Bioengineering

Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies

Published: March 17, 2023 doi: 10.3791/65209

Summary

The protocol summarizes the best practices to minimize microbial bioburden in a cleanroom environment and includes strategies such as environmental monitoring, process monitoring, and product sterility testing. It is relevant for manufacturing and testing facilities that are required to meet current good tissue practice standards and current good manufacturing practice standards.

Abstract

A well-validated and holistic program that incorporates robust gowning, cleaning, environmental monitoring, and personnel monitoring measures is critical for minimizing the microbial bioburden in cellular therapy manufacturing suites and the corresponding testing laboratories to ensure that the facilities are operating in a state of control. Ensuring product safety via quality control measures, such as sterility testing, is a regulatory requirement for both minimally manipulated (section 361) and more than minimally manipulated (section 351) human cells, tissues, and cellular and tissue-based products (HCT/Ps). In this video, we provide a stepwise guide for how to develop and incorporate the best aseptic practices for operating in a cleanroom environment, including gowning, cleaning, staging of materials, environmental monitoring, process monitoring, and product sterility testing using direct inoculation, provided by the United States Pharmacopeia (USP<71>) and the National Institutes of Health (NIH) Alternative Sterility Testing Method. This protocol is intended as a reference guide for establishments expected to meet current good tissue practices (cGTP) and current good manufacturing practices (cGMP).

Introduction

Implementing a strong microbial monitoring program through environmental monitoring (EM), process monitoring, and product sterility testing is a regulatory requirement for current good tissue practices (cGTP) and current good manufacturing practices (cGMP) in cellular therapy laboratories1. Additionally, the United States Food and Drug Administration (FDA) expects that the laboratory performing the quality control (QC) testing of the product should also employ facilities and controls comparable to those used for aseptic filling operations2.

This protocol has four main sections: 1) Aseptic practices, including personnel gowning, cleaning, and staging of materials; 2) EM, including viable air and surface cultures and non-viable particle air monitoring; 3) process monitoring, including settling plates and gloved fingertip sampling; and 4) product sterility testing via the compendial United States Pharmacopeia (USP) <71> method3 or the NIH Alternative Sterility Testing Method4. When used together, these measures can be an effective method for ensuring that a facility remains in a state of control.

The techniques described here are not novel; however, current standards from regulators and professional organizations lack detail, which has led to an absence of microbial monitoring or the implementation of non-standardized practices, particularly in academic centers where on-site manufacturing and product sterility testing are emerging at a rapid rate1,5,6. This protocol can be used as a guide to create a microbial monitoring and control program that meets regulatory requirements when used in conjunction with end-user validation and risk assessments.

Subscription Required. Please recommend JoVE to your librarian.

Protocol

1. Aseptic practices

  1. Personnel gowning for a cleanroom space
    NOTE: This procedure is based on initial gowning in an unclassified space, followed by entry into an International Organization for Standardization (ISO) 8 area and then an ISO7 area. This procedure is relevant for laboratories attempting to convert existing space into a cleanroom function. Ideally, all initial gowning would occur in an ISO8 classified space (not in an unclassified space).
    1. Secure loose hair. Wash hands, and change into scrubs (long-sleeve scrub tops and full-length scrub pants are preferable). Gather and change into cleanroom shoes with shoe covers on.
    2. Sanitize the hands using an alcohol-based hand sanitizer initially and then again between each of the following steps: donning non-sterile gloves and then a beard cover (for any amount of visible facial hair), if applicable. Don a non-sterile bouffant, and cover the forearms with non-sterile sleeves if long-sleeve scrub tops have not been used.
    3. Remove the shoe covers, stepping onto the tacky mat in front of the ISO8 anteroom door with each foot after the shoe cover has been removed. Ensure the entire foot makes contact with the tacky mat prior to entry. Discard the shoe covers, and decontaminate the gloves and door handle with 70% sterile isopropyl alcohol (sIPA). Enter the ISO8 anteroom.
    4. Gather a sterile hood, sterile face mask, sterile coveralls, sterile boot covers, and safety glasses. Decontaminate the gloves with 70% sIPA. Don safety glasses, and stage the materials onto a clean surface, as per step 1.5.
    5. Don a new pair of non-sterile shoe covers over the dedicated cleanroom shoes, and step onto the tacky mat in front of the secondary anteroom. Make sure the entirety of each foot makes contact with the tacky mat. Decontaminate the gloves with 70% sIPA. Gather the staged gowning supplies, and enter the secondary ISO7 anteroom, remaining on the dirty side of the demarcation line.
    6. Don the sterile hood and the sterile coverall, touching only the inside of the gowning material and ensuring the neck of the hood is tucked inside the coverall to create a complete seal. Don the secondary sterile boot covers. Decontaminate the gloves with 70% sIPA in between each donning step.
    7. Verify that the gowning has been donned appropriately, decontaminate the gloves with 70% sIPA, and enter the ISO7 space.
      NOTE: Periodically inspect the gowning material for integrity. If compromised, exit the cleanroom immediately and re-gown.
  2. Donning for a biological safety cabinet (BSC)
    1. Gown as per step 1.1 above with these additional practices.
    2. Gather sterile gloves and sterile sleeves. Clean the BSC as per step 1.4, and stage the materials as per step 1.5. Decontaminate the gloves with 70% sIPA.
    3. Aseptically don sterile sleeves over the coverall, using thumb loops if present. Don sterile gloves over existing gloves, ensuring the cuff of the glove extends over the sterile sleeve. Decontaminate the gloves with 70% sIPA between each step. Enter the BSC.
      NOTE: Periodically inspect the gowning material for integrity. If compromised, exit the cleanroom immediately and re-gown.
  3. Doffing of the gowning materials
    1. Exit the BSC, and carefully remove the top pair of gloves and sterile sleeves. Decontaminate the inner gloves with 70% sIPA.
    2. Enter the secondary and then primary anteroom, waiting for the door to close fully between each step. Remove the materials in the following order: outer sterile boot covers, coverall, hood, and face mask.
    3. Exit the primary anteroom, and remove the non-sterile gowning.
      NOTE: The order of removal in the unclassified space is not important; however, the inner non-sterile shoe covers should remain on the cleanroom shoes for storage in non-classified spaces.
    4. Sanitize the hands using an alcohol-based hand sanitizer, and return to street clothes.
  4. Cleaning the cleanroom surfaces and the BSC
    1. Assemble a handheld cleaning mop, or obtain a clean low-lint wipe. If using a low-lint wipe, fold the wipe into quarters, and rotate between each surface. Saturate the mop head or low-lint wipe with an approved disinfectant.
    2. Working from back to front (or top to bottom), clean the BSC using overlapping wipes in the following order: the HEPA diffuser grill (the top of the BSC), the back wall of the BSC, both side walls of the BSC, the sash, and the work surface. Finally, wipe the sash of the BSC using 70% sIPA to remove any residual disinfectant. Refer to Figure 1 for a typical BSC cleaning pattern.
  5. Staging materials and equipment into classified environments
    1. Decontaminate (i.e., stage) all the materials requiring transfer from a non-classified or lower-classified area to a higher-classified area (e.g., from an ISO8 to ISO7 space) to minimize the transfer of microbes. The transfer of materials between areas of the same ISO classification level does not require staging.
      NOTE: If the materials have been terminally sterilized and are in multiple bags, remove the outer bag/pouch, and move the material into the classified space; wiping of the internal bag/pouch is not required.
    2. Obtain a low-lint wipe, and fold the wipe into quarters to rotate to a clean side as the wipe becomes soiled. Saturate the wipe with 70% sIPA or an approved disinfectant.
    3. Wipe the exterior of the material/equipment using overlapping wipes. Ensure all the areas of the item are wiped, including the insides of pull-apart package seals and nooks/indents on the equipment and other irregularly shaped supplies. For equipment on wheels, ensure the entire wheel has been wiped during the staging process (the equipment may need to be gently tipped to allow the wheels to be rotated).

Figure 1
Figure 1: Example of a BSC cleaning pattern. Working from back to front (or top to bottom), clean the BSC using overlapping wipes in the following order: the HEPA diffuser grill (the top of the BSC), the back wall of the BSC, both side walls of the BSC, the sash, and the work surface. Finally, wipe the sash of the BSC using 70% sIPA to remove any residual disinfectant. Please click here to view a larger version of this figure.

2. Environmental monitoring (EM)

  1. Viable surface sampling
    1. Stage the materials needed for the sampling session as per step 1.5, and gown into the classified space as per section 1.
      NOTE: The surface sampling should be performed prior to the air sampling at any specified location. If using multiple plates to surface-sample an area, do not sample the exact same location. Use contact plates to sample flat surfaces only to ensure full contact and to avoid potential damage to the agar.
    2. Collect and label one tryptic soy agar with lecithinase and tween (TSALT) plate and one Sabouraud dextrose agar with lecithinase and tween (SABLT) plate for each sampling site. Holding the bottom of the plate with one hand, aseptically remove the lid, being careful not to touch the raised agar surface.
    3. Touch the raised agar to the surface being sampled, ensuring that the entire surface is in contact, and apply firm pressure to the plate. Leave the plate in contact with the surface for at least 5 s.
    4. CRITICAL: Do not move the plate laterally over the surface being sampled, as this can spread potential growth over the surface area, making the resolution of individual colonies difficult. Do not exert excessive force on the contact plate during sampling, as the agar surface may crack.
    5. Aseptically replace the cover, being careful to not touch the raised agar surface. Lock the cover in place if the contact plate has a locking system. Clean the sampling area with 70% sIPA to remove any residual medium from the surface. Loosely bag the plates, and incubate the cultures as described in Table 1. A representative image showing growth of three colony forming units (CFUs) with two distinct colony morphologies on a TSALT surface sampling plate is illustrated in Figure 2. Figure 3 shows contamination of a TSALT plate with growth on the edge of the plate, attributable to poor aseptic technique during sample collection.
  2. Viable air sampling
    1. Stage the materials needed for the sampling session as per step 1.5, and gown into the classified space as per section 1.
    2. Collect and label one tryptic soy agar (TSA) plate and one Sabouraud dextrose agar (SAB) plate for each sampling site. Prepare the air sampler by aseptically removing the sampling head by gripping only the outside edge to avoid contaminating the head.
    3. Holding the sampling head in one hand, aseptically place the medium into the plate holder on the sampler. If there is a prong that is longer than the others, insert the medium against the longer prong first, and then push the plate down into the remaining prongs to secure the plate.
    4. Aseptically remove the plate lid, and place it on a cleaned surface out of the way until the sampling has been completed. Aseptically replace and secure the sampling head, gripping only the outside edge to avoid contaminating the head. Repeat steps 2.2.2-2.2.4 for the remaining medium if using a multi-headed air sampler.
    5. Place the air sampler in the sampling location with the sampling heads facing in the predominant direction of the airflow movement. Ensure the exhaust from the non-viable air sampler (if sampling simultaneously) does not interfere with the viable sampler. Ensure that the air sampler is set to the validated settings, and start the sampling cycle.
    6. When the sampling cycle has been completed, aseptically remove the sampling head from the sampler by gripping only the outside edge to avoid contaminating the head. Hold the sampling head in one hand, and aseptically replace the lid of the agar plate. Remove the plate from the plate holder. Loosely bag the plates, and incubate the cultures as described in Table 1.
    7. Disinfect the sampling head and the area around the plate holder with 70% sIPA. Aseptically secure the sampling head, gripping only the outside edge. Repeat step 2.2.6 and step 2.2.7 for the remaining medium if using a multi-headed air sampler.
      NOTE: Figure 4 shows a TSA active air sampling culture with growth caused by a contaminated sampling head. Conversely, Figure 5 represents a TSA active air sampling culture with no growth. Air impact indents from the sampling head can be seen on the image.
  3. Non-viable sampling
    1. Perform a zero check on the laser particle counter prior to the sampling activities for each day of use. Attach the isokinetic head to the sampling port of the particle counter either directly or affixed to a length of tubing as needed for the sampling location.
    2. If tubing is applied, use a short length, because tubing >1 m long can cause problems with enumerating particles of ≥1 µm and may also lead to unnecessary bends in the tube. Ensure the particle counter is set to the validated settings. It is recommended to set a delay of approximately 30 s to allow exit from the sampling area to avoid airflow disruption during sampling.
    3. Position the laser particle counter's isokinetic head in the sampling location with the isokinetic head facing into the predominant direction of airflow movement. Ensure the exhaust from the viable air sampler (if sampling simultaneously) does not interfere with the non-viable sampler. For areas where the airflow is not unidirectional or the airflow pattern is unknown, ensure the isokinetic head faces vertically upward.
      NOTE: If rotational disinfectant or 70% sIPA has been aerosolized near the air sampler, wait at least 5 min before starting the sampling cycle.
    4. Start the sampling cycle, and slowly exit the sampling area to avoid disrupting the airflow.
      CRITICAL: Do not aerosolize liquids near the air sampler during a sampling cycle, as this will cause high non-viable counts.
    5. When the sampling has been completed, retrieve the laser particle counter. Record the average particle counts for 0.5 µm. Some facilities may also track and trend 5.0 µm.
    6. Repeat the steps 2.3.3-2.3.6 for the next sampling location. If moving between rooms or BSCs, wipe the outside of the non-viable particle sampler with 70% sIPA or an approved disinfectant. Avoid getting disinfectant inside the isokinetic head, as this could lead to inaccurate particle counts.
Category Media Culture conditions Culture observation Results
Environmental monitoring TSA (viable air) 30 °C-35 °C, air, for at least 3 days End of incubation The QA group of each facility should establish alert and action limits for each sampling type and location. Action limits for viable samples based on ISO classification can be guided using PIC/S 009-16 (Annexes) 18 and ISO-14644-1 7. Action limits for non-viable air samples are typically set to a percentage of the ISO limit (e.g., 99%). Alert limits for viable samples are typically set to a percentage of the Action limit or ISO limit (e.g., 95%). Refer to PDA TR-13 and USP<1116> for more details regarding establishment of alert and action levels and validating selected culture conditions 8,9
SAB (viable air) 20 °C-25 °C, air, for at least 7 days
TSALT (viable surface) 30 °C-35 °C, air, for at least 3 days Representative images of EM plates are shown in Figure 2, Figure 3, Figure 4, and Figure 5
SABLT (viable surface) 20 °C-25 °C, air, for at least 7 days
Process monitoring TSA (settling plate) 30 °C-35 °C, air, for at least 3 days For information only. Provides useful information in the event of an OOS investigation in response to a failed product sterility test.
SAB (settling plate) 20 °C-25 °C, air, for at least 7 days See Figure 6 for an example of a positive settling plate.
Gloved fingertip sampling TSALT 30 °C-35 °C, air, for at least 48 hours days followed by 20 °C-25 °C for at least 5 days 19. The acceptability criteria for GFS is <1 CFU/plate (i.e., no growth) as per PIC/S 009-16 (Annexes) 18. Acceptability criteria may be modified at the discretion of facility QA. 
Product sterility testing TSB (USP<71>) 20 °C-25 °C, air, for at least 14 days Periodically throughout the incubation period (days 3, 5, 7, and 14) No growth. 
FTM (USP<71>) 30 °C-35 °C, air, for at least 14 days
iFA+ (NIH method) 30 °C-35 °C, air, for at least 14 days Monitoring automatically by the BacT/ALERT Dual-T instrument. Visual check of each bottle at the end of incubation for mold balls is strongly recommended. See Figure 8 for an example of visible mold balls that failed to be automatically detected by the BacT/ALERT.
iFN+ (NIH method)
SAB (NIH method) 20 °C-25 °C for at least 14 days Periodically throughout the incubation period (days 3, 5, 7, and 14)

Table 1: Summary of the recommended culture conditions and expected results. The culture conditions described here are recommendations based on a validated program used at the NIH. Each end-user is required to validate their own microbiology testing program. The microbial control and testing strategies may differ between institutes depending on variables including the facility design, facility flora, and product risk classification.

Figure 3
Figure 2: Growth on the TSALT plate. The TSALT surface sampling plate showing three CFUs of two distinct colony morphologies. Please click here to view a larger version of this figure.

Figure 4
Figure 3: Contamination of the TSALT plate during collection. The TSALT surface culture showing a single colony on the edge of the plate, indicative of poor aseptic handling during the sampling process. Please click here to view a larger version of this figure.

Figure 5
Figure 4: Culture obtained using a contaminated air sampling head. Example of a TSA active air sampling culture showing >100 colony forming units (CFU) of mixed morphologies. The pattern of growth indicates contamination of the sampling head. Please click here to view a larger version of this figure.

Figure 6
Figure 5: No growth on a TSA active viable air plate. TSA active viable air plate illustrating no growth following incubation. Indents from the active air sampler head can be seen in the image. Please click here to view a larger version of this figure.

3. Process monitoring

  1. Settling plates (passive air monitoring)
    1. Place labeled TSA and SAB plates near the work area but in an area that will not interfere with testing. Document the sampling start time, and aseptically open both plates, placing the lids on a clean surface in the BSC away from the work area.
    2. The settling plates may be open for a maximum duration of 4 h to prevent the agar from drying out. Close the lids of the plates at the end of the processing. Loosely bag the plates, and incubate the cultures as described in Table 1. Figure 6 shows a single colony contaminant on a TSA air settling plate.
  2. Gloved fingertip sampling (GFS)
    1. Obtain two labeled TSALT plates. Aseptically remove the lid of one plate, and place it on a clean work surface away from the sampling area.
    2. Gently roll the pad of each finger and thumb of one hand on the surface of the plate (Figure 7). Sample the largest surface area of each finger/thumb rather than the tip. Use sufficient force to make slight depressions on the agar without cracking the agar surface.
    3. Aseptically place the lid back onto the plate, and repeat step 3.2.2 for the other hand. Sanitize the hands with 70% sIPA at the completion of sampling. Loosely bag the plates, and incubate the cultures as described in Table 1.

Figure 7
Figure 6: Growth on a TSA air settling plate. A TSA air settling plate illustrating a single colony of a contaminant cultured during passive air process monitoring in the BSC. Please click here to view a larger version of this figure.

Figure 2
Figure 7: Gloved fingertip sampling. The correct method for obtaining gloved fingertip samples using the largest surface area (or pad) of each finger/thumb is shown on the left. The incorrect process where only the fingertip is sampled is shown on the right. Please click here to view a larger version of this figure.

4. Sterility testing by direct product inoculation

  1. Direct inoculation following USP<71>
    1. Obtain one labeled tryptic soy broth (TSB) bottle and one labeled fluid thioglycolate medium (FTM) bottle for each test article submitted. For the testing session, obtain one TSALT and one SABLT for viable surface sampling, one TSA and one SAB plate for settling plates, and two TSALT plates for GFS.
    2. Gown for work inside the BSC as per step 1.2. Clean the BSC as per step 1.4. Stage the materials into the BSC as per step 1.5. Perform contact sampling of the critical work area as per step 2.1, wiping the surface with 70% sIPA after sampling. Prepare the TSA and SAB settling plates near the work area as per step 3.1.
    3. Obtain the test article and the associated TSB and FTM bottles. If the TSB and FTM bottles have a septum, remove the protective caps from each bottle, and wipe the septum with a sterile alcohol wipe. If the TSB and FTM bottles have a screw top, loosen the cap from the bottles (but do not remove the cap).
    4. Vortex the test article to ensure a homogenous suspension. Inoculate the bottles with the validated volume of the test article (up to 10 mL/bottle) using a sterile syringe and a hypodermic needle (for septum caps) or a pipettor (for screw caps).
    5. After inoculation, wipe the septum with a sterile alcohol wipe, and insert a sterile venting unit to allow for air exchange during incubation. For screw-top bottles, close the bottle but leave the cap 1/4 to 1/2 a turn loose to allow for air exchange during incubation. Repeat steps 4.1.3-4.1.5 for each test article to be tested within that session.
    6. Aseptically close the TSA and SAB settling plates, and document the sampling end time. Perform GFS as per step 3.2, wiping the gloves with 70% sIPA after sampling. Loosely bag the plates, and incubate the cultures as described in Table 1.
    7. Transfer all the test materials out of the BSC, and clean the BSC as per step 1.4.
  2. Direct inoculation following the NIH Alternative Sterility Testing Method
    1. Obtain one labeled iFA+, one labeled iFN+, and one SAB plate for each test article. For the testing session, obtain one TSALT and one SABLT for viable surface sampling, one TSA and one SAB plate for settling plates, and two TSALT plates for GFS.
    2. Gown for work inside the BSC as per step 1.2. Clean the BSC as per step 1.4. Stage the materials into the BSC as per step 1.5. Perform contact sampling of the critical work area as per step 2.1, wiping the surface with 70% sIPA after sampling. Prepare the TSA and SAB settling plates near the work area as per step 3.1.
    3. Obtain the test article and the associated iFA+, iFN+, and SAB plate. Remove the protective caps from the iFA+ and iFN+ bottles, and wipe the septum with a sterile alcohol wipe.
    4. Vortex the test article to ensure a homogenous suspension. Inoculate the bottles with the validated volume of the test article (up to 10 mL/bottle) using a sterile syringe and hypodermic needle. Wipe the septum with a sterile alcohol wipe after inoculation. Incubate the bottles on the BacT/ALERT Dual-T instrument as described in Table 1.
    5. Using a pipettor, inoculate the SAB plate with the validated amount of the test article (no more than 500 µL/plate), and streak for isolation using a sterile loop. Let stand for 10 min to ensure the sample does not run onto the plate lid when inverted for incubation. Place each SAB plate inoculated with the test article into a plastic bag, tie loosely, and incubate as described in Table 1.
    6. Aseptically close the TSA and SAB settling plates, and document the sampling end time. Perform GFS as described in step 3.2, wiping the gloves with 70% sIPA after sampling. Loosely bag the plates, and incubate the cultures as described in Table 1. Visual inspection of the BacT/ALERT bottles at the end of the incubation period is essential for detecting mold balls that may have gone undetected by the instrument (Figure 8).
    7. Transfer all the test materials out of the BSC, and clean the BSC as per step 1.4.

Figure 8
Figure 8: Growth of mold that failed to be detected by the BacT/ALERT. Example of mold balls, visible to the naked eye, that failed to be automatically detected by the BacT/ALERT system. Based on these findings, we recommend terminal visual inspection of all BacT/ALERT bottles and the addition of the SAB plate for fungal culture using the NIH Alternative Sterility Testing Method. Please click here to view a larger version of this figure.

Subscription Required. Please recommend JoVE to your librarian.

Representative Results

The expected results are described in Table 1. The EM data should be reviewed and followed up with an appropriate investigation and response to action, alert, or ISO limit excursions. If an excursion occurs for non-viable particles, one should proceed as per ISO 14644-Annex A, sec A.5.57. If the excursion can be attributed to an immediately identifiable abnormal occurrence, the original sampling results should be documented, a note should be added to disregard the original results, and a detailed description of the abnormal occurrence should be provided. Another sample may be taken at the site in question. If the excursion cannot be attributed to an immediately identifiable abnormal occurrence, document the sampling result. Take another set of non-viable samples at the site in question immediately after identifying the out of specification (OOS) result. This can be used as part of the investigation. As per ISO 14644-Annex A, section A.5.6, investigate the OOS finding and remediate the identified root cause.

A failed product sterility test will result in turbidity of the USP<71> culture or growth in the BacT/ALERT bottles and/or SAB plate (Figure 8). The organism should be identified to the species level, and appropriate susceptibility testing should be performed, if clinically warranted. An investigation should be completed by the testing laboratory to determine if the OOS result is valid or if there was any potential laboratory error that may have contributed to the OOS. Testing of the retention sample is strongly recommended. The decision to withhold or release the product for infusion should be made by the patient's clinical care team, and by the manufacturing, microbiology, infectious diseases, quality assurance, and regulatory affairs team. For HCT/Ps that may have already been infused based on preliminary in-process testing, the patient should be carefully monitored, and an event report should be submitted to the appropriate regulatory agency.

Subscription Required. Please recommend JoVE to your librarian.

Discussion

There are several critical areas in this protocol, including the maintenance of aseptic technique and unidirectional airflow within cleanrooms and the BSCs. Best practices include moving slowly and deliberately to minimize turbulence. Aseptic manipulations should be performed from the side of the product, not from above. Closed system processing and the use of terminally sterilized raw materials are recommended. Speaking in critical areas and leaning against walls or equipment should be avoided. Similarly, unnecessary touching of non-sterile items and picking up fallen items should be avoided until the sterile processing has been completed. The materials in the BSC should be arranged to prevent blockage of the airflow and to maintain unidirectional movement from clean to dirty. Operator movement in and out of the BSC should be minimized. The documentation of all activities including lot numbers, expiration dates, calibration dates, start/stop times, and testing personnel for all the materials, equipment, and processes within a sampling or testing session is also critical.

The EM procedure described here relies on manual incubation and colony counting. The design of an EM program is at the discretion of the end user. The sampling locations and test frequency should be guided by PDA Technical Report 138 and justified by a risk assessment that incorporates the laboratory workflow, product proximity, site criticality, duration, and the number of personnel for each workflow step8. A typical EM program should incorporate the total air particulates (0.5 μm non-viable particles), viable air sampling (1,000 L), and viable surface sampling collected under dynamic conditions at a frequency based on product risk and historical trends. Weekly sampling is generally recommended for new facilities until sufficient data trends have been established. General guidance for EM and culture conditions is provided in Table 1 and in USP<1116>9; however, others have evaluated different culture conditions, such as medium that was limited to TSA/TSALT only, and different incubation temperatures, including dual temperatures10,11. Automated EM instruments that combine incubation with colony count plate reading are commonly used in the pharmaceutical market as rapid methods8,12. The chosen EM program must be validated and is typically dependent on the facility flora, incubator capacity, test volume, and personnel capacity. Furthermore, an established EM program should have an active life cycle, with relevant adjustments made to the collection sites, test frequency, and/or alert/action limits based on an annual review and a data-driven risk assessment8. Major changes to EM trends may trigger the re-evaluation of the cleaning program. Disinfectants should be validated via a disinfectant efficacy study using representative material surfaces against facility flora for the prescribed contact time, as described in USP<1072>13. Typical disinfectants may include Vesphene III (contact time: 10 min), LpH III (contact time: 10 min), and a sporicidal agent such as Peridox RTU (contact time: 5 min). For best practices, disinfectants should be rotated on a monthly basis, and the outlets, mechanical connections, and work surfaces that are under equipment in the BSC should be cleaned routinely.

The minimum product volume that must be tested for sterility is defined in USP<71>3 and is based on the total final product volume. Unfortunately, USP<71> was designed originally for sterile drug products and is recognized to be unsuitable for short shelf-life products due to the slow turnaround time and high product test volume14. USP<1071> acknowledges that alternative rapid microbial methods may be beneficial and that lower product testing volumes may be acceptable when a risk-based approach has been applied14. Given the limitations of USP<71> for the sterility testing of cellular therapy products, alternative methods such as automated BacT/ALERT respiration methods have been used in industry1,4,6. However, any use of an alternative testing method requires rigorous end-user validation to demonstrate non-inferiority to the compendial USP<71> method for that product5,15,16. Method suitability testing for each new product is also required to ensure that the product, at the chosen inoculation volume and test conditions, is not inhibitory to the detection of low-level contaminants6. Therefore, it is possible that the test volume and inoculation volume may vary between products depending on the outcome of the validation studies. Membrane filtration, a secondary method outlined in USP<71>, may be used to sample a larger sample volume in a single test. Validation and method suitability testing should include organisms beyond the six compendial QC isolates. Focus should be given to frequently recovered facility flora and previous product contaminants. Particular attention should be given to fungi, as respiration methods alone have demonstrated suboptimal performance4,17, which is why the NIH Alternative Sterility Testing Method includes a paired fungal culture on SAB and a terminal visual inspection of the BacT/ALERT bottles.

A major limitation for any microbial control program is the retrospective nature in which results are available. Gold standard testing is culture-based, which is slow and can lead to constant reactive measures for corrective action. Faster testing methods require rigorous validation, but these still cannot provide real-time assurance of microbial monitoring and control. Furthermore, microbiological cultures capture only a small subset of time during a production or testing session. Therefore, it is critical that active microbial monitoring occurs on a frequent risk-justified basis to ensure that the trend data is well-established. This will enable the use of appropriately set alert limits to predict potential deviations from microbial control before they occur.

The establishment of a robust cGTP/cGMP program takes time and effort and, unfortunately, cannot be simply transferred from one facility to another. The United States Food and Drug Administration expects that all programs undergo end-user validation testing despite the potential availability of third-party published results demonstrating their efficacy. Therefore, microbial control and testing strategies may differ between institutes depending on variables including the facility design, facility flora, and product risk classification. The strategies outlined in this protocol help provide a framework through which to establish a robust microbial monitoring and control program for cGTP/cGMP laboratories.

Subscription Required. Please recommend JoVE to your librarian.

Disclosures

The authors declare no conflicts of interest.

Acknowledgments

This work was supported by the Intramural Research Program of the National Institutes of Health Clinical Center. The content is solely the responsibility of the authors and does not represent the official views of the National Institutes of Health.

Materials

Name Company Catalog Number Comments
20-25°C Incubator Lab preference
30-35°C Incubator Lab preference
Alcohol-based hand sanitizer Lab preference
BacT/ALERT Dual-T instrument BioMerieux Industry
Beard cover Lab preference
Biosafety cabinet (BSC) Lab preference
Cleanroom shoes Lab preference
Fluidthioglycollate medium (FTM) Hardy Diagnostics  U84 USP
Handheld cleaning mop Contec 2665LF
Hypodermic needle Lab preference
iFA+ BacT/ALERT bottle Biomerieux 412990
iFN+ BacT/ALERT bottle Biomerieux 412991
Isokinetic head Lab preference
Laser particle counter TSI Incorporated 9500-01
LpH III Steris 1S16CX
Mirror Lab preference
Non-sterile bouffant Lab preference
Non-sterile gloves Lab preference
Non-sterile shoe covers Lab preference
Non-sterile sleeve covers Lab preference
Parafilm Lab preference
Peridox RTU Contec CR85335IR
Plastic bag Lab preference
Sabouraud Dextrose Agar with Lecithinase and Tween (SABLT) Hardy Diagnostics  P595 USP, irradiated
Sabouraurd Dextrose Agar (SAB) Hardy Diagnostics  W565 USP, irradiated
Safety glasses Lab preference
Scrubs (top and bottom) Lab preference
Spor-Klenx RTU Steris 6525M2
Sterile 70% isopropyl alcohol (IPA) Decon CiDehol 8316
Sterile alcohol wipe Lab preference
Sterile boot covers Kimberly Clark Cat# varies based on size
Sterile coveralls Kimberly Clark Cat# varies based on size
Sterile face mask Lab preference
Sterile gloves Lab preference
Sterile hood Kimberly Clark Cat# varies based on size
Sterile low-lint wipes Texwipe TX3210
Sterile mop cleaning pads Contec MEQT0002SZ
Sterile sleeve covers Kimberly Clark 36077
Sterile spreading rod Fisher Scientific 14665231
Sterile syringe Lab preference
Tacky mats Lab preference
Tryptic Soy Agar (TSA) Hardy Diagnostics  W570R USP, irradiated
Tryptic Soy Agar with Lecithinase and Tween (TSALT) Hardy Diagnostics  P520R USP, irradiated
Tryptic Soy Broth (TSB) Hardy Diagnostics  U46 USP
Tubing Lab preference
Vesphene III Steris 1S15CX
Viable air sampler Hardy Diagnostics  BAS22K
Vortex Lab preference

DOWNLOAD MATERIALS LIST

References

  1. Cundell, T., Atkins, J. W., Lau, A. F. Sterility testing for hematopoietic stem cells. Journal of Clinical Microbiology. , 10.1128/jcm.01654-22 (2023).
  2. United States Food and Drug Administration. Guidance for Industry. Sterile Drug Products Produced by Aseptic Processing - Current Good Manufacturing Practice. United States Food and Drug Administration. , (2004).
  3. United States Pharmacopeia - National Formulary. USP<71> Sterility Tests in USP43-NF38. United States Pharmacopeia - National Formulary. , (2022).
  4. England, M. R., Stock, F., Gebo, J. E. T., Frank, K. M., Lau, A. F. Comprehensive evaluation of compendial USP<71>, BacT/Alert Dual-T, and Bactec FX for detection of product sterility testing contaminants. Journal of Clinical Microbiology. 57 (2), 01548 (2019).
  5. Gebo, J. E. T., East, A. D., Lau, A. F. A side-by-side comparison of clinical versus current good manufacturing practices (cGMP) microbiology laboratory requirements for sterility testing of cellular and gene therapy products. Clinical Microbiology Newsletter. 43 (21), 181-191 (2021).
  6. Gebo, J. E. T., Lau, A. F. Sterility testing for cellular therapies: What is the role of the clinical microbiology laboratory. Journal of Clinical Microbiology. 58 (7), 01492 (2020).
  7. International Organization for Standardization. ISO 14644-1:2015 Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness by particle concentration. International Organization for Standardization. , (2015).
  8. Parenteral Drug Association. PDA Technical Report No. 13 Revised 2022 (TR 13) Fundamentals of an Environmental Monitoring Program. Parenteral Drug Association, Inc. , (2022).
  9. United States Pharmacopeia - National Formulary. USP<1116> Microbiological Evaluation of Cleanrooms and Other Controlled Environments in USP43-NF38 2S. United States Pharmacopeia - National Formulary. , (2020).
  10. Guinet, R., et al. Multicenter study on incubation conditions for environmental monitoring and aseptic process simulation. PDA journal of pharmaceutical science and technology. 71 (1), 43-49 (2017).
  11. Gordon, O., Berchtold, M., Staerk, A., Roesti, D. Comparison of different incubation conditions for microbiological environmental monitoring. PDA Journal of Pharmaceutical Science and Technology. 68 (5), 394-406 (2014).
  12. Anders, H. J., et al. Multisite qualification of an automated incubator and colony counter for environmental and bioburden applications in pharmaceutical microbiology. PDA Journal of Pharmaceutical Science and Technology. , (2022).
  13. United States Pharmacopeia - National Formulary. USP<1072> Disinfectants and Antiseptics. United States Pharmacopeia - National Formulary. , (2020).
  14. United States Pharmacopeia - National Formulary. USP<1071> Rapid Microbial Tests for Release of Sterile Short-Life Products: A Risk-Based Approach in USP43-NF38 2S. United States Pharmacopeia - National Formulary. , (2020).
  15. United States Pharmacopeia - National Formulary. PUSP<1223> Validation of Alternative Microbiological Methods in USP43-NF38 2S. United States Pharmacopeia - National Formulary. , (2020).
  16. Parenteral Drug Association. PDA Technical Report No. 33, Revised 2013 (TR 33) Evaluation, Validation and Implementation of Alternative and Rapid Microbiological Methods. Parenteral Drug Association, Inc. , (2013).
  17. Putnam, N. E., Lau, A. F. Comprehensive study identifies a sensitive, low-risk, closed-system model for detection of fungal contaminants in cell and gene therapy products. Journal of Clinical Microbiology. 59 (11), 0135721 (2021).
  18. Pharmaceutical Inspection Convention & Pharmaceutical Inspection Co-operation. Guide to Good Manufacturing Practice for Medicinal Products Annexes (PE 009-16 (Annexes)). Pharmaceutical Inspection Convention & Pharmaceutical Inspection Co-operation Scheme. , (2022).
  19. United States Pharmacopeia - National Formulary. USP<825> Radiopharmaceuticals - Preparation, Compounding, Dispensing, and Repackaging in USP43-NF38 2S. United States Pharmacopeia - National Formulary. , (2020).

Tags

Microbial Control Monitoring Strategies Cleanroom Environments Cellular Therapies Sterility Testing Clinical Microbiology Labs CGMP Setting Academic And Clinical Laboratories Culture-based Methods Newer Technologies Regulatory Requirement End-user Validations Standardization In CGMP Risk-based Approach Clinical Setting Blood Culture Systems Differences Between Clinical And CGMP Microbiology Labs
Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Play Video
PDF DOI DOWNLOAD MATERIALS LIST

Cite this Article

East, A. D., Gebo, J. E. T., Lau, A. More

East, A. D., Gebo, J. E. T., Lau, A. F. Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies. J. Vis. Exp. (193), e65209, doi:10.3791/65209 (2023).

Less