Waiting
Login processing...

Trial ends in Request Full Access Tell Your Colleague About Jove

Encyclopedia of Experiments

In Vivo Murine Liver Perfusion: A Method to Infuse the Rodent Liver with Solution via the Portal Vein

Overview

This video describes a procedure for mouse liver perfusion through the portal vein using collagenase solution prior to isolating liver cells.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.

1. Preparation

  1. Preparation of solutions and culture media
    1. Prepare all culture media and buffer according to the Table of Materials.
  2. Preparation of instruments
    1. Set up a water bath (>10 L) at 42 °C, a peristaltic pump with variable speed, and clamps for holding flasks. Prepare curved scissors and forceps (Figure 1).
    2. On or adjacent to the water bath, set up a baking sheet (about 38 x 26 cm) with a Styrofoam pad (50 mL conical rack), overlaid with an absorbent underpad cut into a 20 x 20 cm piece (Figure 1).
    3. Place a piece of masking tape (5–8 cm) nearby. Place a 20 cm polyester sewing thread nearby that is cut and ready to use. Obtain a plastic catheter with a retractable needle (7 mm x 19 mm, Figure 1).
  3. Preparation of glassware
    1. Using clamps, place and immobilize a 1 L flask in the water bath containing 200 mL of 1x PBS with a stopper that has two 1 mL pipettes going into the solution. The rubber cork is notched to allow recirculation of fluid in a closed circuit.
    2. With another clamp, place a 125 mL flask containing 45 mL of Buffer 2 along with a stopper that has two 1 mL pipettes, one of which is in the liquid near the bottom of the flask and the other which stays above the liquid and blows oxygen into the flask.
      NOTE: Each pipette in the stoppers will have a quick disconnect adaptor attached to the end for easy switching of the tubing. Oxygen will be gently flowing into both flasks via the pipette in the stopper that is not immersed in the liquid.
    3. Set aside two sterile crystallizing dishes.

2. Animal Procedure

  1. Warm up the PBS and Buffer 2 solutions to 42 °C in the water bath and circulate PBS for at least 20 mL/min in the tubing in a closed circuit to keep the liquid lines warm. Immerse any excess tubing in the water bath to remain as close as possible to 42 °C. Drain the male end of the tubing into the 1 L flask containing PBS.
  2. Place a cotton ball on the absorbent underpad and add about 2 mL of 30% isoflurane (made up in polyethylene glycol 200 which decreases the evaporation rate of isoflurane) on the cotton ball using a transfer pipette.
  3. Pick up the mouse by the tail, place it in one of the crystallizing dishes, and then quickly overturn the dish onto the cotton ball so that the mouse has a small space in which to inhale the anesthesia. Observe the breathing rate of the mouse and ensure the mouse is effectively under anesthesia.
    NOTE: The breathing rate should be slower and deeper, the tail flaccid, and the paws nonresponsive to the pinch test under anesthesia; see IACUC guidelines for additional details.
  4. While the mouse is going under anesthesia (this takes 1–2 min), prepare the barrel of a 10 mL syringe by pulling out the plunger and inserting a small cotton ball. Add 1–2 mL of 30% isoflurane with a transfer pipette to the cotton ball inside the barrel and place the barrel open-end down on a table while waiting for the mouse to become unconscious.
  5. Quickly take off the crystallizing dish, flip the mouse on its back and place the syringe barrel over its nose. Double-check the breathing rate, toe pinch, and flaccid tail. Any responses to the toe pinch and flaccid tail indicate that the mouse is not fully under anesthesia. Keep the syringe barrel over the snout to maintain unconsciousness.
  6. Place thumb tacks through the paws of the mouse, with the limbs outstretched in supine position. Wet the abdomen and rib cage with 70% isopropanol or ethanol.
  7. With the straight forceps in one hand, lift up the skin near the base of the abdomen. With scissors in the other hand, cut the tented skin and peritoneum. The incision should be horizontal or across the base of the tented skin. Be sure to cut through all layers of skin and peritoneum in order to gain access to the gut. Cut laterally around the abdomen up to the rib cage on both sides without nicking any of the organs.
  8. Cut off the flap of skin by cutting across the lower rib cage. Move the intestines to the right with the back of the forceps to expose the portal vein.
    NOTE: Bleeding from the animal should be minimal; the animal should still be breathing and under deep anesthesia.
  9. Place the closed curved forceps underneath the portal vein between the liver and superior pancreaticoduodenal vein (Figure 2 arrow).
  10. Open the forceps while underneath the portal vein. Grasp the thread and carefully pull it through so that it is centered underneath the portal vein. Tie an overhand knot around the portal vein without cinching it down.
  11. Place the curved forceps under the portal vein and gently pull it towards the tail of the mouse to straighten out the vein (Figure 3A).
  12. With the catheter in the other hand, place the bevel of the needle face-up and parallel with the lower part of the portal vein near the forceps (Figure 3B).
  13. Gently puncture the vein with the needle (Figure 3C). Ensure the bevel of the needle is in the lumen of the vein. Retract the spring-loaded needle and continue to push the polymer catheter through the vein until the bevel is near the venous branched area. This is within the liver. If the catheter is placed correctly, a back-flow of blood will be visible. (Figure 3D).
  14. Tighten the overhand knot and pull it down on the catheter to help stabilize it. Immediately turn down the pump rate from 20 mL/min to 4 mL/min and cut another major blood vessel for drainage. Cut the aorta abdominalis for optimal results.
  15. Place the male end of the tubing to the female end of the catheter (Figure 4A). Ensure that there are no air bubbles in the line. Be careful that the catheter is not either pushed into the liver or out of the vein. Placement of the thread is not essential, though it helps prevent back-flow out of the vein and helps keep the catheter in the correct position (Figure 4B, C).
  16. Use masking tape to immobilize the tubing onto the underpad. Use the straight forceps to squeeze the effluent blood vessel to inflate the liver a few times to ensure all the blood has drained out (Figure 4D).
    NOTE: Standard laboratory tape may not work; however, masking tape will remain stuck to the underpad, even in wet conditions.

3. Liver Perfusion

  1. While the liver is flushing with PBS, measure out about 24 mg of Collagenase Type IV and place it in the flask containing 45 mL of Buffer 2 in the water bath. Be sure to swirl the liquid in the flask so that the collagenase is fully dissolved and place the flask back in the clamp so that the liquid containing portion of the flask is fully submerged in the water.
  2. Observe the change in color of the liver as it is flushed with PBS. Change the outflow tubing from the 1 L flask to the 125 mL flask. Do not allow air bubbles to flow into the liver.
  3. Once the perfusion buffer reaches the liver, briefly squeeze tight the effluent blood vessel to build up some pressure within the vessel and allow this liquid to fill all lobes of the liver. Be sure not to cut off drainage too long, as that may burst the thin connective tissue surrounding the liver (Glisson's capsule) and destroy the perfusion or flow of liquid within the capillary bed of the liver.
  4. Allow Buffer 2 with collagenase to perfuse through the liver until all 45 mL have flowed through the tissue.
    NOTE: If successful, the Glisson's capsule should be separated from the parenchyma or the liver tissue and the liver itself should appear amorphous.
  5. Add about 10 mL of Buffer 1 to the other crystallizing dish and place it next to the mouse.
  6. Remove the catheter and turn the pump off.
  7. With the straight forceps and scissors, cut the liver from the mouse. If the collagenase digestion was very efficient, it may be necessary to have a clean, sterile spoon on hand to scoop the liver from the mouse and place it in Buffer 1.

Subscription Required. Please recommend JoVE to your librarian.

Representative Results

Figure 1
Figure 1: Schematic representation of the perfusion suite. The flasks are held in place by clamps (not shown); the tubing containing fluid is swapped from the 1L flask to the 125 mL flask during the procedure is represented by the red dotted line. Note, that the oxygen feed does not bubble directly into the solutions in the flasks. The corks should also be notched to allow a closed-circuit fluid flow with the tubing inserted within the notch. This is critical during warm-up of the tubing and for ejection of all air within the tubing. The air bleed is composed of the T-connector which is connected to Tygon tubing and pinch clamps for quick open and closure of the system.

Figure 1
Figure 2: Image of the vasculature of the mouse abdomen. Insertion of the catheter should be just below the gastric and pancreatic vein junctions coming off the portal vein (green dot) and the tip should be placed near the left and right hepatic portal veins (yellow dot) which forms a fork into the main lobes of the liver. Once correct placement is achieved, the catheter should be stabilized with thread using a simple overhand knot. K = kidney, L = liver, SI = small intestine.

Figure 1
Figure 3: Catheter placement in the portal vein. (A) The forceps are used to ensure blood engorgement of the portal vein and to straighten out the vein for catheter placement. (B) The catheter is lined up in parallel with the portal vein with the bevel up. (C) The bevel of the needle within the catheter is inserted into the vein, not through the vein. (D) The needle of the catheter is retracted, and blood will backflow through the catheter as indicated by the tip of the forceps.

Figure 1
Figure 4: Proper liver perfusion. (A) After catheter placement, the female Luer end of the catheter is connecting to the male Luer end (cut from a 1 mL syringe) of the pump tubing. (B) After cutting one of the major descending blood vessels, blood and PBS are drained from the abdomen by slicing the side of mouse with scissors. (C) The liver should blanch while the blood is flushed out and (D) will swell when under pressure by squeezing shut the cut blood vessel with forceps.

Subscription Required. Please recommend JoVE to your librarian.

Materials

Name Company Catalog Number Comments
1 L Erlenmeyer flask Fisher Scientific S63274
250 mL Erlenmeyer flask Fisher Scientific S63271
Silicone tubing  Cole-Parmer 96400-14 This tubing runs from the flasks through the pump to the T connector and then to the 1.0 mL syringe that is connected to the catheter.
Tygon tubing Fisher Scientific R3603 Used as an adaptor between 96400-14 and pipettes and T connector.  This may also be used for the oxygen tubing.
T-connectors Cole-Parmer EW-06294-82
Quick dissconnects Fisher Scientific 6150-0010
Pinch Clamps Fisher Scientific 6165-0002
Masterflex L/S Variable speed Pump; model 7553-70 Cole-Parmer EW-07559-00 Periplastic pump with variable speed
Pump head; model 7014-20 Cole-Parmer EW-07014-20
Glass graduated 1.0 mL pipettes  Fisher Scientific 13-678
Curved non-serrated scissors Fine Science Tools 14069-12
Dumont forceps Fine Science Tools 11252-20
Curved forceps Fine Science Tools 13009-12
10 mL syringe Fisher Scientific 03-377-23 Only barrel of syringe will be needed
Sterlized spoon Home supply store
Cotton ball(s) Home supply store
Polyester sewing thread Home supply store
Masking tape Home supply store
Thumb tacks Home supply store
Styrofoam pad  50 mL conical rack
Cookie/baking sheet Home supply store
Absorbant underpads Fisher Scientific 14-206-64
19 L water bath Fisher Scientific TSCOL19
BD Insyte Autogaurd Shielded IV Catheter 24 guage Becton Dickinson 381412 Plastic cathetar with retractable needle
Crystallizing dishes 100x50 VWR  89000-290
Polystyrene petri dishes Sigma Aldrich P5481-500EA
50 mL conical tubes Fisher Scientific 12-565-270
Graduated pipettes (5 mL) Fisher Scientific 170355
Graduated pipettes (25 mL) Fisher Scientific 170357
EasyStrainer 100 µM Greiner bio-one 542000 100 µm filter
EasyStrainer 40 µM Greiner bio-one 542040 40 µm filter
REAGENTS
Name Compound Grams (g/L) Millimolar (mM)
Buffer 1; pH 7.4 NaCl 8.3 142
KCl 0.5 6.7
HEPES 2.4 10
BSA 15 0.226
Buffer 2; pH 7.4 NaCl 3.9 66.74
KCl 0.5 6.71
CaCl2 0.7 6.31
HEPES 24 100
BSA 15 0.226
Phenol Red 0.01 0.03
PBS; pH 7.4 NaCl 8 137
KCl 0.2 2.7
Na2HPO4-7H2O 1.15 4.3
KH2PO4 0.2 1.4
OTHER REAGENTS
Name Company Catalog Number Comments
Collagenase Type IV Sigma Aldrich C5138
Isoflurane  Abcam ab144581

DOWNLOAD MATERIALS LIST

View Video

Get cutting-edge science videos from JoVE sent straight to your inbox every month.

Waiting X
Simple Hit Counter