$$\rightleftharpoonup{xx}$$
$$\longleftharp{xx}$$,
$$\longrightharp{xx}$$,
Thermally Reversible Ionogels
Physical gelation is a process which allows the construction of structures of self-assembled gelator molecules in presence of the solvent molecules. Due to non-covalent nature of the interactions responsible for this phenomenon (e.g. hydrogen bonding, van der Waals interactions, dispersion forces, electrostatic forces, π-π stacking, etc.), these systems are thermally reversible. This thermal reversibility, together with the very low concentration of the gelator and the wide variety of the systems that can be created, are some of the main advantages of physical gels over chemical ones. Thanks to the unique properties of the physical gel state, the ionogels are characterized with desirable features like easy recycling, long cycle life, enhanced physical properties (e.g. ionic conductivity), ease of production, and lowering of the production costs. Taking into the account the above advantages of physical gels (which already have a wide range of different applications1,2,3,4), these were thought to be used as an alternative way for electrolyte solidification and obtaining of ionogels5,6,7,8. However, the classical conductometry was not sensitive and accurate enough to follow such dynamically changing systems. Therefore,it could not detect the phase transitions and enhanced dynamics of ions in the gel matrix9. The reason for this insensitivity was the time needed for the temperature stabilization, during which dynamic changes of the sample properties were underway before the measurement was started. Furthermore, the number of measured temperatures was limited in order, not to significantly extend the experimental time. Therefore, to fully and accurately characterize the ionogels, a new method was needed, which would be able to follow the dynamic changes of properties as a function of temperature, and record data continuously in real time. The way the gelation process is conducted determines the properties of the created ionogel. The intermolecular non-covalent interactions are defined during the cooling stage; by changing the gelation temperature and cooling rates, one can strongly influence those interactions. Therefore, it was extremely important to measure the system during cooling when the gelation takes place. With the classical approach, this was impossible due to temperature stabilization time for the measurement, and the fast cooling rates required for successful gelation. However, with the thermal scanning conductometry method this task is very simple, delivers accurate and reproducible results, and allows the investigation of the influence of different kinetics of thermal changes applied to the sample on sample properties10. As a result, the ionogels with targeted properties can be studied and manufactured at the same time.
Thermal Scanning Conductometry (TSC)
The thermal scanning conductometry is supposed to deliver a reproducible, accurate, and fast responding experimental method for the conductivity measurement of dynamically changing and thermally reversible systems, like ionogels based on low molecular weight gelators. However, it can be also used with electrolytes, ionic liquids, and any other conducting sample that can be placed in the measuring cell and has conductivity in the measuring range of the sensor. Additionally, besides the research application, the method was successfully used to manufacture ionogels with targeted properties like microstructure, optical appearance or thermal stability, and phase transition temperature in an accurate and easy way. Depending on the kinetics and history of thermal treating with use of the TSC method, we gain full control over some basic properties of physical gel systems. Additionally the chamber have been equipped in a video camera to inspect the sample state and record the changes of the sample especially during gelation and dissolution processes. An additional advantage of the TSC method is its simplicity, as the system can be built from a standard conductometer, a programmable temperature controller, the gaseous nitrogen line for the heating/cooling medium, the refrigerator, measuring chamber, and a PC, which can be found in most laboratories.
The TSC Experimental Site
The thermal scanning conductometry experimental setup can be built in almost every laboratory with relatively low costs. In return, one obtains an accurate, reproducible, and fast method for measuring liquid and semisolid conductive samples at different external conditions. A detailed scheme of the TSC experimental setup built in our laboratory is given in Figure 1.

Figure 1: Block diagram of the measurement site. The components consisting on working experimental setup for thermal scanning conductometry method. Please click here to view a larger version of this figure.
For the temperature change, a homemade temperature controller was used, but any kind of programmable temperature controller, which can change the temperature linearly with a defined change rate, can be used. For thermal isolation, a special chamber has been built. The purpose of using an isolation chamber is to minimize temperature horizontal gradients in the sample, and to assure fast cooling rates. The chamber consists of a glass cylinder with a 40-mm inner diameter and 300 mm length. At the bottom side, where the heater with gaseous nitrogen inlets are located, the end of the inlet is equipped with a diffusor to evenly spread the hot or cold gas. This is also the place where the temperature sensor PT100 of the variable temperature controller (VTC) is located. The temperature of the sample is recorded independently by the temperature sensor located in the conductivity sensor. Additionally, the chamber have been equipped in a video camera to inspect the sample state and record the changes of the sample especially during gelation and dissolution processes. The gaseous nitrogen obtained from evaporation of liquid nitrogen in the 250 L high pressure tank is used as a heating and cooling medium. The working pressure in the nitrogen line is set to 6 bars, and reduced to 2 bars at the measuring site. Such settings allow the obtainment of flow rates between 4 and 28 L/min without any disturbances, which allows a cooling rate of 10 °C/min. To lower the initial temperature of the nitrogen gas, the external refrigerator has been used, and the decreased temperature was 10 °C. This allows the obtainment of good linearity of the temperature change, starting from room temperature. During fast cooling, the temperature of the nitrogen gas is decreased to -15 °C to assist high cooling rates. It is necessary to use gaseous nitrogen, and not even dry air, to avoid icing the refrigerator because of low temperatures.
The samples were inserted into a vial of 9 mm inner diameter and length of 58 mm, made of polypropylene, and equipped with a screw cap, which has a rubber ring for tight closing. The vials can be used up to 120 °C. (see Figure 2).

Figure 2: The picture of a polypropylene vial and its mounting on the conductivity sensor. (1) the polypropylene vial, (2) the screw cap with rubber ring, 2a - the screw cap mounted on the conductivity sensor, (3) the vial with mounted conductivity sensor, the screw cap secured with Teflon tape. Please click here to view a larger version of this figure.