A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Ultrasound-based Pulse Wave Velocity Evaluation in Mice

14K views

⸱

DOI:

10.3791/54362

⸱

February 14th, 2017

 ,  ,  , 

In This Article

Summary

Arterial stiffness represents a key factor in cardiovascular disease and pulse wave velocity (PWV) can be considered as a surrogate index for arterial stiffness. This protocol describes an image processing algorithm for calculating PWV in mice based on ultrasound image processing that is applicable at different arterial sites.

Abstract

Arterial stiffness can be evaluated by calculating pulse wave velocity (PWV), i.e., the speed with which the pulse wave travels in a conduit vessel. This parameter is being increasingly investigated in small rodent models in which it is used for assessing alterations in vascular function related to particular genotypes/treatments or for characterizing cardiovascular disease progression. This protocol describes an image processing algorithm which leads to non-invasive arterial PWV measurement in mice using ultrasound (US) images only. The proposed technique has been used to assess abdominal aorta PWV in mice and evaluate its age-associated changes.

Abdominal aorta US scans are obtained from mice under gaseous anesthesia using a specific US device equipped with high-frequency US probes. B-mode and Pulse-Wave Doppler (PW-Doppler) images are analyzed in order to obtain diameter and mean velocity instantaneous values, respectively. For this purpose, edge detection and contour tracking techniques are employed. The single-beat mean diameter and velocity waveforms are time aligned and combined in order to achieve the diameter-velocity (lnD-V) loop. PWV values are obtained from the slope of the linear part of the loop, which corresponds to the early systolic phase.

With the present approach, anatomical and functional information about the mouse abdominal aorta can be non-invasively achieved. Requiring the processing of US images only, it may represent a useful tool for the non-invasive characterization of different arterial sites in the mouse in terms of elastic properties. The application of the present technique can be easily extended to other vascular districts, such as the carotid artery, thus providing the possibility to obtain a multi-site arterial stiffness assessment.

Introduction

Mouse models are increasingly employed for the investigation of cardiovascular disease (CVD) and particularly used in longitudinal studies which allow the characterization of different phases of disease development1. Elastic properties of large arteries are related to different pathological conditions; from a technical point of view, arterial stiffness can be assessed by measuring pulse wave velocity (PWV), which represents the speed with which the pulse wave travels in a conduit vessel2. Because of its clinical significance, it is increasingly measured even in preclinical small animal models3.

Access restricted. Please log in or start a trial to view this content.

Protocol

Animal experiments were performed in accordance with the European Directive (2010/63/UE) and the Italian law (D.Lvo 26/2014), and it followed principles of laboratory animal care. The Local Ethical Approval Panel approved the study.

1. Imaging Procedure

  1. Place the mouse in an anesthesia induction chamber filled with 2.5% isoflurane in 1 L/min pure oxygen. Verify the depth of anesthesia by unresponsiveness to toe pinch.
  2. Place the animal on a temperature controlled board in a supine position. Moisten the animal's eyes with eye salve, in order to avoid them running dry. Supply anesthetic gas flow (1.5% isoflurane) by placing the mouse's nose i....

Access restricted. Please log in or start a trial to view this content.

Results

The proposed approach has been applied to mice abdominal aorta in a previous study11. The following figures show the results of the application of the described approach on real mice images. These data are from a single animal (wild type mice, 13 weeks old, strain: C57BL6, weight: 33 g) In particular, Figure 1 represents the result of the analysis of the US images. Edge detection and contour tracking techniques applied to B-mode images acquired wit.......

Access restricted. Please log in or start a trial to view this content.

Discussion

In this study, an image processing algorithm based on the lnD-V loop for PWV assessment in mice has been described in detail. The proposed approach is based on the processing of US images only and, thus, could represent a valid alternative to existing techniques6,13 for the evaluation of arterial stiffness in mouse models. In fact, conversely to invasive methods6 which are based on the acquisition of intra-arterial pressure signals and req.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have nothing to disclose.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
VEVO2100FUJIFILM VisualSonics Inc, Toronto, Canadamicro-ultrasound equipment
MS250 Ultrasound ProbeFUJIFILM VisualSonics Inc, Toronto, Canadamicro-ultrasound probe
EKV SoftwareFUJIFILM VisualSonics Inc, Toronto, CanadaSoftware
Matlab R2015a MathWorks Inc, Natick, MA, USASoftware
Conductive PasteChosen by the operatorLaboratory material
Petroleum JellyChosen by the operatorLaboratory material
Depilatory CreamChosen by the operatorLaboratory material
Acoustic Coupling Gel Chosen by the operatorLaboratory material
Developed Matlab SoftwareThe authors are willing to collaborate with those researchers who are interested in the software and to make the software available under their supervision

References

  1. Zaragoza, C., et al. Animal Models of Cardiovascular Diseases. J Biomed Biotechnol. 2011, 497-841 (2011).
  2. Laurent, S., et al. Expert consensus document on arterial stiffness: methodological issues and clinical applications. Eur Heart J.

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Ultrasound ImagingAbdominal AortaEdge DetectionContour TrackingDiameter Velocity LoopECG Gated AcquisitionHigh Frame RateArterial StiffnessMouse Model