The current article describes performing an intravital imaging approach to observe mechanically induced calcium signaling of embedded osteocytes in vivo in real-time in response to tissue-level mechanical loading of the mouse third metatarsal.
Method Article
Access restricted. Please log in or start a trial to view this content.
Access restricted. Please log in or start a trial to view this content.
Access restricted. Please log in or start a trial to view this content.
Access restricted. Please log in or start a trial to view this content.
| Name | Company | Catalog Number | Comments |
|---|---|---|---|
| #3 Handle scalpel | Electron Microscopy Sciences | 72040-03 | Surgical supplies |
| 20x Water immersion objective | Olympus | XLUMPLFLN20XW | This is a 20x objective, but 40x can also be used for this protocol. We recommend water immersions because it needs to be dipped in the bath during imaging, so open-air objective may cause abberrations |
| A.M. Bickford Omnicon F/AIR | AM Bickford | 80120 | A sensible answer to anesthesia gas problems in the operating room, the F/AIR anesthesia gas filter was specifically designed to remove waste anesthesia gases such as Isoflurane, Halothane, Enflurane, etc. from the operating room environment. |
| A.M. Bickford Omnicon F/AIR Kit | AM Bickford | 80000 | An entire kit with tube and adaptors to connect F/AIR to setup |
| B6J.Cg-Gt(ROSA)26Sortm95.1(CAG-GCaMP6f)Hze/MwarJ | The Jackson Laboratory | 28865 | GCaMP6f Mice for cross-breeding with Dmp1-Cre mice |
| B6N.FVB-Tg(Dmp1-cre)1Jqfe/BwdJ | The Jackson Laboratory | 23047 | Dmp1-Cre Mice for cross-breeding with GCaMP6f mice |
| Compression load cell | FUTEK Advanced Sensor Technology, Inc. | 905898 | LCM100 , 1000 g , Sub-miniature tension & compression load cell (Miniature/Inline Threaded) , RoHS lead free, Material - 17-4 PH S.S. , M3x0.5-thread , 34 Awg 4 conductor braided polyester cable , 5 ft Long |
| Corning 500 mL DPBS (Dulbecco's phosphate buffered saline), 1x [+] calcium, magnesium | VWR International | 21-030-CV | Ionically balanced bath that contains calcium submerges the metatarsal during imaging |
| Dental pick tool | Electron Microscopy Sciences | Surgical supplies | |
| Ethyl alcohol pure 200 proof ACS reagent >99.5% | Sigma Aldrich | SIAL-459844-500ML | Sterilization purposes |
| Fulcrum pin | Fathom | N/A | Fabricated by direct 3D laser sintering of stainless steel (PH1 alloy) from 3D SolidWorks STL files. Original vendor was GPI Prototype & Manufacturing Services, Inc, now acquired by FATHOM, specifications are provided in the previously published document |
| High resolution and speed USB220 output kit | FUTEK Advanced Sensor Technology, Inc. | 717435 | Used to connect load cell to laptop |
| ImageJ 1.53t with Java 1.8.0_172 (for Windows 64-bit) | NIH | N/A | Install here https://imagej.nih.gov/ij/ |
| Isoflurane | Piramal Critical Care | 66794-013-25 | 100% inhalation vapour liquid |
| Loading bracket | Fathom | N/A | Fabricated by direct 3D laser sintering of stainless steel (PH1 alloy) from 3D SolidWorks STL files. Original vendor was GPI Prototype & Manufacturing Services, Inc, now acquired by FATHOM, specifications are provided in the previously published document |
| MATLAB R2019a | MathWorks | For running the loading device | |
| Matrx VIP 3000 vaporizer well fill isoflurane | Butler Schein Animal Health | 14309 | Vaporizer for anesthetic |
| Nonin pulse oximeter Model 2500A Vet | 2500A Vet | ||
| Piezo servo controller | PI-USA | E-625 | Electronic component recommended by the company to be used with the actuator |
| PiezoMove high-stiffness linear piezo actuator | PI-USA | P-602.5SL | Actuator for the loading device |
| Scalpel blades, No. 10 for handle No. 3, pack of 100 | Electron Microscopy Sciences | 72044-10 | Surgical supplies |
| Stainless steel tweezers with sharp, fine tips. Length: 120 mm | Electron Microscopy Sciences | 78326-42 | Surgical supplies |
| Thorlabs Bergamo multiphoton microscope | ThorLabs | N/A | This is only the imaging system and does not have the laser included, although ThorLabs has laser options if desired |
| Titanium-Saphire Chameleon Discovery NX with Total Power Control (TPC) | Coherent | N/A | This system technically has two lasers, both a tunable and a fixed laser. However, for the protocol, only the tunable is needed. |
| Vannas spring scissors - 4 mm cutting edge | Fine Science Tools | 15018-10 | Surgical supplies |
| Water bath | Fathom | N/A | Fabricated by direct 3D laser sintering of stainless steel (PH1 alloy) from 3D SolidWorks STL files. Original vendor was GPI Prototype & Manufacturing Services, Inc, now acquired by FATHOM, specifications are provided in the previously published document |
Access restricted. Please log in or start a trial to view this content.
Request permission to reuse the text or figures of this JoVE article
Request Permission