superparamagnetic Iron Oxide Nanoparticles. J. Vis. Exp. (105), e53099 (2015).
  26. Uthamaraj, S., et al. Ferromagnetic Bare Metal Stent for Endothelial Cell Capture and Retention. J. Vis. Exp. (103), e53100 (2015).
  27. de Giovanni, J. V. Covered stents in the treatment of aortic coarctation. J. Interv. Cardiol. 14 (2), 187-190 (2001).
  28. Hans, F. J., et al. Treatment of wide-necked aneurysms with balloon-expandable polyurethane-covered stentgrafts: experience in an animal model. Acta. Neurochir. (Wien). 147 (8), 871-876 (2005).
  29. Hasan, A., et al. Electrospun scaffolds for tissue engineering of vascular grafts. Acta. Biomater. 10 (1), 11-25 (2014).

Play Video

Cite This Article
Uthamaraj, S., Tefft, B. J., Jana, S., Hlinomaz, O., Kalra, M., Lerman, A., Dragomir-Daescu, D., Sandhu, G. S. Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents. J. Vis. Exp. (116), e54731, doi:10.3791/54731 (2016).

View Video