Back to chapter

16.8:

Indicators

JoVE Core
Chemistry
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
JoVE Core Chemistry
Indicators

Languages

Share

Indicators change color depending on pH and can be used to monitor the pH of a solution.  A pH indicator contains a weak acid, represented by HIn, which changes color when converted to its conjugate base, the In ion. The color changes over the indicator’s pH interval, which depends on its pKa. If a solution has a pH below the pKa of the indicator, the hydronium concentration is high. The equilibrium of the reaction shifts towards the left, increasing the concentration of HIn. When a base is added, the concentration of hydronium decreases. This pH change converts HIn into the In ion, and the solution’s color shifts. The HIn color dominates when the pH is at least one lower than the pKa; the In ion color dominates when the pH is at least one higher, and the color is a mix at pHs in between. There are a variety of pH indicators which can be used to monitor the pH that change color over distinct pH ranges. The point at which an indicator changes color is called the endpoint. The ideal indicator for a titration has an endpoint near the equivalence point.   The titration curve of a strong acid and base is steep due to the rapid pH change near the equivalence point. These titrations can use a relatively broad range of indicators. During the titration of 0.1 molar hydrochloric acid with 0.1 molar sodium hydroxide, the pH quickly increases from 3 to 11. Either phenolphthalein, an indicator with the pH interval of 8.3 to 10, or methyl red, an indicator with an interval of 4.2 to 6, could be used here as their endpoints overlap with the steep portion of the curve.  In contrast, a titration involving a weak acid or base has a less steep curve than one with only a strong acid and a strong base; therefore, a relatively narrow range of indicators can be used. During the titration of  0.1 molar acetic acid with 0.1 molar sodium hydroxide, the pH increases quickly from 7 to 11. Phenolphthalein can be used here as its endpoint overlaps with the equivalence point, but methyl red would be an ineffective indicator.

16.8:

Indicators

Certain organic substances change color in dilute solution when the hydronium ion concentration reaches a particular value. For example, phenolphthalein is a colorless substance in any aqueous solution with a hydronium ion concentration greater than 5.0 × 10−9 M (pH < 8.3). In more basic solutions where the hydronium ion concentration is less than 5.0 × 10−9 M (pH > 8.3), it is red or pink. Substances such as phenolphthalein, which can be used to determine the pH of a solution, are called acid-base indicators. Acid-base indicators are either weak organic acids or weak organic bases.

The equilibrium in a solution of the acid-base indicator methyl orange, a weak acid, can be represented by an equation in which we use HIn as a simple representation for the complex methyl orange molecule:

Eq1

The anion of methyl orange, In, is yellow, and the nonionized form, HIn, is red. When we add acid to a solution of methyl orange, the increased hydronium ion concentration shifts the equilibrium toward the nonionized red form, in accordance with Le Châtelier’s principle. If we add base, we shift the equilibrium towards the yellow form. This behavior is completely analogous to the action of buffers.

The perceived color of an indicator solution is determined by the ratio of the concentrations of the two species In and HIn. If most of the indicator (typically about 60−90% or more) is present as In, the perceived color of the solution is yellow. If most is present as HIn, then the solution color appears red. The Henderson-Hasselbalch equation is useful for understanding the relationship between the pH of an indicator solution and its composition (thus, perceived color):

Eq1

In solutions where pH > pKa, the logarithmic term must be positive, indicating an excess of the conjugate base form of the indicator (yellow solution). When pH > pKa, the log term must be negative, indicating an excess of the conjugate acid (red solution). When the solution pH is close to the indicator pKa, appreciable amounts of both conjugate partners are present, and the solution color is that of an additive combination of each (yellow and red, yielding orange). The color change interval (or pH interval) for an acid-base indicator is defined as the range of pH values over which a change in color is observed, and for most indicators this range is approximately pKa ± 1.

There are many different acid-base indicators that cover a wide range of pH values and can be used to determine the approximate pH of an unknown solution by process of elimination. Universal indicators and pH paper contain a mixture of indicators and exhibit different colors at different pHs.

This text is adapted from Openstax, Chemistry 2e, Section 14.7: Acid-Base Titrations.

Suggested Reading

Coleman, William F. "Molecular models of indicators." Journal of Chemical Education 87 no.1, (2008):1152 https://pubs.acs.org/doi/pdf/10.1021/ed800038w.