-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Medicine
Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Niti...
Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Niti...
JoVE Journal
Medicine
A subscription to JoVE is required to view this content.  Sign in or start your free trial.
JoVE Journal Medicine
Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model

Full Text
3,375 Views
05:31 min
June 8, 2022

DOI: 10.3791/63661-v

Yimeng Hao1,2, Xiaolin Sun1,2, Jonathan Frederik Sebastian Kiekenap1, Jasper Emeis1, Marvin Steitz2, Alexander Breitenstein-Attach2, Felix Berger1,2, Boris Schmitt1,2,3,4,5

1Department of Pediatric Cardiology and Congenital Heart Disease,Charité University Medicine Berlin, 2Department of Pediatric Cardiology and Congenital Heart Disease,Deutsches Herzzentrum Berlin, 3DZHK (German Centre for Cardiovascular Research) and BMBF (German Ministry of Education and Research), 4BIH (Berlin Institute of Health), 5BCRT (BIH Center of Regenerative Therapies)

This study demonstrates the feasibility and safety of developing an autologous pulmonary valve for implantation at the native pulmonary valve position by using a self-expandable Nitinol stent in an adult sheep model. This is a step toward developing transcatheter pulmonary valve replacement for patients with right ventricular outflow tract dysfunction.

This protocol demonstrates an autologous pulmonary valve with specific characteristics, such as self-repair, regeneration, and growth capacity, to ensure physiological performance and long-term functionality in our patients requiring TPVR. The autologous pulmonary valve can prevent tissue rejection, enable regenerative potential due to living endogenous cells, and does not require any medication intake. This method will provide a longer life expectancy of the implanted heart valve in the treatment of younger patients with right ventricular outflow tract that is dysfunctional.

The autologous heart valve can be modified for transcatheter aortic valve implantation, which can benefit millions of patients suffering from aortic valve disease. To test the autologous pulmonary valve before implantation, hold the stented valve with a surgical tweezer. Lift and leave the valve in 0.9%sodium chloride to test the commissures for sufficient opening and closing of the orifice.

Next, evaluate the degree of native valvular regurgitation in the vena contracta by intra-cardiac echocardiography. Using fluoroscopy via a portable C-arm, perform angiography of the right ventricle and pulmonary artery to guide the implantation. Also, perform functional screen by measuring the diameters of the right ventricular outflow tract, native pulmonary valve annulus, pulmonary bulb, sino-tubular junction, and supervalvular pulmonary artery and identify the landing zone.

Then, advance the loaded delivery system via the pre-shaped guide wire through the right ventricular inflow tract and the right ventricular outflow tract to the position of the native pulmonary valve. Retract the cover tube of the delivery system and deploy the autologous pulmonary valve slowly and directly over the native pulmonary valve in the landing zone at the end of the diastolic phase under fluoroscopic guidance After deployment, carefully retract the tip of the delivery system into the cover tube and retrieve it from the sheep. Repeat intra-cardiac echocardiography and post-implantation angiography for the right ventricle and pulmonary artery.

Follow up post-implantation by performing cardiac-computed tomography to evaluate the stent position and the deformation of the right heart throughout the entire cardiac cycle. Also, assess the relationship between the pulmonary artery and left coronary artery from the final computed tomography. Autologous pulmonary valves were successfully implanted in adult sheep.

Stable hemodynamics throughout the left antero-lateral mini-thoracotomy and after implantation indicated the well-being of the animals. Intra-cardiac echocardiography and angiography assessment immediately after valve deployment showed no signs of paravalvular leak, no pulmonary valve insufficiency, and no valve migration. Post-implantation cardiac-computed tomography showed that implanted stent was anchored in the targeted position without migration.

Final CT analysis showed that blood flow in the left anterior descending artery and left circumflex artery was unaffected throughout the cardiac cycle. The implanted stented autologous pulmonary valve demonstrated favorable function and hemodynamics in the right cardiac system, with only a 5 to 10%regurgitation fraction in follow-up magnetic resonance flow measurements and intra-cardiac echocardiography. For this procedure, it's crucial to harvest the autologous tissue, manufacture a 3D-shaped autologous heart valve, and implant it to the native pulmonary position.

This method will pave the way for the development of a regenerative autologous pulmonary valve replacement that provides a lifetime solution for children with a congenital heart defect.

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

Transcatheter Pulmonary Valve ReplacementAutologous PericardiumSelf-Expandable Nitinol StentAdult Sheep ModelPulmonary ValveRegenerative PotentialHeart Valve FunctionalityRight Ventricular Outflow TractTranscatheter Aortic Valve ImplantationIntra-cardiac EchocardiographyAngiographyDelivery SystemDeploymentCardiac-computed TomographyPulmonary Artery Assessment

Related Videos

Transplantation of Pulmonary Valve Using a Mouse Model of Heterotopic Heart Transplantation

10:56

Transplantation of Pulmonary Valve Using a Mouse Model of Heterotopic Heart Transplantation

Related Videos

19.4K Views

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots

12:17

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots

Related Videos

11.8K Views

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease

06:39

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease

Related Videos

7.2K Views

A Large Animal Model for Pulmonary Hypertension and Right Ventricular Failure: Left Pulmonary Artery Ligation and Progressive Main Pulmonary Artery Banding in Sheep

07:02

A Large Animal Model for Pulmonary Hypertension and Right Ventricular Failure: Left Pulmonary Artery Ligation and Progressive Main Pulmonary Artery Banding in Sheep

Related Videos

3.6K Views

A Rodent Model of The Ross Operation: Syngeneic Pulmonary Artery Graft Implantation in A Systemic Position

11:20

A Rodent Model of The Ross Operation: Syngeneic Pulmonary Artery Graft Implantation in A Systemic Position

Related Videos

3.5K Views

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement

09:57

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement

Related Videos

3.1K Views

Chronic Ovine Model of Right Ventricular Failure and Functional Tricuspid Regurgitation

08:43

Chronic Ovine Model of Right Ventricular Failure and Functional Tricuspid Regurgitation

Related Videos

1.1K Views

A Minimally Invasive Model of Aortic Stenosis in Swine

06:51

A Minimally Invasive Model of Aortic Stenosis in Swine

Related Videos

1.6K Views

An Ex Vivo Porcine Model for Hydrodynamic Testing of Experimental Aortic Valve Procedures and Novel Medical Devices

06:56

An Ex Vivo Porcine Model for Hydrodynamic Testing of Experimental Aortic Valve Procedures and Novel Medical Devices

Related Videos

1.6K Views

Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring

06:29

Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring

Related Videos

740 Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code