This protocol is for the performance of one-anastomosis gastric bypass (OAGB) on rat. The operator performs a long and tubular-stapled gastric pouch followed by hand-sewn anastomosis. For this model, the operator reproduces the same ratio between biliopancreatic and common limb in humans; therefore, the biliopancreatic limb measures 35 cm.