Summary

Totalmente automatizada de dispositivos de microfluidos para centrífuga Ultrasensible detección de proteínas a partir de sangre entera

Published: April 16, 2016
doi:

Summary

This protocol demonstrates how to achieve femto molar detection sensitivity of proteins in 10 µL of whole blood within 30 min. This can be achieved by using electrospun nanofibrous mats integrated in a lab-on-a-disc, which offers high surface area as well as effective mixing and washing for enhanced signal-to-noise ratio.

Abstract

Enzyme-linked immunosorbent assay (ELISA) is a promising method to detect small amount of proteins in biological samples. The devices providing a platform for reduced sample volume and assay time as well as full automation are required for potential use in point-of-care-diagnostics. Recently, we have demonstrated ultrasensitive detection of serum proteins, C-reactive protein (CRP) and cardiac troponin I (cTnI), utilizing a lab-on-a-disc composed of TiO2 nanofibrous (NF) mats. It showed a large dynamic range with femto molar (fM) detection sensitivity, from a small volume of whole blood in 30 min. The device consists of several components for blood separation, metering, mixing, and washing that are automated for improved sensitivity from low sample volumes. Here, in the video demonstration, we show the experimental protocols and know-how for the fabrication of NFs as well as the disc, their integration and the operation in the following order: processes for preparing TiO2 NF mat; transfer-printing of TiO2 NF mat onto the disc; surface modification for immune-reactions, disc assembly and operation; on-disc detection and representative results for immunoassay. Use of this device enables multiplexed analysis with minimal consumption of samples and reagents. Given the advantages, the device should find use in a wide variety of applications, and prove beneficial in facilitating the analysis of low abundant proteins.

Introduction

Varias plataformas para el diagnóstico de la enfermedad se han desarrollado sobre la base de materiales a nanoescala 1,2 tales como nanocables, 3 nanopartículas, nanotubos de 4, 5 y nanofibras (NFS) 6-8. Estos nanomateriales ofrecen excelentes perspectivas en el diseño de nuevas tecnologías para bioensayos altamente sensibles debido a sus propiedades físico-químicas únicas. Por ejemplo, las nanofibras de óxido de zinc mesoporoso se han utilizado para la detección sensible femto-molar de biomarcadores de cáncer de mama. 9 Recientemente, los nanomateriales a base de dióxido de titanio (TiO 2) han sido exploradas para aplicaciones bioanalíticos 10 teniendo en cuenta su estabilidad química, 11 desnaturalización de la proteína insignificante , 12 y biocompatibilidad. 13 Además, los grupos hidroxilo en la superficie de TiO 2 facilitar la modificación química y la unión covalente de biomoléculas. 14,15 modelado TiO 2 thin películas 16 o TiO 2 nanotubos 17 se han utilizado para mejorar la sensibilidad de detección de una proteína diana por aumento de la superficie; sin embargo, el proceso de fabricación es bastante complejo y requiere un equipo caro. Por otra parte, las federaciones nacionales electrospun están recibiendo atención debido a su gran área de superficie, así como proceso sencillo y fabricación de bajo costo; 18,19 sin embargo, la característica frágiles o suelto de la electrospun TiO2 NF tapete hace que sea difícil de manejar y integrar con los dispositivos de microfluidos. 6,20 por lo tanto, las esteras de TiO2 NF rara vez se utilizan en aplicaciones de bioanálisis, particularmente aquellos que requieren condiciones de lavado agresivos.

En este estudio, para superar estas limitaciones, hemos desarrollado una nueva tecnología para la transferencia de la electrospun NF esteras sobre la superficie de cualquier sustrato diana mediante la utilización de una capa de adhesivo de polidimetilsiloxano delgada (PDMS). Furthermore, hemos demostrado con éxito la integración de electrospun TiO 2 NF esteras en un dispositivo de microfluidos centrífuga de policarbonato (PC). El uso de este dispositivo, una detección de alta sensibilidad, totalmente automatizado e integrado de la proteína C-reactiva (CRP), así como la troponina I cardíaca (cTnI) se logró en 30 min a partir de solamente 10 l de sangre entera. 21 Debido a la combinación ventajas de las propiedades de los NF y la plataforma centrífuga, el ensayo exhibieron una amplia gama dinámica de seis órdenes de magnitud de 1 pg / ml (~ 8 fM) a 100 ng / ml (~ 0,8 pM) con un límite inferior de detección de 0,8 pg / ml (~ 6 fM) para la PCR y un rango dinámico de 10 pg / ml (~ 0,4 pM) a 100 ng / ml (~ 4 nM) con un límite de detección de 37 pg / ml (~ 1,5 pM) de cTnI. Estos límites de detección son ~ 300 y ~ 20 veces menor en comparación con sus correspondientes resultados de ELISA convencionales. Esta técnica se podría aplicar para la detección de cualquier proteína objetivo, con los anticuerpos apropiados. En general, este dispositivo de coULD contribuyen en gran medida en el diagnóstico in vitro y ensayos bioquímicos ya que puede detectar cantidades raras de proteínas diana con gran sensibilidad incluso de cantidades muy pequeñas de muestras biológicas, por ejemplo, 10 l de sangre entera. A pesar de que sólo demostró la detección de proteínas de suero usando ELISA en este estudio, la tecnología de transferencia e integración de electrospun NFS con dispositivos de microfluidos podría aplicarse más ampliamente en otras reacciones bioquímicas que requieren una gran área superficial para la alta sensibilidad de detección.

Protocol

NOTA: Se extrajo sangre de individuos sanos y se recogió en un tubo de recogida de sangre. escrito el consentimiento informado se obtuvo de todos los voluntarios. 1. La fabricación de TiO2 NF Mat Preparación de solución de precursor 22 Disolver 1,5 g de tetraisopropóxido de titanio (TTIP) en una mezcla de etanol (99,9%, 3 ml) y ácido acético glacial (3 ml) y se mezcla la solución a temperatura ambiente (25 ?…

Representative Results

El uso de este protocolo, un dispositivo de microfluidos centrífuga totalmente automatizado para la detección de proteínas de la sangre total se preparó con una alta sensibilidad. Las esteras de TiO2 NF fueron preparados por los procesos de electrospinning y calcinación. Con el fin de fabricar el FNs de diámetro deseado, la morfología y espesor, electrospinning condiciones tales como velocidad de flujo, tensión, y el tiempo de hilado fueron optimizados. Cuando las cond…

Discussion

El ensayo en TiO 2 NF disco integrado es una técnica rápida, de bajo costo y conveniente para la detección ultrasensible de proteínas de baja abundancia presentes en muy bajo volumen de sangre. Esta técnica tiene la ventaja de usar pequeños volúmenes de muestra (10 l) y es susceptible para el análisis de múltiples muestras simultáneamente. Esto proporciona un gran potencial como un dispositivo de multiplexación inmunoensayo. El dispositivo tiene la ventaja de que no requiere etapas de pretratamient…

Disclosures

The authors have nothing to disclose.

Acknowledgements

Este trabajo fue apoyado por la Fundación Nacional de Investigación de Corea (NRF) subvenciones (2013R1A2A2A05004314, 2012R1A1A2043747), una subvención de la tecnología de la salud R coreana + D Proyecto, Ministerio de Salud y Bienestar Social (A121994) y el SII-R020-D1 financiado por el Gobierno de Corea.

Materials

Si wafer LG SILTRON Polished Wafer, test grade Dia. (mm) = 150, orientation = <100>, dopant = boron, RES(Ohm-cm) = 1 – 30, thickness (μm) = 650 – 700
Polycarbonate (PC)  Daedong Plastic PCS#6900 Thickness (mm) = 1 and 5 
Titanium tetraisopropoxide, 98%, Sigma-Aldrich 205273
Polyvinylpyrrolidone, Mw = 1,300,000 Sigma-Aldrich 437190
Acetic acid Sigma-Aldrich 320099
Anhydrous ethanol Sigma-Aldrich 459836
Tridecafluoro-1,1,2,2-tetrahydrooctyl)-1-trichlorosilane Sigma-Aldrich 448931
PDMS and curing agent Dow Corning SYLGARD 184
GPDES Gelest Inc SIG5832.0 
Ethanol J T Baker
FE-SEM FEI Nova NanoSEM
X-ray photoelectron spectroscopy ThermoFisher K-alpha
3D modeling machine M&I CNC Lab, Korea CNC milling machine
Wax-dispensing machine Hanra Precision Eng. Co. Ltd., Korea Customized
Double-sided adhesive tape FLEXcon, USA DFM 200 clear 150 POLY H-9 V-95
Cutting plotter Graphtec Corporation, Japan Graphtec CE3000-60 MK2
Spin coater MIDAS SPIN-3000D
Furnace (calcination) R. D. WEBB COMPANY WEBB 99
Rheometer (Tack test) Thermo Scientific Haake MARS III – ORM Package
Oxygen plasma system FEMTO CUTE
Monoclonal mouse antihuman hsCRP Hytest Ltd., Finland 4C28 (clone # C5)
Monoclonal mouse anti-cTnI Hytest Ltd., Finland 4T21 (clone # 19C7)
HRP conjugated goat polyclonal anti-hsCRP Abcam plc., MA ab19175
HRP conjugated mouse monoclonal anti-cTnI Abcam plc., MA ab24460 (clone # 16A11)
hsCRP Abcam plc., MA ab111647
cTnI Fitzgerald, MA 30-AT43
Bovine Albumin Sigma-Aldrich A7906
PBS Amresco Inc E404
Blood collection tubes BD vacutainer 367844 K2 EDTA 7.2 mg plus blood
collection tubes
SuperSignal ELISA femto Invitrogen 37074
Modular multilabel plate reader Perkin Elmer Envision 2104
Disc operating machine Hanra Precision Eng. Co. Ltd., Korea Customized
Photomultiplier tube (PMT) Hamamatsu Photonics H1189-210
AutoCAD AutoDesk Version 2012 Design software
SolidWorks 3D CAD software  SOLIDWORKS Corp. Version 2013 3D Design software,
Edgecam Vero software version 2009.01.06928 Code generating software
DeskCNC Carken Co. version 2.0.2.18 CNC milling machine software

References

  1. Zhang, Y., et al. Nanomaterials for Ultrasensitive Protein Detection. Adv. Mater. 25 (28), 3802-3819 (2013).
  2. Hu, W., Li, C. M. Nanomaterial-based advanced immunoassays. Wiley Interdiscip. Rev. Nanomed. Nanobiotechnol. 3 (2), 119-133 (2011).
  3. Yang-Kyu, C., Chang-Hoon, K. Silicon Nanowire Biosensor for Cancer Markers. Biosensors and Cancer. , 164-183 (2012).
  4. Baltazar, R., Vistas, C. R., Ferreira, G. M. Biosensing Applications Using Nanoparticles. Nanocomposite Particles for Bio-Applications. , 265-282 (2011).
  5. Roy, P., Berger, S., Schmuki, P. TiO2 Nanotubes: Synthesis and Applications. Angew. Chem. Int. Ed. 50 (13), 2904-2939 (2011).
  6. Yang, D., et al. Electrospun Nanofibrous Membranes: A Novel Solid Substrate for Microfluidic Immunoassays for HIV. Adv. Mater. 20 (24), 4770-4775 (2008).
  7. Chantasirichot, S., Ishihara, K. Electrospun phospholipid polymer substrate for enhanced performance in immunoassay system. Biosens. Bioelectron. 38 (1), 209-214 (2012).
  8. Zhang, N., et al. Electrospun TiO2 Nanofiber-Based Cell Capture Assay for Detecting Circulating Tumor Cells from Colorectal and Gastric Cancer Patients. Adv. Mater. 24 (20), 2756-2760 (2012).
  9. Ali, M. A., Mondal, K., Singh, C., Dhar Malhotra, B., Sharma, A. Anti-epidermal growth factor receptor conjugated mesoporous zinc oxide nanofibers for breast cancer diagnostics. Nanoscale. 7 (16), 7234-7245 (2015).
  10. Mondal, K., Ali, M. A., Agrawal, V. V., Malhotra, B. D., Sharma, A. Highly Sensitive Biofunctionalized Mesoporous Electrospun TiO2 Nanofiber Based Interface for Biosensing. ACS Appl. Mater. Interfaces. 6 (4), 2516-2527 (2014).
  11. Tu, W., Dong, Y., Lei, J., Ju, H. Low-Potential Photoelectrochemical Biosensing Using Porphyrin-Functionalized TiO2 Nanoparticles. Anal. Chem. 82 (20), 8711-8716 (2010).
  12. Liu, S., Chen, A. Coadsorption of Horseradish Peroxidase with Thionine on TiO2 Nanotubes for Biosensing. Langmuir. 21 (18), 8409-8413 (2005).
  13. Portan, D. V., Kroustalli, A. A., Deligianni, D. D., Papanicolaou, G. C. On the biocompatibility between TiO2 nanotubes layer and human osteoblasts. J.Biomed.Mater.Res. Part A. 100 (10), 2546-2553 (2012).
  14. Dettin, M., et al. Covalent surface modification of titanium oxide with different adhesive peptides: Surface characterization and osteoblast-like cell adhesion. J. Biomed. Mater. Res. Part A. 90 (1), 35-45 (2009).
  15. Kim, W. -. J., et al. Enhanced Protein Immobilization Efficiency on a TiO2 Surface Modified with a Hydroxyl Functional Group. Langmuir. 25 (19), 11692-11697 (2009).
  16. Son, K. J., Ahn, S. H., Kim, J. H., Koh, W. -. G. Graft Copolymer-Templated Mesoporous TiO2 Films Micropatterned with Poly(ethylene glycol) Hydrogel: Novel Platform for Highly Sensitive Protein Microarrays. ACS Appl. Mater. Interfaces. 3 (2), 573-581 (2011).
  17. Kar, P., Pandey, A., Greer, J. J., Shankar, K. Ultrahigh sensitivity assays for human cardiac troponin I using TiO2 nanotube arrays. Lab Chip. 12 (4), 821-828 (2012).
  18. Agarwal, S., Wendorff, J. H., Greiner, A. Use of electrospinning technique for biomedical applications. Polymer. 49 (26), 5603-5621 (2008).
  19. Ding, B., Wang, M., Wang, X., Yu, J., Sun, G. Electrospun nanomaterials for ultrasensitive sensors. Mater. Today. 13 (11), 16-27 (2010).
  20. Liu, Y., Yang, D., Yu, T., Jiang, X. Incorporation of electrospun nanofibrous PVDF membranes into a microfluidic chip assembled by PDMS and scotch tape for immunoassays. ELECTROPHORESIS. 30 (18), 3269-3275 (2009).
  21. Lee, W. S., Sunkara, V., Han, J. -. R., Park, Y. -. S., Cho, Y. -. K. Electrospun TiO2 nanofiber integrated lab-on-a-disc for ultrasensitive protein detection from whole blood. Lab Chip. 15 (2), 478-485 (2015).
  22. Li, D., Xia, Y. Fabrication of Titania Nanofibers by Electrospinning. Nano Lett. 3 (4), 555-560 (2003).
  23. Lombard, M. . SolidWorks 2013 BIBLE. , (2013).
  24. Tickoo, S. . EdgeCAM 11.0 for Manufacturers. , (2007).
  25. Zhu, R., et al. Improved adhesion of interconnected TiO2 nanofiber network on conductive substrate and its application in polymer photovoltaic devices. Appl. Phys. Lett. 93 (1), 013102 (2008).
  26. Song, M. Y., Ahn, Y. R., Jo, S. M., Kim, D. Y., Ahn, J. -. P. TiO2 single-crystalline nanorod electrode for quasi-solid-state dye-sensitized solar cells. Appl. Phys. Lett. 87 (11), 113113 (2005).
  27. Katsuhiro, O., et al. Electrospinning processed nanofibrous TiO2 membranes for photovoltaic applications. Nanotechnology. 17 (4), 1026-1031 (2006).

Play Video

Cite This Article
Park, Y., Sunkara, V., Kim, Y., Lee, W. S., Han, J., Cho, Y. Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood. J. Vis. Exp. (110), e54143, doi:10.3791/54143 (2016).

View Video