Measuring SMC Contraction In Vitro: A Non-Invasive Method to Evaluate Smooth Muscle Cells Contraction using Electric Cell-Substrate Impedance Sensing

0 views • 3:45 min • July 8th, 2025

Loading...
$$\rightleftharpoonup{xx}$$ $$\longleftharp{xx}$$, $$\longrightharp{xx}$$,

The aorta wall predominantly has smooth muscle cells, or SMCs, containing contractile protein machinery that contract and relax to regulate aortic blood flow.

To measure the contractile response of aortic SMCs in vitro, obtain a multi-well plate containing an electrical cell-substrate impedance sensing, or ECIS, sensor array. Each array contains gold film electrodes at the well bottom, delineated with an insulating film. Coat the wells with gelatin.

Seed primary human SMC suspension into the wells. Transfer the ECIS-containing well plate to a plate holder connected to an amplifier and data acquisition system while ensuring electrode contact with the holder. Apply small constant alternating current between the electrodes to measure the potential across them.

During incubation, SMCs adhere and spread onto the gelatin coating. The cells behave as insulators, limiting the current flow between the electrodes. As more cells attach to the surface, the current flow decreases further. As a result, the impedance, or opposition to the current flow, and potential increase. Eventually, the cells proliferate on the electrodes and form a monolayer.

Treat the SMCs with a calcium ionophore to facilitate calcium ion transport across the cell membranes. The extracellular calcium ion influx activates the contractile apparatus, inducing contraction.

Stimulated SMCs contract and lose cell-cell contact on the electrodes. The resulting reduction in electrode surface coverage decreases the impedance, facilitating real-time quantification of SMC contraction.

Count the cells using an automated cell counter, and seed the SMCs in triplicate at a seeding density of 30,000 cells per well, in 200 microliters of SMC medium in the gelatin-coated ECIS plate. Place the plate with the SMCs into the ECIS 96-well holder in the cell culture incubator.

Double-click on the "ECIS Applied Biophysics software" to open the program, and press the "Setup" button. Check if all the electrodes have contact with the holder, in the left lower panel labeled "Well Configuration." If the electrodes are not properly connected, adjust the plate in the holder before starting the measurement.

Now, select the plate type in the same panel by clicking "Array Type." Next, prepare two pipettes set at 2-microliter and 150-microliter volume. Before starting the stimulation, press "Mark" in the software, and place a comment.

To stimulate the cells, remove the lid, and place it on a sterile surface inside the incubator. Then, induce SMC contraction by pipetting 2 microliters of the ionomycin working solution into each well as quickly as possible.

Once all the cells have been stimulated, mix the medium in the wells using the second pipette.

07:04

Isolation of Cardiac and Vascular Smooth Muscle Cells from Adult, Juvenile, Larval and Embryonic Zebrafish for Electrophysiological Studies

Related Videos

0 Views

07:56

Isolation of Intrapulmonary Artery and Smooth Muscle Cells to Investigate Vascular Responses

Related Videos

0 Views

11:47

Construction of a Human Aorta Smooth Muscle Cell Organ-On-A-Chip Model for Recapitulating Biomechanical Strain in the Aortic Wall

Related Videos

0 Views

12:30

Electric Cell-substrate Impedance Sensing for the Quantification of Endothelial Proliferation, Barrier Function, and Motility

Related Videos

0 Views

10:53

Utilization of Microscale Silicon Cantilevers to Assess Cellular Contractile Function In Vitro

Related Videos

0 Views

07:56

Contractility Measurements of Human Uterine Smooth Muscle to Aid Drug Development

Related Videos

0 Views

09:42

Isometric Contractility Measurement of the Mouse Mesenteric Artery Using Wire Myography

Related Videos

0 Views

08:19

In Vitro Assessment of Cardiac Function Using Skinned Cardiomyocytes

Related Videos

0 Views

08:28

Isolation of Primary Patient-specific Aortic Smooth Muscle Cells and Semiquantitative Real-time Contraction Measurements In Vitro

Related Videos

0 Views

14:33

Simplified, High-throughput Analysis of Single-cell Contractility using Micropatterned Elastomers

Related Videos

0 Views

Last updated: 18 July 2026