Preparation of the heart after IR starts with the reocclusion of blood cardiac arteries and the perfusion of blue dye for the discrimination of at-risk areas from non-risk areas. Methylene blue or Evans blue dyes are most frequently used for this purpose2. As an excessively high pressure might damage heart valves and, thus, partially or completely stain at-risk areas, it is better to perfuse the heart with a pressure-controlled system, such as the Langendorff apparatus or a simplified version of a hydrostatic pressure system-equipped syringe or pump. Controlled perfusion will ensure physiological pressure, and the dye will usually not enter the occluded region of the heart. Both flow speed- and pressure-controlled techniques are safeguards against overstaining.
One of the most serious mistakes in viable tissue processing is keeping tissues in a freezer for a prolonged time before staining. Freezing is mainly used because researchers want to perform heart staining the day after the IR experiment or later. Moreover, freezing is used to make the cutting of the heart easier. We found that short-term freezing of the heart for up to 5-10 min negligibly affects the integrity of heart tissues and facilitates cutting the tissues (particularly for mouse hearts) into thin slices. However, freezing for prolonged periods damages membranes and decreases cell viability and mitochondrial function13. As a result, TTC staining of functioning mitochondria is affected, and the border between necrotic and viable tissues is poorly delineated (blurry). Overall, freezing of rat harts should be avoided, and only short-term freezing of mouse hearts can be used for easier cutting.
The next step is tissue staining in 1% TTC solution at 37 °C14. The staining solution should be prewarmed—particularly important for staining of brain slices. When using the prewarmed solution, the optimal staining time for heart slices is 10 min. A longer incubation or a temperature higher than 37 °C results in brown colorization of the heart tissues. Proper staining of specimens and consistent red color intensity are important for further image analysis. In the final steps before photography, the tissue slices are rinsed 2-3 times with cold PBS or a similar buffer to remove TTC and excess methylene blue from the solution to avoid blue casting in the photograph. Heart slices should be photographed shortly after staining to obtain the best image quality. Heart staining remains of good quality if stored for up to 60 min in the cold (+4 °C) PBS. Stained brain slices and aortic tissues are usually stored in a 4% neutral formaldehyde solution and retain good quality for a week. Overnight storage of brain tissues in formalin (+4 °C) does not impair the color intensity of normal tissue and is acceptable for image acquisition. However, formalin induces swelling and destaining of heart slices. Therefore, the storage of heart tissues in formalin is not recommended.
The next step is image acquisition. Many laboratories use flatbed scanners as an image acquisition tool that is expected to replace a digital camera and lighting setup. We determined that the scanning of slices does not provide sufficient image resolution and color separation and therefore is not suitable for imaging heart slices. In particular, scanner resolution is insufficient for mouse hearts, and we noticed poor rendering of methylene blue. In contrast, a scanner might be an alternative to a photo camera for imaging brain slices stained only with TTC or other single dyes. For the scanning of tissue slices, scanning software that ensures constant exposure settings is essential. Overall, a flatbed scanner is less capable and cannot replace a digital camera for most imaging applications.
The background behind specimens is also important. Ideally, the bottom of the tray should be of a color not present in the stained specimen. For example, to quantify the area of methylene blue and TTC (red) staining in an automated or semiautomated manner, white, red, blue, yellow, and brown backgrounds should be avoided. Thus, a green background would be preferable. Nevertheless, color selection depends on the preferences of the operator, who postprocesses the image. Many scientists prefer a white background because a white background can be deleted in image postprocessing and converted into completely white (RGB white code 255,255,255). Then, one should exclude completely white from the list of selected colors used for semiautomated analysis and count only pale necrotic areas, which are not completely white if not overexposed. Blue and green backgrounds are suitable for the photography of brain slices and aortas.
The optimal imaging tool for tissue photography is a single-lens reflex or mirrorless interchangeable lens digital camera with a compatible macro lens. Capturing very small objects might require a combination of a camera and a microscope; nevertheless, a macro lens usually has sufficient (at least 1:2) magnification to obtain detailed images of a mouse heart. Many manufacturers offer affordable digital cameras and macro lenses to obtain high-resolution and high-magnification photographs. All up-to-date digital cameras have characteristics and functions necessary for macro photography, including the possibility to mount on a stand, a high number of pixels (usually >20 Mpx), live view, mirror lock-up, time-lapse features, remote shutter, and the ability to manually set camera parameters, thus ensuring a constant shutter speed, aperture, white balance, and ISO setting. Compact cameras with the above-mentioned features and lens magnification of at least 1:2 can also be used for macro photography. Because of lens characteristics, some compact cameras should be placed in close proximity to the object, and the experimenter must ensure that the camera body does not affect the illumination of the specimen.
For macro photography with any type of interchangeable lens camera, a high magnification (1:1-1:2) macro lens is required. We suggest using macro lenses with a focal length ranging from 50 mm to 100 (120) mm or equivalent on the full-frame (24 mm x 36 mm) sensor. Smaller sensor cameras have different sensor sizes, and magnification should be recalculated accordingly. For the photography of heart slices, an ergonomic distance of the 100 mm macro lens front element to the subject is approximately 150 mm. This setting allows operators to keep all the equipment on a table, with easy access to the camera controls. A 50 mm macro lens might be considered for photography of larger objects, such as brain slices, because a wider field of view is necessary to obtain all slices in a single photograph.
To obtain sharp images with high resolution, a camera should be mounted onto a sturdy stand, which, together with a light setup, is called a photography copy stand. Mounting the camera on a stand and a remote (wired or wireless) trigger eliminates camera shake and ensures a constant distance from the target. A camera-lighting setup with two constant-light sources from both sides, angled approximately 30-60° relative to the subject plane, ensures sufficient illumination of specimens and helps avoid reflections at the same time. The camera should be mounted precisely so that the sensor is parallel to the subject plane. To evenly illuminate the image field, both lamps should be equally oriented and placed at the same distance from the subject. Light sources placed at various distances from the subject cause uneven illumination. Additionally, blinking light sources are a reason for variations in image exposure. Overall, it is important to accurately place the camera and light sources to precisely acquire images of well-illuminated specimens.
Tissue samples reflect light (glisten), which appear as white spots in the images. These light reflection spots do not contain useful color information, and accordingly, these parts of the images cannot be used for accurate quantitative analysis of images. Light reflections from tissue slices can be removed by various methods. The most efficient is the full immersion of tissue samples in a container with a saline or PBS solution. A similar approach is the insertion of tissue slices below (or between) glass plates. This method is efficient against reflections; however, the image resolution can be lower than that of photographs of immersed tissues.
One can also use a polarizing filter mounted on a lens to eliminate light reflections. Circular polarizing filters are widely available but vary considerably in quality depending on price, and cheap filters can significantly reduce image resolution. Reflected light can be filtered off by turning the moving part of the polarizing filter at an angle. The efficacy of the polarizing filter might be affected by some light sources (e.g., strong LED light). Overall, after removal of extra liquid, a polarizing filter can eliminate all reflections from the brain slices; however, sample immersion in buffer solution is the easiest and most cost-efficient approach for heart slices.
Manual settings of the shutter speed, aperture, ISO, and white balance are important to maintain full control of the imaging process. The sample, background, and characteristics of the light source influence the camera exposure metering system in automatic settings; therefore, manual settings are necessary to maintain constant exposure and white balance between multiple photographs during the experiment. For macro photography, the suggested aperture setting is between f/8 and f/16. By decreasing the aperture, the depth of field increases, which is helpful if the object is not in a single plane. However, diffraction limits the total resolution of photography in the case of smaller apertures. The optimal aperture for most lenses is usually f/10 because in this setting, resolution drop is negligible, and depth of field is sufficient. ISO values that range from 50 to 400 (lower is better) are usually optimal to minimize image artifacts (noise). The shutter speed then remains to be changed to obtain correct exposure using the mentioned aperture and ISO settings in existing light conditions. Manual settings are important for consistent image analysis. Standardized imaging ensures the use of the same color thresholding settings throughout any study, which requires segmentation analysis. For example, semiautomated analysis by ImagePro software based on a segmentation file with predefined colors of blue, red, and white (+pale pink) can be used over the years if specimen images have consistent colors, white balance, and exposure.
The white balance setting should be adjusted depending on the color temperature of the light source that is used to illuminate a sample. White balance can be selected from camera built-in presets or using the manual calibration of a grey target. The benefit of image capturing in RAW format is that white balance can be adjusted during software postprocessing of the image. As RAW files contain much more information than JPEG files, RAW file postprocessing provides an excellent opportunity for the correction of color balance and exposure, as well as to obtain better image resolution. Because most cameras can capture JPEG and RAW files simultaneously, we suggest capturing the RAW file and saving it as a backup.
Overall, this protocol describes a methodology for rat heart and brain tissue slicing and staining and provides guidelines for establishing lighting and camera setups and photography techniques for high-resolution image acquisition for further analysis. This method is applicable to all experimental small-animal organ photography.