A compact pulsed laser diode-based desktop photoacoustic tomography (PLD-PAT) system is demonstrated for high-speed dynamic in vivo imaging of small animal cortical vasculature.
A subscription to JoVE is required to view this content. Sign in or start your free trial.
Method Article
A compact pulsed laser diode-based desktop photoacoustic tomography (PLD-PAT) system is demonstrated for high-speed dynamic in vivo imaging of small animal cortical vasculature.
Photoacoustic (PA) tomography (PAT) imaging is an emerging biomedical imaging modality useful in various preclinical and clinical applications. Custom-made circular ring array-based transducers and conventional bulky Nd:YAG/OPO lasers inhibit translation of the PAT system to clinics. Ultra-compact pulsed laser diodes (PLDs) are currently being used as an alternative source of near-infrared excitation for PA imaging. High-speed dynamic in vivo imaging has been demonstrated using a compact PLD-based desktop PAT system (PLD-PAT). A visualized experimental protocol using the desktop PLD-PAT system is provided in this work for dynamic in vivo brain imaging. The protocol describes the desktop PLD-PAT system configuration, preparation of animal for brain vascular imaging, and procedure for dynamic visualization of indocyanine green (ICG) dye uptake and clearance process in rat cortical vasculature.
Photoacoustic computed tomography (PACT/PAT) is a promising non-invasive biomedical imaging modality combining rich optical contrast with high ultrasond resolution1,2,3,4,5. When a nanosecond pulsed laser deposits energy onto light absorbing chromophores present inside any biological tissue, local temperature increases leading to thermoelastic expansion and contraction of the tissue, resulting in generation of pressure waves. These pressure waves are known as ultrasound waves or photoaco....
Access restricted. Please log in or start a trial to view this content.
All animal experiments were performed according to the guidelines and regulations approved by the Institutional Animal Care and Use Committee of Nanyang Technological University, Singapore (Animal Protocol Number ARF-SBS/NIE-A0331).
1. System description
Access restricted. Please log in or start a trial to view this content.
The potentiality of the described desktop PLD-PAT system for dynamic in vivo brain imaging has been showcased in this protocol with corresponding results. High-speed imaging capability of the desktop PLD-PAT system was demonstrated by performing in vivo brain imaging of healthy female rats. PA signals were collected using eight SUTRs rotating in 360° and 45° around the rat brain at scan speeds of 4 s and 0.5 s, respectively. Figure 2A,B show brain images of a female rat (.......
Access restricted. Please log in or start a trial to view this content.
This work presents a protocol to use a desktop PLD-PAT system for conducting experiments on small animals like rats for in vivo brain imaging and dynamic fast-uptake and clearance process of contrast agents like ICG. Bulky, expensive OPO-PAT systems take several minutes (2-5 min) to acquire a single cross-sectional in vivo image. A compact, low-cost, first generation portable PLD-PAT system provides single cross-sectional in vivo images in 5 s. In contrast, a high-speed, compact, low-cost desktop PLD-PAT system renders a.......
Access restricted. Please log in or start a trial to view this content.
The authors have no relevant financial interests or potential conflicts of interest to disclose.
The research is supported by the Singapore Ministry of Health’s National Medical Research Council (NMRC/OFIRG/0005/2016: M4062012). The authors would like to thank Mr. Chow Wai Hoong Bobby for the machine shop support.
....Access restricted. Please log in or start a trial to view this content.
| Name | Company | Catalog Number | Comments |
|---|---|---|---|
| 12 V power supply | Voltcraft | PPS-11810 | To supply operating voltage for PLD |
| Acoustic reflector | Olympus | F102 | 45 degree reflector augmented to the ultrasound transducer |
| Acrylic water tank | NTU workshop | Custom-made | It is used to hold water that acts as an acoustic coupling medium between animal brain and detector |
| Anesthetic Machine | Medical plus pte ltd | Non-Rebreathing Anaesthesia machine with oxygen concentrator. | Supplies oxygen and isoflurane to animal |
| Animal distributor | In Vivos Pte Ltd, Singapore | Animal distributor that supplies small animals for research purpose | |
| Animal holder | NTU workshop | Custom-made | Used for holding animal on its abdomen |
| Breathing mask | NTU workshop | Custom-made | Used along with animal holder to supply anesthesia mixture to the animal |
| Circular Scanner | NTU workshop | Custom-made | Scanner is made out of aluminum |
| DAQ (Data acquisition) Card | Spectrum | M2i.4932-exp | 16 bit, 30 Ms/s, 8 channels, 1 Gs, PCIe |
| Data acqusition software | National Instruments Corporation,Austin,TX,USA) | NI LabVIEW 2015 SP1 (32 bit) | LabVIEW based program developed in our laboratory for controlling the stepper motor and acquring the PA singnals from the detector |
| Data processing software | Matlab (Mathworks, Natick, MA, USA) | Matlab R2015b | Matlab code developed in our laboratory for reconstructing cross-sectional PA images |
| Function generator | RIGOL | DG1022 | To change the repetition rate of the PLD. It will provide TTL signal to synchronize the DAQ with the laser excitation. |
| Low noise signal amplifier | Genetron | Custom-made using Mini-circuits, ZFL-500LN-BNC | To receive, and amplify the PA signal from SUTR. Its gain is 24 dB. |
| Optical diffuser | Thorlabs | DG-120 | Used to to make the laser beam homogeneous |
| Pulsed laser diode | Quantel, France | QD-Q1924-ILO-WATER | It is the excitation laser source with specifications of 816 nm wavelength, 3.4 mJ per pulse energy, 107 ns pulse width, 2 KHz maximum pulse repitition rate, dimensions : 13.0 x 7.6 x 5.0 cm |
| Rats | In Vivos Pte Ltd, Singapore | NTac:SD, Sprague Dawley / SD | Female, weight 100±10g, strain of rats: Sprague Dawley, age: 4-5 weeks |
| Stepper motor with gearbox | LIN Engineering (Servo Dynamics) | Motor: CO-5718L-01P-RO, Gearbox: DPL64/1; Power supply PW-100-24 | To move the detector holder in a circular geometry. Torque: 2.08 N-m, Rotor inertia: 2.6 kg-cm2 |
| Ultrasound gel | Progress/parker acquasonic gel | PA-GEL-CLEA-5000 | Clear ultrasound gel |
| Ultrasound Transducer | Olympus | V309-SU/ U8423013 | Ultrasonic sensors used for photoacoustic detection. Central freqency 5 MHz, 0.5 in |
| Variable high voltage power supply | Elektro-Automatik | EA-PS 8160-04 T | To change the laser output power |