JoVE   
You do not have subscription access to articles in this section. Learn more about access.

  JoVE Biology

  
You do not have subscription access to articles in this section. Learn more about access.

  JoVE Neuroscience

  
You do not have subscription access to articles in this section. Learn more about access.

  JoVE Immunology and Infection

  
You do not have subscription access to articles in this section. Learn more about access.

  JoVE Clinical and Translational Medicine

  
You do not have subscription access to articles in this section. Learn more about access.

  JoVE Bioengineering

  
You do not have subscription access to articles in this section. Learn more about access.

  JoVE Applied Physics

  
You do not have subscription access to articles in this section. Learn more about access.

  JoVE Chemistry

  
You do not have subscription access to articles in this section. Learn more about access.

  JoVE Behavior

  
You do not have subscription access to articles in this section. Learn more about access.

  JoVE Environment

|   

JoVE Science Education

General Laboratory Techniques

You do not have subscription access to videos in this collection. Learn more about access.

Basic Methods in Cellular and Molecular Biology

You do not have subscription access to videos in this collection. Learn more about access.

Model Organisms I

You do not have subscription access to videos in this collection. Learn more about access.

Model Organisms II

You do not have subscription access to videos in this collection. Learn more about access.

Essentials of
Neuroscience

You do not have subscription access to videos in this collection. Learn more about access.

 JoVE Bioengineering

Studying Cell Rolling Trajectories on Asymmetric Receptor Patterns

1, 2, 1, 3, 2

1Department of Materials Science and Engineering, MIT - Massachusetts Institute of Technology, 2Department of Mechanical Engineering, MIT - Massachusetts Institute of Technology, 3HST Center for Biomedical Engineering and Harvard Stem Cell Institute, Brigham and Women's Hospital and Harvard Medical School

Article
    Downloads Comments Metrics

    You must be subscribed to JoVE to access this content.

    This article is a part of   JoVE Bioengineering. If you think this article would be useful for your research, please recommend JoVE to your institution's librarian.

    Recommend JoVE to Your Librarian

    Current Access Through Your IP Address

    You do not have access to any JoVE content through your current IP address.

    IP: 54.81.77.93, User IP: 54.81.77.93, User IP Hex: 911297885

    Current Access Through Your Registered Email Address

    You aren't signed into JoVE. If your institution subscribes to JoVE, please or create an account with your institutional email address to access this content.

     

    Summary

    We describe a protocol to observe and analyze cell rolling trajectories on asymmetric receptor-patterned substrates. The resulting data are useful for engineering of receptor-patterned substrates for label-free cell separation and analysis.

    Date Published: 2/13/2011, Issue 48; doi: 10.3791/2640

    Cite this Article

    Lee, C., Bose, S., Van Vliet, K. J., Karp, J. M., Karnik, R. Studying Cell Rolling Trajectories on Asymmetric Receptor Patterns. J. Vis. Exp. (48), e2640, doi:10.3791/2640 (2011).

    Abstract

    Lateral displacement of cells orthogonal to a flow stream by rolling on asymmetric receptor patterns presents an opportunity for development of new devices for label-free separation and analysis of cells1. Such devices may use lateral displacement for continuous-flow separation, or receptor patterns that modulate adhesion to distinguish between different cell phenotypes or levels of receptor expression. Understanding the nature of cell rolling trajectories on receptor-patterned substrates is necessary for engineering of the substrates and design of such devices.

    Here, we demonstrate a protocol for studying cell rolling trajectories on asymmetric receptor patterns that support cell rolling adhesion2. Well-defined, μm-scale patterns of P-selectin receptors were fabricated using microcontact printing on gold-coated slides that were incorporated in a flow chamber. HL60 cells expressing the PSGL-1 ligand 3were flowed across a field of patterned lines and visualized on an inverted bright field microscope. The cells rolled and tracked along the inclined edges of the patterns, resulting in lateral deflection1. Each cell typically rolled for a certain distance along the pattern edges (defined as the edge tracking length), detached from the edge, and reattached to a downstream pattern. Although this detachment makes it difficult to track the entire trajectory of a cell from entrance to exit in the flow chamber, particle-tracking software was used to analyze and yield the rolling trajectories of the cells during the time when they were moving on a single receptor-patterned line. The trajectories were then examined to obtain distributions of cell rolling velocities and the edge tracking lengths for each cell for different patterns.

    This protocol is useful for quantifying cell rolling trajectories on receptor patterns and relating these to engineering parameters such as pattern angle and shear stress. Such data will be useful for design of microfluidic devices for label-free cell separation and analysis.

    Protocol

    1. HL60 cell rolling

    1.1. Fabrication of Patterned Substrates.

    1. Using microcontact printing (μCP)4-7 to make alternating self-assembled monolayers (SAMs) of PEG molecules on the gold-coated glass slides: Fabricate microcontact printing polydimethylsiloxane (PDMS) stamps that defined the receptor patterns with inclination angle of α = 10° by an SU-8 molding process. Clean the gold surface with piranha solution (3:1 mixture of sulfuric acid to 30% hydrogen peroxide) for 20 minutes and then rinse the surface with copious DI water at 24.5 °C prior to use. Ink the PDMS stamp with 5mM PEG solution in ethanol. Dry the stamp in air for 20 minutes. Gently put the stamp on the gold surface for 40 sec and make sure there is a good contact between the gold surface and the stamp. No excess pressure is required. Rinse the surface with ethanol and dry it under a stream of N2.
    2. Incubate the substrate within P-selectin solution (15 μg/mL in DPBS) using a perfusion chamber (Electron Microscopy Sciences) for 3 hours at 24.5°C to pattern the remaining areas with P-selectin. Rinse the surface with copious DPBS.
    3. Backfill the surface with BSA (1 mg/mL in DPBS) for 1 h to block non-specific interactions.  Rinse the surface with copious DPBS.

    1.2. Cell Rolling Experiments in a Flow Chamber.

    1. Flow a suspension of HL60 cells (~105 cells/mL) over the patterned surfaces in a rectangular flow chamber (Glycotech, Inc; width w = 1.0 cm; length = 6 cm; height h = 0.0127 cm) at 24.5°C. Use a syringe pump (World Precision Instruments, SP230IW) to generate flow rate of 75 μL/min, with corresponding shear stress around 0.5 dyn/cm2 (~0.05 Pa). Calculate shear stress τ by using the plane Poiseuille flow equation τ = 6μQ/wh2, where μ is the kinematic viscosity (0.001002 Pa s), Q is volumetric flow rate, w is width of the flow chamber, and h is height of the flow chamber.
    2. Use an inverted microscope (Nikon TE2000-U) with a mounted camera (Andor iXon 885) to record HL60 cells rolling interactions with adhesive P-selectin substrates using a 4× objective, typically at a rate of 1 frame per second for durations of 300 s. Perform three independent experiments, for each shear stress magnitude and pattern inclination angle. Present data as mean and standard deviation of the average values obtained from each experiment.
    3. Data Analysis.
      Analyze the image sequences by a customized Matlab (Mathworks, Inc.) program that utilized a particle tracking freeware8 to generate tracks along the patterned line edges. Tracks extending till the end of a P-selectin band are selected and fitted with two straight line segments - one aligned with the flow, the other aligned with the pattern edge. These two segments are then used to calculate the edge tracking length, rolling velocity on the edge, and rolling velocity on the plain region.

    2. Representative Results:

    Figure 1
    Figure (A) shows one of microscope images converted from the video of HL60 rolling interactions with adhesive P-selectin substrates using a 4× objective. Bright and dark regions correspond to P-selectin receptor and PEG regions, respectively. Figure (B) shows the tracks obtained using a customized Matlab program. The edge inclination angle was 10° and the shear stress was 0.5 dyn/cm2. The edge tracking length, le, displacement, d, and the rolling velocities on the edge and inside the bands, Ve and Vp, respectively, are described in Figure (C-1). Figure (C-2) shows the distribution (the number of recorded cells) of edge tracking length. Insets show the average value of le and the rolling velocity on the edge (Ve) and inside the bands (Vp) at the inclination angle α =10° and the fluid shear stress magnitude around 0.5 dyn/cm2. Error bars represent one standard deviation, where n = 3 replicate experiments (3 replicate surfaces) for each condition.

    Subscription Required. Please recommend JoVE to your librarian.

    Discussion

    We have described a protocol to examine cell rolling trajectories on asymmetric receptor-patterned surfaces fabricated using microcontact printing2. The optical microscope images of patterned surface showing clear contrast between PEG and P-selectin areas can be used to confirm whether stamping is successful. Sharp, straight edges can be observed when the stamping is performed well. Hard pressing of the stamp may result in stamp deformation which limits the precision of patterns. Wavy edges may be obtained when the ink concentration is too high or the stamping time is too long. Bad contact between the stamp and the surface leads to non-uniform PEG patterns when the size of the stamp is too small (<0.5 cm2). Non-fresh ink solution may result in cells rolling on the PEG-patterned regions because of decreased ability to passivate P-selectin. The actual inclination angle can be calculated from images of the pattern and trajectories of free-flowing cells that are not interacting with the surfaces. The experiment described here yields information about individual cell rolling events along pattern edges; however, it is difficult to automatically track cells that detach on one pattern and re-attach on another pattern. Changing the pattern spacing, for example, may enable tracking of a single cell encountering multiple edges. This ability may enable higher resolution for distinguishing between cells with different rolling characteristics at the single cell level. As cell rolling behavior depends on the ligands on the cell, we hypothesize that such experiments may enable design of appropriate patterns to separate different cell phenotypes based on differences in their rolling behavior3, 9-12. This work can thus be useful for design of devices for cell separation and analysis based on interaction between cell ligands and the patterned asymmetric receptors.

    Subscription Required. Please recommend JoVE to your librarian.

    Disclosures

    No conflicts of interest declared.

    Acknowledgements

    This project was supported by the Deshpande Center for Technological Innovation at MIT (R.K. and J.M.K.) and the NSF CAREER award 0952493 to R.K. through the Chemical and Biological Separations program. We thank the Institute for Soldier Nanotechnologies (ISN) and the Microsystems Technology Laboratory (MTL) at MIT for use of their facilities.

    Materials

    Name Company Catalog Number Comments
    Human promyelocytic leukemia cells ATCC CCL-240 HL60 cells
    Gold-coated glass slides EMF TA134 Gold slides
    (1-Mercaptoundec-11-yl)tetra(ethylene glycol) Sigma-Aldrich 674508 PEG
    Recombinant human P-selectin R&D Systems ADP3-050 P-selectin
    Bovine serum albumin Rockland Immunochemicals BSA-50 BSA
    Dulbecco’s phosphate buffered saline Mediatech, Inc. 21-030 DPBS
    Sulfuric acid Sigma-Aldrich 339741
    Hydrogen peroxide Sigma-Aldrich 316989

    References

    1. Karnik, R., Hong, S., Zhang, H., Mei, Y., Anderson, D. G., Karp, J. M., Langer, R. Nanomechanical control of cell rolling in two dimensions through surface Patterning of receptors. Nano Lett. 8, (4), 1153-1158 (2008).
    2. Lee, C.-H., Bose, S., Van Vliet, K. J., Karp, J. M., Karnik, R. Examining Lateral Displacement of HL60 Cells Rolling on Asymmetric P-selectin Patterns. Langmuir, 27 (1), 240 249 (2011).
    3. Norman, K. E., Moore, K. L., McEver, R. P., Ley, K., Leukocyte rolling in-vivo is mediated by p-selectin glycoprotein ligand-1. Blood 86, (12), 4417-4421 (1995).
    4. Bernard, A., Delamarche, E., Schmid, H., Michel, B., Bosshard, H. R., Biebuyck, H. Printing patterns of proteins. Langmuir 14, (9), 2225-2229 (1998).
    5. James, C. D., Davis, R. C., Kam, L., Craighead, H. G., Isaacson, M., Turner, J. N., Shain, W. Patterned protein layers on solid substrates by thin stamp microcontact printing. Langmuir 14, (4), 741-744 (1998).
    6. Mrksich, M., Whitesides, G. M. Using self-assembled monolayers to understand the interactions of man-made surfaces with proteins and cells. Annual Review of Biophysics and Biomolecular Structure 25, 55-78 (1996).
    7. Tan, J. L., Tien, J., Chen, C. S. Microcontact printing of proteins on mixed self-assembled monolayers. Langmuir 18, (2), 519-523 (2002).
    8. http://physics.georgetown.edu/matlab/
    9. Lee, D., King, M. R. Microcontact Printing of P-Selectin Increases the Rate of Neutrophil Recruitment Under Shear Flow. Biotechnology Progress 24, (5), 1052-1059 (2008).
    10. Greenberg, A. W., Hammer, D. A. Cell separation mediated by differential rolling adhesion. Biotechnol. Bioeng. 73, (2), 111-124 (2001).
    11. Higuchi, A., Tsukamoto, Y. Cell separation of hepatocytes and fibroblasts through surface-modified polyurethane membranes. J. Biomed. Mater. Res. Part A 71A, (3), 470-479 (2004).
    12. Alexeev, A., Verberg, R., Balazs, A.C., Patterned surfaces segregate compliant microcapsules. Langmuir 23, (3), 983-987 (2007).