-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Bioengineering
Automated Compression Testing of the Ocular Lens
Automated Compression Testing of the Ocular Lens
JoVE Journal
Bioengineering
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
JoVE Journal Bioengineering
Automated Compression Testing of the Ocular Lens

Automated Compression Testing of the Ocular Lens

Full Text
2,559 Views
05:19 min
April 5, 2024

DOI: 10.3791/66040-v

Debae Alzoubi1, Wade Rich1, Matthew A. Reilly1,2

1Department of Biomedical Engineering,The Ohio State University, 2Department of Ophthalmology & Visual Sciences,The Ohio State University

Summary

We present an automated method for characterizing the effective elastic modulus of an ocular lens using a compression test.

Transcript

We're trying to understand how people lose their near vision with age. We know that this isn't due in part to a change in lens stiffness, but we still don't know why the lens stiffens as we age. Current experimental methods rely on crude methods for loading the lens, such as placing microscope cover slips on the lens.

These methods are tedious and lack appropriate controls for the rate of loading. We have determined that the lens shape is the primary driver of presbyopia, and we know that the shape is primarily driven by biomechanical parameters. This protocol offers a completely objective reproducible method for measuring lens stiffness.

Automation allows us to control the rate of loading, which is a key parameter when characterizing a viscoelastic material like the lens. We now have an objective repeatable protocol for measuring lens biomechanical properties. This will allow us to rigorously characterize how the lens stiffens with age, as well as how specific proteins modify the lens biomechanical properties.

To begin, place the locally sourced pig eye on a petri dish. Remove the peripheral tissue from the pig eyes. Then use curved forceps and small dissection scissors to remove the excess flesh from the sclera until the optic nerve is visible.

Next, with a scalpel, make a shortcut at the limbus. Make another cut at the equator. Now insert a pair of micro scissors into the cut at the limbus, and use a pair of fine blunt tip forceps to lift the cornea.

Cut around the circumference of the cornea to remove it. With the blunt tip forceps, lift the iris and cut it with micro scissors to excise it. Now insert the dissection scissors into the cut at the equator and cut around the circumference to bisect the sclera.

Remove the posterior portion of the sclera. Then gently remove the vitreous humor with forceps. If required, cut the vitreous humor coronally to allow the posterior to pull away from the lens.

Use micro scissors to make a Meridiano cut through the sclera from the anterior end to the posterior end. Starting from the cut, gently stretch the zonules while pulling the lens and sclera apart, and cut between the lens and ciliary body through the zonules and around the lens circumference to isolate the lens. If desired, use forceps to puncture the capsule at the equator and peel it away to remove the capsule.

Place the lens in PBS solution, and visually inspect the lens for any damage before further testing. To begin, construct a parallel plate compression apparatus with a 50 gram force capacity loading cell enough to measure a displacement of one micrometer order. After programming the motorized stage, load the cell to perform the loading regimen.

Now fill a square box with PBS solution and place it on the compression platform. To determine the lower limit of motion and absolute gap height, lower the upper plate until it meets the lower plate. Then raise the upper plate by approximately 15 millimeters.

Now position the isolated poor sign ocular lens centrally in the box. Lower the upper plate until it is close to the upper surface of the lens. Initiate motion to move the upper plate into contact with the lens.

Commence data recording upon determination of contact, recording time, position of the upper plate relative to the lower plate and force at 500 hertz. Then apply a preconditioning loading where the lens is progressively compressed by 2.5%then 5%and 7.5%of its initial height, each occurring three times at a rate of 1%per second. Hold the position of the upper plate constant for a minute after preconditioning.

Then apply 15%compression at the rate of 1%per second before unloading at the same rate. Continue to unload until the upper plate has traveled in additional 2%of the unloaded lens thickness away from the bottom plate. To estimate the lens modulus, estimate the thickness of the lens based on the instrument's gap at the point of contact.

Alternatively, measure the thickness from a photograph taken before testing. Compute the elastic modulus using the Hertz model for compression of a sphere between parallel plates. The forced displacement curves of both encapsulated and decapsulated lenses were well-fitted by the Hertz model.

Decapsulation resulted in a significant decrease in effective elastic modulus.

Explore More Videos

Automated Compression TestingOcular LensNear Vision LossLens StiffnessPresbyopiaBiomechanical PropertiesViscoelastic MaterialLoading RateLens ShapeLens Compression TestsMotorized StageElastic ModulusForce Displacement Analysis

Related Videos

Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application

11:49

Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application

Related Videos

12.9K Views

Development of an In Vitro Ocular Platform to Test Contact Lenses

08:28

Development of an In Vitro Ocular Platform to Test Contact Lenses

Related Videos

10.9K Views

Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye

09:03

Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye

Related Videos

10.2K Views

Simulating the Mechanics of Lens Accommodation via a Manual Lens Stretcher

05:14

Simulating the Mechanics of Lens Accommodation via a Manual Lens Stretcher

Related Videos

7K Views

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography

07:44

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography

Related Videos

3.1K Views

Anterior Segment Organ Culture Platform for Tracking Open Globe Injuries and Therapeutic Performance

07:27

Anterior Segment Organ Culture Platform for Tracking Open Globe Injuries and Therapeutic Performance

Related Videos

2.1K Views

Using an Automated Hirschberg Test App to Evaluate Ocular Alignment

05:40

Using an Automated Hirschberg Test App to Evaluate Ocular Alignment

Related Videos

14.8K Views

Biological Preparation and Mechanical Technique for Determining Viscoelastic Properties of Zonular Fibers

06:39

Biological Preparation and Mechanical Technique for Determining Viscoelastic Properties of Zonular Fibers

Related Videos

2.2K Views

Sequential Application of Glass Coverslips to Assess the Compressive Stiffness of the Mouse Lens: Strain and Morphometric Analyses

07:56

Sequential Application of Glass Coverslips to Assess the Compressive Stiffness of the Mouse Lens: Strain and Morphometric Analyses

Related Videos

7.5K Views

Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients

07:06

Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients

Related Videos

2.9K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2025 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code