There are 14,578 patients on the waiting list for liver transplantation and approximately 7,000 transplants are performed per year1,2. In response to this significant donor shortage, the criteria for liver donors have expanded; these are often referred to as marginal organs or extended criteria donors and are expected to perform less well after transplantation than standard criteria allografts, with higher rates of primary graft dysfunction and delayed graft function3,4,5,6. As a result, NEVLP has been introduced as a method to evaluate and modify organ function6,7. We have designed a rat model of NEVLP and used this model to demonstrate one of its important potential applications – the testing of novel molecule additives to liver perfusate.
NEVLP has been evaluated in both murine (rat) and porcine models, as well as in discarded human organs6,8,9. The results of the first human trials of NEVLP have also recently been published10. Although hypothermic machine perfusion has clearly become the standard for kidney preservation, the temperature at which liver machine perfusion should occur is still controversial. NEVLP has many proposed advantages in comparison to hypothermic and subnormothermic perfusion. These include reduced preservation injury, restoration of normal organ function under physiologic conditions, the ability to assess organ performance, and as a platform for organ repair, remodeling, and modification7,11,12,13,14,15,16,17.
A significant number of studies have been completed using porcine NEVLP models. Although these models are comparatively inexpensive when considering models using discarded human organs or human clinical trials, they are very expensive when compared to our small animal NEVLP model. A significant component of the per experiment cost is the perfusate. We are able to complete a 4 h perfusion with 300 mL of perfusate at a relatively low cost. Additionally, the cost of small animals including rats is very low in comparison to the cost of pigs.
In comparison to other models of NEVLP in the rat, the model presented here is relatively simple to implement and has a broad range of applications. The perfusion circuit can be seen in Figure 1. The perfusate starts in the perfusate reservoir (1), which is a water jacketed container. Perfusate is pulled from the reservoir by a roller pump (2) and pushed into a windkessel (3) and then the oxygenator (4). The oxygenator is set for countercurrent gas and perfusate flow to provide maximum gas exchange. The perfusate then proceeds to a heating coil (5) inside the perfusion chamber to ensure it is at physiologic temperature, and a bubble trap (6) to prevent perfusion of air bubbles There are pre-organ (7) and post-organ (8) sample ports, which allow the perfusate to be sampled. The perfusate then enters the liver through the portal vein cannula. The portal vein cannula is attached to a pressure monitor that charts the values on the data collection software. The perfusate then exits the liver through the IVC cannula and flows into the pressure equalizer block (9). Finally, the perfusate is pulled from the pressure block back through the roller pump and emptied into the reservoir. This model includes continuous perfusion to the portal vein and leaves out the pulsatile flow to the hepatic artery and dialysis used in some other models, each of which requires a separate and additional circuit, but have previously been demonstrated to not be required9,13.
To explore the addition of a novel therapeutic molecule to the perfusate, we chose the enzyme catalase. Catalase is an endogenous ROS scavenger that is part of the cells internal defense mechanism to mitigate the effects of ROS18. Catalase expression is increased in hepatic ischemia reperfusion injury19. Experimental addition of catalase has been demonstrated to decrease ischemia-reperfusion in the eye, brain, and lung20,21,22,23,24. Pegylation has been shown to target catalase to the endothelium and aid in catalase uptake into endothelial cells25. PEG-CAT has been administered systemically with limited efficacy in reducing hepatic ischemia-reperfusion injury; however, we hypothesized that adding PEG-CAT to an isolated organ perfusion circuit would lead to improved results26,27,28. Here, we add PEG-CAT to our base perfusate and demonstrate its ability mitigate liver preservation injury.