The analysis of membrane proteins has become of increasing interest for basic and pharmaceutical research in the past 20 years. The development of novel drugs depends on the identification and detailed characterization of new targets, currently being one of the limiting factors. The fact that about 60% of all drug targets are membrane proteins1, makes the development of techniques to elucidate their function most important.
In the past, techniques for the study of electrogenic channels and transporters have been developed in multitude2-4. Non-electrogenic substrates in contrary present a more challenging task. They are however of special interest as prime drug targets, as they control the flux of solutes and nutrients across the cell membrane and function as key receptors in signaling cascades5.
Considerable effort has been put into the development of techniques to study the function of membrane transport proteins6,7. Systems using solid-supported membranes have emerged as most promising tools in this field8-10, including solid supported lipid bilayers, tethered bilayers11,12, microblack lipid membranes13,14 and native vesicle arrays15,16 to name a few. Some of them are even available as commercial setups17,18. Some examples have been published combining the ability to study single membrane proteins in a highly parallel manner14,19, a prerequisite for screening applications. However, these methods rarely bridge from basic research to the industrial environment. The difficulties often lie in the ability of the system to be automatable, the cost-intensive production and/or laborious preparation. An approach overcoming all the above mentioned obstacles is the final aim.
The technique presented here was developed to study membrane channels and transporters in vitro in a controlled environment on the single protein level20-22. Reconstitution of purified membrane proteins into LUVs is much more established than comparable approaches for GUVs23-26 or black lipid membranes27. They can directly be applied to the chip surface, where bilayer formation is taking place via a self-assembly process. The glass-bottom design of the nanoporous chip (Fig. 1) allows for air microscopy, which permits the straightforward automation of the system. In combination with a motorized stage multiple chips can be measured at the same time, with each field of view containing thousands of sealed cavities for analysis.

Figure 1. Design of multiplexed nanopore biochips. A) A silicon-on-insulator (SOI) wafer is structured by reactive-ion etching. Approximately 1,150 individual chips are fabricated from each wafer with identical properties and quality. B) Each chip comprises 250,000 individual microcavities with nano apertures. Scale bar: 200 µm. C) Each cavity is addressable via multi-spectral fluorescence read-out. An intransparent top layer blocks the fluorescent signals from the buffer reservoir, making the biochip compatible with inverted fluorescence microscopes. D) Atomic force microscopy (AFM) imaging reveals evenly arranged pore openings and surface roughness of the silicon dioxide layer of 3.6 nm (n = 40) optimal for vesicle fusion. Scale bar: 5 µm. E) Scanning electron microscopy (SEM) image shows a cross-section through the nanopore allowing access to the femtoliter cavities inside the silicon chip. This figure was reused with permission from 21. Please click here to view a larger version of this figure.
All data analysis is performed using freeware to guarantee unrestricted access for end users. Time series are analyzed using free image processing software and a custom build curve analysis software enabling batch processing and straightforward correlation of large datasets with multiple fluorescent channels and thousands of curves.
The model protein used in this protocol is the mechanosensitive channel of large conductance (MscL) channel protein derived from E. coli. It functions as a valve to release osmotic shock in nature, but was modified in such a way that rationally designed synthetic functionalities can covalently be attached to the channels constriction side. Via charge-repulsion of the covalently bound activator (MTSET) the channel is triggered to open, creating a nano-valve. Small molecules like ions, water, small proteins, but also small fluorophores can permeate through the channel. Here, the protein is used as a model to demonstrate the ability of the system to detect protein-mediated translocation.