Two-photon imaging through a PoRTS window requires transmission through the thinned bone and the dura, which attenuates the laser light and adds optical aberrations at greater depths 8. However, despite this drawback, imaging depths up to 250 μm below the pial surface can be achieved with 900 nm excitation. Greater imaging depths may in principle be possible with longer excitation wavelengths 13. A major advantage of this method is the absence of cortical inflammation that might exist transiently in methods involving full craniotomy 14, 15. A well prepared PoRTS window should show no overt signs of angiogenesis or inflammation following implantation 8. This may be assessed in vivo during the course of the experiment by imaging vasculature structure, or by detecting morphological changes of microglia in the CX(3)CR1-GFP mouse line 8, 16, 17. Further, post hoc immunohistology should be performed to confirm the absence of astrogliosis in the superficial cortex, for example, using an antibody for glial fibrillary acidic protein 8.
The most demanding step in generating a PoRTS window is thinning the bone to 10 to 15 μm in thickness. Periodic examination of the window under a wide field fluorescence dissection microscope is also useful to gauge skull thickness during the thinning procedure. Fluorescent labels near the cortical surface should be clearly visible through the wet skull. For a more accurate measure of skull thickness, the second harmonic signal from the bone can be measured in a three-dimensional stack under two-photon microscopy (Fig. 2A to 2C). If this is done prior to application of the glue and cover glass, the bone and can be further thinned if necessary. Insufficient thinning results in poor imaging depth. Polishing will continue to thin the skull when drilling is no longer possible, and will help reduce surface irregularities and adherent bone chips. In preliminary studies, we have found that polishing improves imaging depth weeks after the initial implantation. However, a rigorous analysis on the benefit of polishing has not been performed.
The application of cyanoacrylate glue and cover glass atop the bone is a critical step to reduce light scattering and allow for deeper imaging. Due to the drilling process, the surface of the bone will be irregular, even after polishing, and therefore light scattering. The application of cyanoacrylate glue fills in these irregularities and the overlying cover glass leaves a non-scattering smooth surface. Importantly, the refractive indices for the glue and cover glass, which are 1.45 and 1.52 according to manufacturer specifications, are closely indexed matched to that of bone at 1.55 18. This is an improvement over having air or water above the thinned skull, which have refractive indices of 1.00 and 1.33. Critically, the cyanoacrylate glue further helps to impede bone re-growth. This enables longitudinal imaging for up to three months, without the need for additional maintenance after the initial surgery.
A second cause of poor imaging depth is damage to pial vessels leading to hemorrhaging or edema. Vibrations from the drill should be minimized. In a small proportion of cases, bleeding within the dura will be unavoidable. This is because the vasculature of the dura mater is continuous with the vascular plexus of the skull, which is disturbed during the thinning procedure. Preparations with any sign of sub-dural bleeding should be discarded as dural thickening and angiogenesis will ensue. The success rate of the PoRTS window can be as high as 80% with practice.
For some experiments, it may be necessary to inject dyes/viruses or insert electrodes into the tissue beneath the PoRTS window. It is possible to generate a small hole adjacent to the window, through which pipettes or electrodes can be introduced using a stereotaxic arm or Sutter manipulator 19. This hole can be resealed with bone wax if the animal is to be imaged again in future sessions. However, the introduction of electrodes can of course lead to inflammation in the cortex and acute pathology such as spreading depression.
The PoRTS window should be well suited for any imaging modality requiring optical access to the brain. This includes surface imaging techniques such as intrinsic optical imaging 20 and laser speckle imaging 21, or optical sectioning techniques such as confocal 22 or two-photon microscopy 23. Further, a PoRTS preparation should improve resolution in wide field transcranial imaging techniques such as optical coherence tomography 24 and photoacoustic microscopy 25.
Finally, the PoRTS window is suitable for imaging of awake animals as the cover glass adds rigidity to the window 4. The head mount is further stabilized by the introduction of two self-tapping #000 screws to the contralateral hemisphere prior to application of the dental cement (Fig. 1L). Habituation to head-fixation is important to reduced animal movement during imaging. A new animal can be gradually accustomed to head-restraint over a period of 3 to 7 days prior to imaging, starting with 15 min sessions and working up to several hours.