$$\rightleftharpoonup{xx}$$
$$\longleftharp{xx}$$,
$$\longrightharp{xx}$$,
The dynamic failure of a material is an important aspect of its overall mechanical behavior, and has relevance to numerous industries including automotive, aerospace, and military to name a few. While failure at low strain-rates is typically studied through conventional tension tests, in which a long thin sample is loaded in tension from the ends, at high strain rates such a geometry/configuration requires a sample to be very small in order to maintain a pseudo-mechanical equilibrium throughout the test. At the appearance of a single crack, the surrounding material will be relaxed, effectively arresting the development of any adjacent failure sites. This limits the number of fractures that can be simultaneously observed in any one experiment, and prevents important information regarding the statistics of failure to be determined.
The expanding cylinder test is a well-established technique for characterizing the manner in which materials fail and fragment under high speed loading. In the test, a cylinder made of the material of interest is uniformly loaded along its inner circumference, launching a stress wave through the wall and causing the cylinder to expand. Soon this radial wave dissipates and a uniform tensile hoop stress around the circumference dominates. As the stress and strain rate is the same around the cylinder the fracture and fragmentation behavior is governed solely by the material’s properties. The test alleviates the aforementioned problem as the typically large sample circumferences promote initiation of multiple failure sites under uniform stress 1.
The main aim in developing this experimental technique was to enable the study of the role of temperature in the fracture and fragmentation behavior of an expanding cylinder. The control of the sample temperature will allow for investigation of how the dynamic tensile strength, fracture mechanism, and fragmentation behavior of the material is affected. For example in metals, an increase in temperature can cause a shift from brittle to ductile fracture, accommodating more plastic work before ultimately failing. Some materials such as Ti-6Al-4V can also exhibit adiabatic shear localization 2. While the sample deforms, the plastic work generates heat. If the rate of softening as a result of this temperature increase is greater than the rate of work hardening from the deformation, an instability can form where a large amount of plastic deformation occurs in a very localized band (adiabatic shear band). This response is promoted in Ti-6Al-4V due to its poor thermal conductivity, and can potentially limit its effectiveness for applications such as lightweight armor.
This new testing approach must satisfy two main criteria. Firstly, the method must produce a radial strain rate on the order of 104 sec-1, typically seen in ballistic and impact events, to allow comparison to previous studies employing more traditional loading schemes. Secondly, the drive mechanism needs to be unaffected by the sample temperature to ensure consistency between experiments. Initial cylinder expansion mechanisms used explosive charges, either simply filling the sample cylinder 3-5 directly or using an intermediate driver. In the latter case a buffer is used 6, where the sample is placed over a steel cylinder that in turn contains an explosive charge. The obvious limitation is that as the sample cylinder contains the drive material (in the form of the explosive) heating the cylinder will also heat the charge. While this may not directly cause initiation of the charge many types of explosive contain a polymeric binder material that will melt out from the sample cylinder. Likewise, some explosives become highly sensitive when cooled. This means that explosive drives are not suitable for temperature study. An alternative method uses the Lorentz force for expansion — the sample is placed over a driver coil 7, 8. A high current is injected into this driver coil (typically heavy gauge copper wire), inducing an opposite current in the sample. These opposing currents have associated magnetic fields which act against each other, the magnetic pressure driving the sample outwards from the inner face. Again, heating the material will adversely affect the copper drive coil inside the sample. Gas guns have been used for cylinder expansion since the late 1970s 9. In these experiments the material used for the insert in the cylinder is a polymer, the drive coming as a result of both the projectile and insert deforming at impact. This insert is typically a rubber or plastic 10, the strength and ductility of which will be severely affected by temperature. Heating will make the insert too soft, and cooling will make it behave in a brittle manner so it fails prematurely.
Unlike previous cylinder expansion techniques, the method described here is the first to provide a repeatable loading drive over a wide range of temperatures (100-1,000 K). Our technique is unique in the fact that the material used for driving the expansion (in our case the projectile) is separate from the cylinder until the point of impact. Consequently, it is unaffected by the initial temperature of the sample cylinder and provides a repeatable load.
The experimental geometry consists of a steel ogive mounted inside the target cylinder, with the tip located about halfway along the length of the cylinder. A single stage light gas gun is then used to launch a polycarbonate projectile with a concave face into the cylinder at velocities up to 1,000 m/sec-1. The axis of the target is cylinder is carefully aligned to the axis of the gas-gun barrel to facilitate a repeatable and uniform load. The impact and subsequent flow of the polycarbonate projectile around the pseudo-rigid steel ogive, drives the cylinder into expansion from the inside wall. The geometry of the ogive insert and the concave face of the projectile were carefully optimized using hydro-code computer simulations to generate the desired expansion of the cylinder. Using 4340 alloy steel for the ogive enables experimentation with the cylinder at temperature as its strength is much higher than the polycarbonate projectile over the temperature range of interest, ensuring the drive mechanism remains consistent. Ogives recovered from heated and cooled experiments only exhibit minimal deformation as a result of the impact.
The heating and cooling of the sample cylinder is accomplished by the installation of temperature control hardware into a machined recess in the rear of the ogive insert. For cooling the sample to cryogenic temperatures (~100 K), the recess in the ogive is sealed with an aluminum cap and liquid nitrogen is flowed through the cavity. As the target cylinder has a large contact area with the ogive the sample is cooled through conduction. To heat the target cylinder to temperatures approaching 1,000 K, a ceramic and NiChrome resistive heater is placed in the ogive recess. A high current power supply provides up to 1 kW, heating the ogive and cylinder. The cylinder and ogive are thermally isolated from the target mount in the single stage gas-gun through the use of MACOR ceramic spacers. The tank is also held under moderate vacuum (<0.5 Torr) during the experiment which aids thermal manipulation.
In order to diagnose the fragmentation process of the cylinder, the experimental design includes multiple channels of frequency-conversion PDV, to measure the expansion velocity at points along the cylinder. PDV is a relatively new 11, optical fiber based interferometry technique which enables the measurement of surface velocities during highly dynamic events. During a PDV measurement, Doppler shifted light reflected from a moving surface of interest using a fiber-optic probe is combined with un-shifted light, creating a beat frequency that is directly proportional to the velocity of the moving surface. Essentially, a PDV system is a fast Michelson interferometer using advances in near-infrared (1,550 nm) communications technology to record beat frequencies in the GHz range. The mounting system for the 100 mm focal length PDV probes used in the current study ensures that they are isolated from the temperature of the cylinder and provides easy alignment. An additional advantage of using the 100 mm focal length probes is that they provide sufficient optical access to enable high speed photography to measure the expansion profile of the whole cylinder. The arrangement and location of the four probes, A-D, along the cylinder is shown in Figure 1. Two high speed cameras are employed here; a high speed video camera Phantom V16.10 operating at 250,000 fps and an IVV UHSi 12/24 framing camera, capturing 24 images. The IVV camera is backlit such that the cylinder is illuminated in silhouette enabling the radially expanding edge of the cylinder to be accurately tracked. The Phantom camera is front illuminated imaging the failure initiation and fragmentation process. The high speed photography can then be correlated with the velocimetry to give strain and strain rate along the full sample. The high speed imaging also allows for an accurate measure of failure strain and the fracture patterns along the surface.
The experimental technique presented in the following protocol section provides a means of controlling the sample temperature in an expanding cylinder experiment, through which different fracture mechanisms may be activated or suppressed. This technique will lead to a more comprehensive understanding of the role of temperature in dynamic loading scenarios.