宾夕法尼亚州立大学, 宾夕法尼亚大学帕克分校, Rioux 和刘志峰先生

去污对实验室生物安全至关重要, 因为实验室微生物污染的积聚会导致疾病的传播。除污程度可分为消毒或杀菌两种。消毒的目的是消除所有致病微生物, 除了实验室表面或设备上的细菌孢子。另一方面, 绝育的目的是消除所有微生物的生命。有不同的方法, 包括化学品, 热和辐射, 并再次取决于污染程度, 以及污染物的微生物浓度, 存在的有机物, 和类型的设备或表面被清理。每种方法都有其优点和需要采取的警示措施, 以避免危害.

Principles

Procedure

1. 化学药品 液体化学品 液体消毒剂广泛用于实验室净化。液体消毒剂的功效取决于多种因素, 如消毒剂的化学性质、消毒剂的浓度和数量、接触时间和温度等。请记住, 没有液体消毒剂适用于所有情况。确保根据检测到的微生物选择合适的消毒剂, 采用以下标准: a. 污染微生物类型: 不同的微生物对消毒剂有不同的耐药性。例如, 细菌孢子比亲油性病毒的化学抗性要强得多. …

Applications and Summary

To avoid infection transmission and maintain biosafety in the lab, periodic decontamination in the lab is important. Three methods are available including chemical, heat, and radiation. Each method has its own strength and suitable applications. Awareness of the type of microorganism in the laboratory environment is useful for selection of a suitable decontamination method. Appropriate safety protocols should be in place during the decontamination procedure.

References

  1. Center for Disease Control. A Guide to Selection and Use of Disinfectants. (2003)
  2. Biosafety: Decontamination Methods for Laboratory Use, 2016, Blink, University of California, San Diego. at http://blink.ucsd.edu/safety/research-lab/biosafety/decontamination/#Vapors-and-gases
  3. Disinfectants and Sterilization Methods, 2008, Environmental Health & Safety, University of Colorado Boulder. at https://ehs.colorado.edu/resources/disinfectants-and-sterilization-methods/

Transcript

Decontamination of laboratory space is essential to prevent accumulation and spreading of microbes that can lead to the transmission of diseases.

Decontamination falls into two categories: disinfection and sterilization. Disinfection involves eliminating nearly all pathogenic microorganisms, with the exception of microbial spores on laboratory surfaces and equipment. Sterilization, on the other hand, is a more lethal process, eliminating all microbial life.

Decontamination is carried out using a variety of methods, such as chemicals, heat, or radiation. The choice of method depends on the degree of contamination as well as the type and concentration of the contaminant.

This video will illustrate the types of decontamination and the procedures for disinfection and sterilization of machines, surfaces, and equipment.

Prior to establishing a decontamination procedure, the type, concentration, and location of the microorganism must be determined. Types of microorganisms include Gram-positive or -negative bacteria; viruses; fungi; bacterial spores; and algae. Once the type of microorganism is established, a suitable disinfectant should be chosen.

When selecting a decontamination method the effectiveness of a disinfectant has to be considered, which is dependent on factors such as its chemical composition; the amount, concentration, contact time; and temperature.

Now that we have discussed how to choose a method for decontamination, let’s explore the various types used for an actual procedure.

Liquid chemicals are categorized in three levels, as low-, intermediate-, and high-degree disinfectants. Regardless of which you choose, always wear appropriate personal protective equipment when working with hazardous materials.

Most non-critical microorganisms require only low-level disinfectants, which are low in toxicity, but cause irritation upon long exposure times. Common low-level disinfectants are quaternary ammonium compounds, such as benzalkonium chloride and ammonium chloride, and phenolic compounds, such as o-phenylphenol and chloroxylenol.

For the decontamination of more resistant microorganisms, alcohol-based chemicals are used in areas ranging from healthcare to laboratories.

Additionally, halogen-based compounds, such as hypochlorites and iodophors are often applied as antiseptics and disinfectants of medical equipment. However these agents have prolonged contact times and their effectiveness is decreased in the presence of organic matter.

High level disinfectants, which can be classified as oxidizers, acids, and aldehydes are used if decontamination of all microorganisms is required.

Oxidizers such as hydrogen peroxide are fast-acting and often used as antiseptics for wound cleaning and to disinfect environmental surfaces like benchtops. But be careful, as exposure to high concentrations of hydrogen peroxide can be harmful to tissue and airways.

Peracetic acid is generally used to disinfect automated machines and to sterilize medical, surgical, and dental instruments. The advantage of peracetic acid and other oxidizers is a short contact time; however, the use of material to be disinfected can be limited, due to corrosion of metals in acids, for example.

Aldehydes on the other hand, such as formaldehyde or gluteraldehyde, are non-corrosive, but are still hazardous. These chemicals are used to sterilize various types of equipment, but suffer from prolonged contact time.

In addition to liquid chemicals, gaseous chemicals may also be used for decontamination purposes. Gases such as chlorine dioxide and ethylene oxide, as well as vaporized hydrogen peroxide and peracetic acid are frequently used to rid closed equipment, such as biosafety cabinets, of bacteria, viruses, and spores.

In addition to chemicals, heat is a common physical agent for the decontamination of pathogens.

There are two forms of heat. “Dry” heat is used under conditions of 160 to 170 degrees Celsius for 2 to 4 hours to disinfect glassware, but it is not suitable for heat-labile materials. On the other hand, “Wet” heat, also known as autoclaving, is used by heating samples and equipment to only 120 degrees Celsius for 30 to 60 minutes under high pressure.

Besides heat, ultraviolet radiation in the wavelength range of 250 to 270 nanometers is often used for decontamination. This method is effective against bacteria and viruses, but not against spores, and is used to decontaminate air, water, and surfaces such as in biological safety cabinets. Furthermore UV light in this range can cause burns of skin and eyes, thus proper PPE should be worn.

You’ve just watched JoVE’s introduction to Decontamination for Laboratory Safety. You should now understand the various types of microbial contaminants, how to choose a suitable method, and the types of disinfection and sterilization available. Thanks for watching!