-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Bioengineering
High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
JoVE Journal
Bioengineering
This content is Free Access.
JoVE Journal Bioengineering
High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT

Full Text
19,099 Views
08:57 min
June 21, 2011

DOI: 10.3791/2688-v

Amnon Sharir1, Gregory Ramniceanu2, Vlad Brumfeld3

1Department of Molecular Genetics,Weizmann Institute of Science, 2Department of Biological Regulation,Weizmann Institute of Science, 3Department of Chemical Infrastructure,Weizmann Institute of Science

Non-destructive volume visualization can be achieved only by tomographic techniques, of which the most efficient is the x-ray micro computerized tomography ( CT).

The overall goal of this procedure is to perform 3D x-ray micro tomography of mineralized and non mineralized tissues. This is accomplished by first extracting the samples to be examined, then immobilize and position the samples in the micro CT instrument. The third step of the procedure is to set acquisition parameters for each sample and collect the images.

Ultimately, a 3D image of the sample at high resolution through x-ray CT is obtained. The main advantage of this technique of our existing methodologies, like MRI, ultrasound or electron microscopy, is that it provides information about tick volumes at one micron resolution D.This method can provide insight in many biological tissues. It can be used also in electronics, in the material sciences, and in archeology.

Preparation is different for mineralized and non mineralized tissue. Mineralized tissues must be sealed in containers with a tight fit, so sample position does not change. While high resolution measurements are made, the container shape will vary according to the tissue's morphology.

For example, a mouse femur extracted from an 18.5 D old embryo can fit into a pipette tip. Begin by sealing the narrow end of a polystyrene pipette tip with glue like epoxy resin. Then fill the tip with a working buffer.

In this case, PBS now fit the leg with exposed femur tightly into the tip and place the pipette tip into a suitable holder and seal the other end with para film sheet sacrifice and perfuse the animal as outlined in the accompanying manuscript. Then extract the stained lungs and heart and transfer them to a prepared 50 milliliter test tube. Place the organs on a dry piece of paper.

Place the samples in the final measuring test tubes at the bottom of the test tube is an ethanol dampen cloth. To create an ethanol saturated environment, the sample should fit tightly within the tube. If the sample is loose, tighten it with a wire and immobilize it near the bottom of the tube just above the cloth.

Next, glue or screw the tube into a holder of the instrument and proceed with setting the image. Acquisition parameters. Begin by placing the sample holder in the rotation stage of the instrument.

Then using arbitrarily selected values for voltage and current, take an x-ray image. If the image is too dark. Make changes by first gradually increasing the number of photons.

This is done by progressively increasing the current. If the image hasn't gotten brighter after increasing the current to 200 microamps, then make small progressive increases to the energy of the x-ray photons by increasing the voltage. If the image is too bright, first, decrease the voltage, then decrease the current until the image is satisfactory.

Benning can also be used to increase image brightness at the sacrifice of resolution. A inning value of two will make the image about four times brighter at half the resolution. After setting the optimum brightness, optimize the exposure time of the camera to compromise between the best obtainable contrast with a reasonable experiment duration.

Image contrast, especially for samples with high absorption, can be improved by using filters to reduce low energy photon flux. Now, choose the working magnification between 0.5 x and 40 x and fit the field of view to encompass the whole sample while maximizing resolution. To increase the resolution, place the x-ray source closer to the sample.

To increase the field of view, place the detector closer to the sample. For 3D imaging, the sample must fit within the field of view at any angle of rotation, so the axis of rotation must be centered. Begin by rotating the sample to negative 20 degrees.

If the desired volume has shifted laterally, reposition the rotation axis. Proceed with taking images at further rotations and continue making corrections until the sample is fully visible from negative 90 to positive 90 degrees, then proceed with measurement at all angles between negative 90 and 90 degrees. Running an imaging program can take a long time, so plan accordingly.

For example, to image the most femur at Forex magnification with eight micron resolution requires 1000 projection images. This only takes three hours to complete. However, it takes 10 hours to collect the 2, 500 projection images needed to visualize rat lungs at 0.5 x magnification and 16 micron resolution.

For future image comparison, it is necessary to calibrate the image by taking images of a standard phantom made of artificial materials that have bone like and waterlike x-ray absorption under the same experimental conditions. As for the sample, after recording all projection images, the full volume is reconstructed. To calibrate the reconstructed image to the values for the phantom, use the hounds field or CT scale.

For example, at Forex magnification, the waterlike value in the phantom is set to zero and the bone like value is set to 3000 from this range. All other values are interpolated or extrapolated. The images can now be analyzed using any software package that can support 20 gigabyte files, such as freeware image J, or Fiji.

This volume rendering shows the femur of a mouse four days after bone mineralization has initiated the mineralized fraction calculated at 18%and the bone mineral density can be compared to bones in other stages of development. This tomographic volume rendering of lungs from a 12 week old female nude rat is resolved to 16 microns. Pulmonary staining is used to reveal 20 micron diameter blood vessels.

In this serial section analysis of the same lungs. Multiple cancer nodules can be seen as solid gray shapes within four weeks of implanting tumor cells. In these lungs, nodules grew to cover 17%of the lungs volume.

Most of the pulmonary staining was found in the peripheral areas of the tumors. Blood vessels are also present inside the nodules, covering some 3%of their volume. Once mastered, sample positioning can be done in 15 to 20 minutes if it is performed properly.

The imaging time including automatic volume reconstruction, which usually does not require the presence of an operating person, depends on the sample and may take as long as 50 hours. Don't forget that working with fixating and staining agents can be extremely hazardous. Always wear lab gloves and avoid breathing vapors from the samples.

View the full transcript and gain access to thousands of scientific videos

Sign In Start Free Trial

Explore More Videos

High Resolution3D ImagingEx-vivo Biological SamplesMicro CTTomographic TechniquesX-ray Micro Computerized TomographyVersatile TechniqueAccurate ResolutionElectron TomographyThick SamplesFew Hours Of MeasurementHistological MethodsSample ConditioningPositioningMicrofocused X-ray SourceDetectorScintillatorCCD CameraVolume ReconstructionRotation Step

Related Videos

Contrast Enhanced Vessel Imaging using MicroCT

05:50

Contrast Enhanced Vessel Imaging using MicroCT

Related Videos

13K Views

Rigid Embedding of Fixed and Stained, Whole, Millimeter-Scale Specimens for Section-free 3D Histology by Micro-Computed Tomography

07:41

Rigid Embedding of Fixed and Stained, Whole, Millimeter-Scale Specimens for Section-free 3D Histology by Micro-Computed Tomography

Related Videos

9.2K Views

Microfocus X-ray CT (microCT) Imaging of Actinia equina (Cnidaria), Harmothoe sp. (Annelida), and Xenoturbella japonica (Xenacoelomorpha)

08:09

Microfocus X-ray CT (microCT) Imaging of Actinia equina (Cnidaria), Harmothoe sp. (Annelida), and Xenoturbella japonica (Xenacoelomorpha)

Related Videos

9.4K Views

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography

07:01

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography

Related Videos

10.1K Views

A Sectioning, Coring, and Image Processing Guide for High-Throughput Cortical Bone Sample Procurement and Analysis for Synchrotron Micro-CT

07:10

A Sectioning, Coring, and Image Processing Guide for High-Throughput Cortical Bone Sample Procurement and Analysis for Synchrotron Micro-CT

Related Videos

5.4K Views

Whole Animal Imaging of Drosophila melanogaster using Microcomputed Tomography

10:36

Whole Animal Imaging of Drosophila melanogaster using Microcomputed Tomography

Related Videos

5.3K Views

A 3D Cartographic Description of the Cell by Cryo Soft X-ray Tomography

08:47

A 3D Cartographic Description of the Cell by Cryo Soft X-ray Tomography

Related Videos

4.4K Views

Sample Preparation by 3D-Correlative Focused Ion Beam Milling for High-Resolution Cryo-Electron Tomography

08:20

Sample Preparation by 3D-Correlative Focused Ion Beam Milling for High-Resolution Cryo-Electron Tomography

Related Videos

3.8K Views

High-Resolution Three-Dimensional Whole-Organ Tomography of Microbial Infections

08:01

High-Resolution Three-Dimensional Whole-Organ Tomography of Microbial Infections

Related Videos

1.3K Views

Pipeline for Multi-Scale Three-Dimensional Anatomic Study of the Human Heart

04:22

Pipeline for Multi-Scale Three-Dimensional Anatomic Study of the Human Heart

Related Videos

812 Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2025 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code