-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
<<<<<<< HEAD
K12 Schools
Biopharma
=======
K12 Schools
>>>>>>> dee1fd4 (fixed header link)

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Medicine
Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capn...
Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capn...
JoVE Journal
Medicine
Author Produced
This content is Free Access.
JoVE Journal Medicine
Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor

Full Text
9,498 Views
07:51 min
September 29, 2020

DOI: 10.3791/61670-v

Ruben D. Restrepo1, Ido Karpenkop2, Katherine E. Liu3

1Division of Respiratory Care,UT Health Science Center at San Antonio, 2Research and Development, OEM Engineering, Patient Monitoring,Medtronic, Jerusalem, 3Minimally Invasive Therapies Group, Scientific Communications,Medtronic, Minneapolis

The goal of this study was to evaluate the accuracy of capnography sampling lines used in conjunction with a portable bedside capnography monitor. Sampling lines from 7 manufacturers were evaluated for tensile strength, rise time, and ETCO2 accuracy as a function of respiratory rate or supplemental oxygen flow rate.

This bench test, performed in combination with a portable bedside capnography monitor allows us to determine the accuracy of match and crosspaired capnography sampling lines. The main advantage of this technique is that it can be used to directly compare the accuracy of multiply capnography sampling lines under consistent control testing condition. Capnography sampling line accuracy evaluation is essential for a variety of clinical settings in which accurate and reliable end tidal carbon dioxide measurements are vital to understanding a patient's ventilatory status.

To calibrate the tensile testing jig in the tensile testing jig software, set the load cell selection to 100 kilograms and the load parameter to 10 kilograms. Attach the sampling line components to the calibrated tensile testing jig and starting with a mass of zero kilograms initiate tension on the sampling line component while observing whether the sampling line connection remains intact. If the connection remains intact automatically and continuously increase the tension until the sub parts break or disconnect, recording the maximum tension exerted before the break occurred.

To calibrate the rise time measurement device first cut a standard 0.95 millimeter internal diameter carbon dioxide PVC tube into 10, 15 centimeter pieces. Next, turn on the air compressor jig controller and power supply and open the carbon dioxide gas flow. Attach one of the 15 centimeter pieces of PVC directly to the measurement chamber as a sampling channel and use a mass flow meter and a dedicated restrictor to calibrate the airflow to 10 liters per minute and the carbon dioxide sampling rate to 50 milliliters per minute.

In the jig software, set the air to carbon dioxide ratio to one to one the air time to three seconds, the carbon dioxide time to three seconds and 10 cycles and the rise time measurement length to none. Open the carbon dioxide valve and click finish calibration confirm that the button has turned green. Click measure and wait for the gas flow cycles to end before closing the carbon dioxide valve.

Record the background rise time and confirm that the result is less than 60 milliseconds. Open a new commercial sampling line and connect the sampling line to the rise time measurement device. Then click start, in the rise time measurement device software and wait for the device to measure the rise time.

To measure the end tidal carbon dioxide accuracy as a function of the respiratory rate. Place a mannequin in the supine position and connect the sampling line to the mannequin according to the manufacturer's instructions. To control the simulated respiratory rate, use a flow meter to measure the gas flow and calibrate the flow to 10 liters per minute as demonstrated.

In the breath simulator jigs software, set the duty cycle to 50%and use a leak testing jig to test for leaks in the system. When the patency of the sampling line has been confirmed, connect the breath simulator jig to the mannequin and use the simulator to increase the 5%carbon dioxide flow rate to 10 liters per minute and the nitrogen flow rate to 10 liters per minute. Wait 30 seconds to allow a steady capnography waveform to be established before recording the end tidal carbon dioxide value.

After measuring a total of 10 end tidal carbon dioxide values over 180 seconds. Use the breath simulator jig to change the respiration rate and allow the capnography waveform to normalize for 30 seconds before recording 10 additional entitled carbon dioxide readings over 180 seconds. To measure the end tidal carbon dioxide accuracy in the presence of supplemental oxygen.

Set the breathe simulator jig to 10 breaths per minute and connect the oxygen line to 100%oxygen and carbon dioxide output. Increase the carbon dioxide flow rate to six liters per minute and the oxygen flow rate to zero liters per minute for use as a reference measurement. Wait 30 seconds to allow the capnography waveform to stabilize before recording the end tidal carbon dioxide value 10 times over 180 seconds.

Then change the flow rate of the carbon dioxide and oxygen allow the capnography waveform to normalize for 30 seconds and repeat 10 additional end tidal carbon dioxide measurements over 180 seconds. While a majority of the sampling lines in this representative analysis exhibited accuracy at 150 breaths per minute for both breathing ratios, some lines failed to maintain accuracy, while others maintained accuracy under all of the tested conditions. Among the adults sampling lines tested at 10 breaths per minute sampling lines one, two, five, six, seven, eight and nine read end tidal carbon dioxide within an acceptable range at the lowest respiration rates.

In contrast, sampling lines three and four reported low end tidal carbon dioxide levels at the lowest respiration rate, which decrease to zero millimeters of mercury when the respiration rate increased to 80 breaths per minute or higher. Only sampling lines one, eight and nine continued to capture readings at very high respiration rates. In the presence of two, four or six liters per minute of supplemental oxygen, the expected end tidal carbon dioxide was 34 millimeters of mercury.

Upon the addition of two liters per minute of supplemental oxygen, a majority of the sampling lines exhibited a decrease in the observed end tidal carbon dioxide values. Similar decreases were also obtained in the presence of four or six liters per minute of supplemental oxygen. To improve clinical applicability similar end tidal carbon dioxide measurements should be performed in humans to evaluate the accuracy of capnography sampling lines in a clinical setting.

Our assessment of capnography sampling lines, highlights the need for an improved device accuracy evaluation particularly when using sampling lines and monitors from separate manufacturers.

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

CapnographySampling Line CompatibilityAccuracy EvaluationPortable Capnography MonitorEnd Tidal Carbon DioxideClinical SettingsTensile Testing JigMass Flow MeterAir CompressorCarbon Dioxide Sampling RateCalibration ProcedureRise Time MeasurementGas Flow CyclesVentilatory Status

Related Videos

Quantitative Autonomic Testing

11:40

Quantitative Autonomic Testing

Related Videos

58.5K Views

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department

07:52

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department

Related Videos

16.8K Views

Fast and Accurate Exhaled Breath Ammonia Measurement

06:27

Fast and Accurate Exhaled Breath Ammonia Measurement

Related Videos

13.9K Views

Integrated Compensatory Responses in a Human Model of Hemorrhage

07:57

Integrated Compensatory Responses in a Human Model of Hemorrhage

Related Videos

13K Views

A Model to Simulate Clinically Relevant Hypoxia in Humans

09:54

A Model to Simulate Clinically Relevant Hypoxia in Humans

Related Videos

9.3K Views

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise

07:09

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise

Related Videos

13.6K Views

A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients

05:01

A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients

Related Videos

7.4K Views

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship

08:25

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship

Related Videos

9.9K Views

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure

04:20

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure

Related Videos

6.2K Views

Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring

06:46

Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring

Related Videos

3.2K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code