Longitudinal evaluation of cardiac function in large animal models is a robust research methodology commonly used for the assessment of the effects of novel therapies for treating ischemic and non-ischemic cardiomyopathy. Amongst the several cardiovascular imaging techniques available for preclinical research, echocardiography has been used extensively because of its non-invasive and portable characteristics. In experienced hands, echocardiography is also a very reproducible imaging technique to study cardiac anatomy as well as systolic and diastolic function of the heart.
Large preclinical animal models such as pigs, dogs and rabbits, are paramount for preclinical translational research1,2,3. Indeed, the potential benefit of novel therapies such as cardiac regenerative medicine in the setting of cardiomyopathy requires extensive hypothesis testing in large preclinical models before they can be considered for human use2,4. Compared to other large preclinical models, the rabbit model offers some advantages, including its low maintenance cost, which is comparable to that of mice and rats. However, in contrast to mice and rats, the Ca+2 transport system and cardiac electrophysiology are similar in rabbits as those of humans, and those of other large animal models such as dogs and pigs, thus increasing the translational potential of the rabbit model1,5. Therefore, the rabbit, as a large experimental preclinical model, has an exceptional balance of cost and reproducibility for preclinical translational research.
The rabbit has the additional benefit of its amenability for echocardiographic imaging using clinical ultrasound units routinely used in human and veterinary patients, thus taking advantage of the superiority of harmonic imaging and state-of-the-art technology. For this, sector transducers (also known as phase array) of relatively high frequency (up to 12 MHz), such as those used in neonatal/pediatric cardiology, are preferred. Echocardiographic examination in the rabbit preclinical model allows the complete evaluation of systolic and diastolic function using multiple views and different modes available in modern echocardiographic units (e.g. continuous wave Doppler (CWD), pulsed-wave Doppler (PWD), and Tissue Doppler imaging (TDI)).
Echocardiography is an operator-dependent technique and therefore requires extensive training and core knowledge of the technique in accord with international guidelines. Part of this training can be facilitated with the visualization of videos explaining in detail how different echocardiographic views can be obtained. The achievement of high competency in echocardiographic imaging, as well as development of a standardized protocol and correct technique, are essential to minimize the influence of the operator and to generate reliable quantitative data, as required in rigorous scientific research.
Some considerations are necessary regarding the system and laboratory setup used for echocardiography in rabbits and other large animal models. For a standard transthoracic echocardiographic evaluation of cardiac function, the ultrasound system must include the following modalities: bi-dimensional mode (B-mode or 2D), motion mode (M-mode), color Doppler, as well as CWD, PWD and TDI. Moreover, the machine should have full cardiac analysis and measurement software installed, as well as sufficient internal hard drive space to store enough high quality digital still images and video loops for offline analysis. Some systems use linear array transducers; however, for the best imaging of the heart, phased array sector transducers with a small scan head diameter are preferred, because these allow an easier passage of the ultrasound waves through the narrow intercostal spaces. For rabbits, we use relatively high frequency transducers (up to 12 MHz). The position of the animal for imaging is of utmost importance to acquire good quality images. Thus, both right and left lateral recumbent positions are recommended to obtain all standard imaging planes during an echocardiographic examination. For this, a table with a notch that coincides with the cardiac area of the chest is advisable (Figure 1A). This notched table facilitates the access with the transducer to the area of the chest that will be scanned, and therefore allows free mobility of the hand of the operator whist maintaining the best scanning position of the animal. Positioning the animal in a lateral recumbent position results in a fall of the heart towards the transducer and elevation of the lungs, as well as widening the access window of the ultrasound beam through the intercostal spaces, thus improving overall imaging quality (Figure 1A). The echocardiographic examination should be performed in a blinded fashion and following the guidelines of the Echocardiography Committee of the American College of Veterinary Internal Medicine and the American Society of Echocardiography/European Association for Cardiovascular Imaging6,7,8.
Part of our scientific team is associated with the Cardiology Service of a Veterinary Teaching Hospital that attends daily to veterinary patients (e.g. dogs and cats), for which it has the relevant training and accreditation in veterinary cardiology and echocardiography, and its different imaging modalities, as well as extensive experience in imaging different sizes of animal patients and thoracic conformations with this technique. In addition, we commonly use echocardiography for longitudinal evaluation of cardiac function in a rabbit model of cardiomyopathy induced by anthracyclines9. Here, we describe a step by step echocardiography protocol for evaluation of cardiac function using a clinical ultrasound unit in a large preclinical model such as the rabbit. This protocol is adapted for current international guidelines8, and includes practical recommendations based on our own experiences in clinical and experimental settings.