Total retinal blood flow is measured by Doppler optical coherence tomography and semi-automated grading software.

Abstract

Noncontact retinal blood flow measurements are performed with a Fourier domain optical coherence tomography (OCT) system using a circumpapillary double circular scan (CDCS) that scans around the optic nerve head at 3.40 mm and 3.75 mm diameters. The double concentric circles are performed 6 times consecutively over 2 sec. The CDCS scan is saved with Doppler shift information from which flow can be calculated. The standard clinical protocol calls for 3 CDCS scans made with the OCT beam passing through the superonasal edge of the pupil and 3 CDCS scan through the inferonal pupil. This double-angle protocol ensures that acceptable Doppler angle is obtained on each retinal branch vessel in at least 1 scan. The CDCS scan data, a 3-dimensional volumetric OCT scan of the optic disc scan, and a color photograph of the optic disc are used together to obtain retinal blood flow measurement on an eye. We have developed a blood flow measurement software called "Doppler optical coherence tomography of retinal circulation" (DOCTORC). This semi-automated software is used to measure total retinal blood flow, vessel cross section area, and average blood velocity. The flow of each vessel is calculated from the Doppler shift in the vessel cross-sectional area and the Doppler angle between the vessel and the OCT beam. Total retinal blood flow measurement is summed from the veins around the optic disc. The results obtained at our Doppler OCT reading center showed good reproducibility between graders and methods (<10%). Total retinal blood flow could be useful in the management of glaucoma, other retinal diseases, and retinal diseases. In glaucoma patients, OCT retinal blood flow measurement was highly correlated with visual field loss (R2>0.57 with visual field pattern deviation). Doppler OCT is a new method to perform rapid, noncontact, and repeatable measurement of total retinal blood flow using widely available Fourier-domain OCT instrumentation. This new technology may improve the practicality of making these measurements in clinical studies and routine clinical practice.

Protocol

1. Protocol Text

  1. Patients are scanned by RTVue Fourier-domain optical coherence tomography (OCT) system (Optovue Inc., Fremont, CA, USA) using the circumpapillary double-circular scan (CDCS) and the 3D optic disc scan.
    1. The CDCS pattern consists of two concentric circles around the optic nerve head. The inner ring diameter is 3.40 mm and the outer ring diameter is 3.75 mm. This pattern transects all branch retinal arteries and veins emanating from the optic nerve head. The double circles are performed 6 times in a single scan to cover about 2 cardiac cycles. To calculate Flow velocity, Doppler shift and Doppler will be estimated on vessel de....

Access restricted. Please log in or start a trial to view this content.

Discussion

Blood flow abnormalities occur in glaucoma and vascular diseases of the retina such as diabetic retinopathy.6-10 Volumetric measurement of retinal blood flow gives valuable information about the disease process.4-6,11,12 DOCTORC provides a practical way to estimate total retinal blood flow based on the measurements in individual vessels determined by Doppler OCT using the double circle scan pattern.1-5

The mean total retinal blood flow measured by Doppler OCT .......

Access restricted. Please log in or start a trial to view this content.

Disclosures

Dr. Huang receives grant support, patent royalty, stock options, travel support and lecture fees from Optovue, Inc.; Dr. Tan and Dr. Wang receives patent royalty and grant support from Optovue, Inc.; Dr. Koduru and Dr. Sadda received grant support from Optovue.

Acknowledgements

This study is supported by NIH grant RO1 013516 and a grant form Optovue.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
RTVue Fourier Domain optical coherence tomography OptovueN/AVersion 6.1.0.21 or higher Installed with blood flow double ring scan pattern

References

  1. Wang, Y., Bower, B. A., Izatt, J. A., Tan, O., Huang, D. Retinal blood flow measurement by circumpapillary Fourier domain Doppler optical coherence tomography. J. Biomed. Opt. 13, 064003(2008).
  2. Wang, Y.

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Doppler OCTRetinal Blood FlowDual Angle ProtocolCircumpapillary Double Circular ScanVessel Detection AlgorithmBlood Flow Grading SoftwareTotal Retinal Blood FlowRetinal Vein AnalysisGlaucoma Diagnosis