Substernal thyroid goiter (STG) is a slow growing tumor, eventually causing symptoms in 70-80% of cases. As per literature review, between 2.5-22.6% of STG can have malignant transformation2. Compression of the trachea, esophagus, recurrent laryngeal nerve, and superior vena cava often causes symptoms like dyspnea, stridor, cough, dysphagia, dysphonia, vocal cord paralysis, Horner’s syndrome, superior vena cava syndrome, and cerebral edema. Occasional cases of overt hyperthyroidism have also been reported. A retrospective study by Shin et al. reported a positive correlation between thyroid size and presence of shortness of breath, globus sensation, and symptoms of hyperthyroidism3. This study, however, did not find a correlation between goiter size and presence of dysphagia, local discomfort, changes in voice, hemoptysis, or symptoms of hypothyroidism. Both substernal and cervical goiters carry similar malignancy risk. However, the retrosternal location makes diagnostic biopsy and treatment of STG very challenging. Most cases eventually require surgical removal using mediastinoscopy or sternotomy.
Endobronchial ultrasound (EBUS) was first described in 1992 by Hurter and Hanrath4. Over the years, EBUS-TBNA has become the procedure of choice for diagnosis and staging of non-small cell lung cancer. The reported sensitivity, specificity, and positive predictive value of EBUS-TBNA for mediastinal and hilar lymphadenopathy is 94%, 100%, and 100% respectively, with a low complication rate making it very safe, effective and superior to conventional TBNA5. However, both conventional and EBUS-guided TBNA were found to have statistically similar results for subcarinal lymph nodes6.
Two types of EBUS probes have been developed so far – the radial probe (RP-EBUS) and the curvilinear probe (CP-EBUS). RP-EBUS was the first one to become commercially available in 1999. It has a thin ultrasound probe inside a water-inflatable balloon tip. The probe rotates 360° at an angle perpendicular to the axis of insertion. The inflated balloon provides a circular contact for the probe, enabling it to obtain 360° view around the airways. It is used for evaluation of the central airways, assessment of airway invasion and obtaining biopsy of peripherally located lesions7,8. After the lesion is localized, radial probe must be taken out of the guide sheath in the bronchoscope’s working channel to make way for the biopsy tool. Hence, a real-time ultrasound guided biopsy cannot be performed. Three different radial probes are currently available - 20-MHz and 30-MHz miniature probes, and the 20-MHz ultra-miniature probe. The miniature probes can be inserted through the 2.8 mm working channel of a bronchoscope and reach sub-segmental airways; the higher frequency probe provides better image resolution9. With an outer diameter of 1.4 mm, the ultra-miniature probe fits into the 2 mm working channel of the smaller bronchoscope and reaches more peripheral lesions.
CP-EBUS was introduced in 2005. It is a 7.5 MHz convex probe inside a saline-inflatable balloon at the tip of the bronchoscope (Figure 1). The outer diameter of the bronchoscope tube is 6.3 mm, and of the tip is 6.9 mm. The inner diameter of the working channel is 2.2 mm. The scope looks at a 35° forward oblique angle, with an angle of view of 80° (Figure 2). The convex probe itself generates a 50° image, and scans parallel to the insertion axis. Ultrasound images can be obtained by either placing the probe directly over the bronchial wall using forward flexion, or by additionally inflating the balloon with saline. Water is a better conductor than air of ultrasound waves, and improves image quality. Vascular structures can be differentiated from tissues using the color Doppler mode scan. Biopsy is performed using a dedicated 22 or 21 G TBNA needle with an echogenic-dimpled tip (Figure 3), which comes out at an angle of 20° to the long axis of the bronchoscope. The needle has a maximum extruding stroke of 40 mm, with a safety mechanism that stops it at 20 mm to prevent excessive protrusion. The internal wire of the needle minimizes sample contamination while the needle passes through the bronchial wall. It is also used to clean up the needle after it has passed through the bronchial wall and into the targeted lesion. The optimal number of aspiration “passes” is reported to be 3-7 for a satisfactory sample, but the highest yield is from the first pass10,11. The images are processed in a dedicated ultrasound processor. Both ultrasound and white-light bronchoscopy images are simultaneously visible on the monitor, allowing for easy navigation to the site of the suspected lesion. CP-EBUS has the ability to perform real-time TBNA with direct ultrasound guidance under moderate sedation or general anesthesia. The procedure can be performed in an outpatient setting, eliminating surgery-related morbidity and need for inpatient admission.
The use of EBUS-TBNA for diagnosis of substernal thyroid is new, and has been reported in only a few case reports12-18. Based on the review of the current literature, this paper seeks to elaborate on the procedural requirements and propose EBUS-TBNA as a modality for biopsy of substernal thyroid gland. Please note that the above equipment description is more specific to Olympus Inc. There are other commercially available products as well, and minor variations do exist.