Name | Company | Catalog Number | Comments |
Micro air pump | Smart Products, Inc. | AP-2P02A | Max pressure = 6.76 psi; 1.301” x 0.394” x 0.650”, 0.28 oz (8 g); available direct from Smart Products |
Differential pressure sensor | Honeywell International, Inc. | ASDX015D44R | Range of 0-15 psi; 0.974" x 0.550" x 0.440", 0.09 oz (2.565 g); suppliers include Digi-Key and Mouser Electronics |
Rigid plastic vial (small size) | Loritz & Associates, Inc. | 55-05 | Polystyrene; ID 0.81" (20.6 mm), IH 2.06" (52.4 mm); available direct from LA Container Inc.; similar product available from Dynalab Corp. |
latex examination gloves | dynarex corporation | 2337 | Middle finger used for latex diaphragm in fluid source vial. Other brands (e.g., Aurelia ® Vibrant ™) acceptable. |
Optical glue | Norland Products | NOA 88 | Low outgassing adhesive; available direct from Norland; Also available from Edmund Optics Inc. |
3-way solenoid valves | The LEE Company | LHDA0531115H | Gas valves, but can function with liquid; 1.29" L, 0.28" D. Discontinued product. Similar products available from The LEE Company. |
Volumetric water flowmeter | OMEGA Engineering inc. | FLR-1602A | Non-contacting flow rate meter strongly preferred. We recommend SENSIRION LG16 OEM Liquid Flow Sensor for flow rates from nl/min up to 5 ml/min. |
PCD-mini photon detector | Sensl | PCDMini-00100 | For fluorescence detection; available direct from Sensl |
Accelerometer | Crossbow Technology, Inc. | CXL02LF3 | 3-demensional force detection. Supplied to DMI by NASA. Similar product available from Vernier Software & Technology, LLC. |
Stereomicroscope | AmScope | SE305R-AZ-E | |
CCD Camera | Thorlabs | DCU223C | 1,024 x 768 Resolution, Color, USB 2.0; available direct from Thorlabs |
USB and Trigger Cable (In/Out) for CCD Camera | Thorlabs | CAB-DCU-T1 | Available direct from Thorlabs |
Microbore tubing | Saint-Gobain Corporation | AAD04103 | Tygon®; ID 0.02", OD 0.06", 500 ft, 0.02" wall. Suppliers: VWR, Thermo Fisher Scientific Inc. |
Hollow steel pins | New England Small Tube | (Custom) | 0.025" OD, 0.017" ID, 0.500” L, stainless steel tube, type 304, cut, deburred, passivated; enable microbore tubing connections, chip tubing connections |
Slide clamp | World Precision Instruments, Inc. | 14042 | Available direct from World Precision Instruments |
Leur adaptor pieces | World Precision Instruments, Inc. | 14011 | Available direct from World Precision Instruments |
Silicon wafer | Addison Engineering, Inc. | 6" diameter; for SU-8 mold fabrication | |
Polydimethylsiloxane (PDMS) elastomer curing agent | Dow Corning | 3097358-1004 | Supplier: Global Industrial SLP, LLC |
Needle (23 gauge), bevel tip | Terumo Medical Corporation | NN-2338R | Ultra thin wall; 23 G x 1.5"; 22 G also usable; suppliers: Careforde, Inc., Port City Medical |
Dispensing needle (23 gauge), blunt tip | CML Supply | 901-23-100 | 23 G x 1"; available from CML Supply |
Cover glass | Thermo Fisher Scientific, Inc. | 12-518-105E | Gold Seal™ noncorrosive borosilicate glass; for PDMS chip cover; 24 x 60 mm; available from Thermo Fisher Scientific, Inc. |
Vacuum pump | Mountain | MTN8407 | For degassing PDMS; supplier: Ryder System, Inc. |
Vacuum chamber | Thermo Fisher Scientific, Inc. | 5311-0250 | Nalgene™ Transparent Polycarbonate; available from Thermo Fisher Scientific, Inc. |
Plasma cleaner | Harrick Plasma | PDC-32G | |
Hand magnifier | Mitutoyo | 183-131 | Use in reverse direction to enable viewing at ~15". |
Ethanol | CAROLINA | 861283 | For chip cleaning. Dilute to 70% using millipore water. |
Water purification system | Thermo Fisher Scientific, Inc. | D11901 | Available direct from Thermo Fisher Scientific, Inc. |
Optomechanical translation mounts | Thorlabs | K6X | 6-Axis Kinematic Optic Mount; discontinued product; new product (K6XS) available direct from Thorlabs |
Laptop | Hewlett-Packard | VP209AV | HP Pavilion Laptop running Windows 7 |
Laptop tray (spring loaded) | National Products, INC. | RAM-234-3 | RAM Tough-Tray™. Can accommodate 10 to 16 inch wide laptops. |
USB splitter | Connectland Technology Limited | 3401167 | |
USB Data Acquisition Cards (8 analog input, 12 digital I/O) | National Instruments | NI USB-6008 | 12-Bit, 10 kS/s Low-Cost Multifunction DAQ |
USB Data Acquisition Cards (16 analog input, 32 digital I/O) | National Instruments | NI USB-6216 | 16-Bit, 400 kS/s Isolated M Series MIO DAQ, Bus-Powered |
Control/acquisition Software | National Instruments | LabVIEW 2009 | Custom coded National Instruments (NI) LabVIEW |
3D Solid Modeling Software | Dassault Systèmes SolidWorks Corp. | SolidWorks 2011 | |
2D Modeling Software | AUTODESK | AutoCAD LT 2008 | |
Vertical equipment rack | (NASA provided) | N/A | |
Solid aluminum optical breadboard | Thorlabs | MB2424 | 24" x 24" x 1/2", 1/4"-20 Taps; available direct from Thorlabs |
Industrial grade steel and hardener | The J-B Weld Company | J-B Weld Steel Reinforced Epoxy Glue | |
Micro-hematocrit capillary | Fisher Scientific | 22-362-574 | inner diamter 1.1 to 1.2 mm |
1 ml syringes | Henke-Sass, Wolf | 4010.200V0 | NORM-JECT®; supplier: Grainger, Inc. |
Human red blood cells | Innovative Research | IPLA-WB3 | Tested and found negative by supplier for: HBsAg, HCV, HIV-1, HIV-2, HIV-1Ag or HIV 1-NAT, ALT, and syphilis by FDA-Approved Methods. Because no test methods can guarantee with 100% certainty the absence of an infectious agent, human derived products should be handled as suggested in the U.S. Department of Health and Human Services Manual on BIOSAFETY IN MICROBIOLOGICAL AND BIOMEDICAL LABORATORIES, FOR POTENTIALLY INFECTIOUS HUMAN SERUM OR BLOOD SPECIMENS |
Phosphate buffered saline concentrate | P5493 | SIGMA | 10x; diluted to 1x |
Tween | P9416 | SIGMA | TWEEN® 20 |
Centrifuge | LW Scientific | STRAIGHT8-5K | Swing-Out 8-place Centrifuge. Available through authorized dealers. Other centrifuges available direct from LW Scientific. |
HD video recorder | Sony | MHS-CM5 | |
Orange fluorescent nucleic acid stain | Invitrogen | S-11364 | SYTO® 83 Orange Fluorescent Nucleic Acid Stain. Stored in DMSO solvent. Always wear reccommended Personal Protective Equipment. No special handling advice required. |
Fluorescent counting beads | Invitrogen | MP 36950 | CountBright™ Absolute Counting Beads. Always wear reccommended Personal Protective Equipment. No special handling advice required. |
References
- Thomas, R. A., Krishan, A., Robinson, D. M., Sams, C., Costa, F. NASA/American Cancer Society High-Resolution Flow Cytometry Project-I. Cytometry. 43, 2-11 (2001).
- Wen, J., Krishan, A., Thomas, R. A. NASA/American Cancer Society High-Resolution Flow Cytometry Project - II. Effect of pH and DAPI concentration on dual parametric analysis of DNA/DAPI fluorescence and electronic nuclear volume. Cytometry. 43, 12-15 (2001).
- Krishan, A., Wen, J., Thomas, R. A., Sridhar, K. S., Smith, W. I. NASA/American Cancer Society High-Resolution Flow Cytometry Project - III. Multiparametric analysis of DNA content and electronic nuclear volume in human solid tumors. Cytometry. 43, 16-22 (2001).
- Cram, L. S. Spin-offs from the NASA space program for tumor diagnosis. Cytometry. 43, 1 (2001).
- Crucian, B., Sams, C. Reduced gravity evaluation of potential spaceflight-compatible flow cytometer technology. Cytometry B Clin. Cytom. 66 (1), 1-9 (2005).
- Shi, W., Kasdan, H. L., Fridge, A., Tai, Y. -C. Four-part differential leukocyte count using μflow cytometer. 2010 IEEE 23rd International Conference on Micro Electro Mechanical Systems. 13 (7), 1019-1022 (2010).
- Tai, Y. -C., Ho, C. -M., Kasdan, H. L. In-Flight Blood Analysis Technology for Astronaut Health Monitoring NASA Human Research Program Investigators’ Workshop. , Found at: http://www.dsls.usra.edu/meetings/hrp2010/pdf/ExMC/1018Tai.pdf (2010).
- Shi, W., Guo, L. W., Kasdan, H., Fridge, A., Tai, Y. -C. Leukocyte 5-part differential count using a microfluidic cytometer. 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference. , 2956-2959 (2011).
- Shi, W., Guo, L., Kasdan, H., Tai, Y. -C. Four-part leukocyte differential count based on sheathless microflow cytometer and fluorescent dye assay. Lab Chip. 13 (7), 1257-1265 (2013).
- Dubeau-Laramée, G., Rivière, C., Jean, I., Mermut, O., Cohen, L. Y. Microflow1, a sheathless fiber-optic flow cytometry biomedical platform: Demonstration onboard the international space station. Cytometry A. , (2013).
- NASA/JSC Aircraft Operations: C-9B Flight Trajectory. , Found at: http://jsc-aircraft-ops.jsc.nasa.gov/Reduced_Gravity/trajectory.html Forthcoming.
- Crucian, B., Quiriarte, H., Guess, T., Ploutz-Snyder, R., McMonigal, K., Sams, C. A Miniaturized Analyzer Capable of White-Blood-Cell and Differential Analyses During Spaceflight. Lab Medicine. 44 (4), 304-331 (2013).
- Rehnberg, L., Russomano, T., Falcão, F., Campos, F., Everts, S. N. Evaluation of a novel basic life support method in simulated microgravity. Aviat. Space. Environ. Med. 82 (2), 104-110 (2011).
- Pump, B., Videbaek, R., Gabrielsen, A., Norsk, P. Arterial pressure in humans during weightlessness induced by parabolic flights. J. Appl. Physiol. 87 (3), 928-932 (1999).
- Strauch, S. M., Richter, P., Schuster, M., Häder, D. The beating pattern of the flagellum of Euglena gracilis under altered gravity during parabolic flights. J. Plant Physiol. 167 (1), 41-46 (2010).
- Sams, C. F., Crucian, B. E., Clift, V. L., Meinelt, E. M. Development of a whole blood staining device for use during space shuttle flights. Cytometry. 37 (1), 74-80 (1999).
- Smith, S. M., Davis-Street, J. E., Fontenot, T. B., Lane, H. W. Assessment of a portable clinical blood analyzer during space flight. Clin. Chem. 43, 1056-1065 (1997).
- Weigl, B. H., Kriebel, J., Mayes, K. J., Bui, T., Yager, P. Whole Blood Diagnostics in Standard Gravity and Microgravity by Use of Microfluidic Structures (T-Sensors). Microchimica Acta. 131 (1-2), 75-83 (1999).
- Revolutionizing Medical Technology for Earth and Space. Canadian Space Agency. , Found at: http://www.asc-csa.gc.ca/eng/media/backgrounders/2012/0229.asp (2012).
- Peytavi, R. Microfluidic device for rapid (<15 min) automated microarray hybridization. Clin. Chem. 51, 1836-1844 (2005).
- Groemer, G. E. The feasibility of laryngoscope-guided tracheal intubation in microgravity during parabolic flight: a comparison of two techniques. Anesthesia and analgesia. 101 (5), 1533-1535 (2005).
- Johnston, S. L., Campbell, M. R., Billica, R. D., Gilmore, S. M. Cardiopulmonary resuscitation in microgravity: efficacy in the swine during parabolic flight. Aviat. Space Environ. Med. 75 (6), 546-550 (2004).
- Panait, L., Broderick, T., Rafiq, A., Speich, J., Doarn, C. R., Merrell, R. C. Measurement of laparoscopic skills in microgravity anticipates the space surgeon. Am. J. Surg. 188 (5), 549-552 (2004).
- Kirkpatrick, A. W. Intraperitoneal gas insufflation will be required for laparoscopic visualization in space: a comparison of laparoscopic techniques in weightlessness. J. Am. Coll. Surg. 209 (2), 233-241 (2009).
- Campbell, M. R. Endoscopic surgery in weightlessness: the investigation of basic principles for surgery in space. Surg. Endosc. 15 (12), 1413-1418 (2001).
- Caiani, E. G., Sugeng, L., Weinert, L., Capderou, A., Lang, R. M., Vaïda, P. Objective evaluation of changes in left ventricular and atrial volumes during parabolic flight using real-time three-dimensional echocardiography. J. Appl. Physiol. 101 (2), 460-468 (2006).
- Ansari, R., Manuel, F. K., Geiser, M., Moret, F., Messer, R. K., King, J. F., Suh, K. I. Measurement of choroidal blood flow in zero gravity. Ophthalmic technologies XII : 19-20 January 2002, San Jose, USA. Manns, F., S derberg, P. G., Ho, A. , SPIE. Bellingham, Wash. 177-184 (2002).
- Foldager, N. Central venous pressure in humans during microgravity. J. Appl. Physiol. 81 (1), 408-412 (1996).
- Hausmann, N. Cytosolic calcium, hydrogen peroxide and related gene expression and protein modulation in Arabidopsis thaliana cell cultures respond immediately to altered gravitation: parabolic flight data. Plant Biol. (Stuttg). 16 (1), 120-128 (2014).
- Thiel, C. S. Rapid alterations of cell cycle control proteins in human T lymphocytes in microgravity). Cell Commun. Signal. 10 (1), 1 (2012).
- Tsuda, T., Kitagawa, S., Yamamoto, Y. Estimation of electrophoretic mobilities of red blood cells in 1-G and microgravity using a miniature capillary electrophoresis unit. Electrophoresis. 23, 2035-2039 (2002).
- Paul, A. -L., Manak, M. S., Mayfield, J. D., Reyes, M. F., Gurley, W. B., Ferl, R. J. Parabolic flight induces changes in gene expression patterns in Arabidopsis thaliana. Astrobiology. 11 (8), 743-758 (2011).
- Zeredo, J. L., Toda, K., Matsuura, M., Kumei, Y. Behavioral responses to partial-gravity conditions in rats. Neurosci. Lett. 529 (2), 108-111 (2012).
- Taube, J. S., Stackman, R. W., Calton, J. L., Oman, C. M. Rat head direction cell responses in zero-gravity parabolic flight. J. Neurophysiol. 92 (5), 2887-2897 (2004).
- Hilbig, R. Effects of altered gravity on the swimming behaviour of fish. Adv. Space Res. 30 (4), 835-841 (2002).
- FAST Flight Week. Nasa.gov: Office of the Chief Technologist. , Found at: http://www.nasa.gov/offices/oct/crosscutting_capability/flight_opportunities/fast/09_27_10_flight_week_feature.html Forthcoming.
- Deng, J. Harvard Center for Nanoscale Systems Standard Operating Procedure: SOP031 (SU-8 Photolithography Process). , Vers. 2.6, Found at: http://www.cns.fas.harvard.edu/facilities/docs/SOP031_r2_6_SU-8%20photolithography%20process.pdf (2010).
- Yang, J., Qi, L., Chen, Y., Ma, H. Design and Fabrication of a Three Dimensional Spiral Micromixer. Chinese J. Chem. 31, 209-214 (2013).
- Zhang, K. Realization of planar mixing by chaotic velocity in microfluidics. Microelectron. Eng. 88, 959-963 (2011).
- Liu, R. H. Passive mixing in a three-dimensional serpentine microchannel. J. Microelectromechanical Syst. 9, 190-197 (2000).
- Improved Whole-Blood-Staining Device. NASA Tech Briefs. , Found at: http://www.techbriefs.com/component/content/article/10-ntb/tech-briefs/bio-medical/13574 Forthcoming.