-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Medicine
A Chronic Cardiac Ischemia Model in Swine Using an Ameroid Constrictor
A Chronic Cardiac Ischemia Model in Swine Using an Ameroid Constrictor
JoVE Journal
Medicine
This content is Free Access.
JoVE Journal Medicine
A Chronic Cardiac Ischemia Model in Swine Using an Ameroid Constrictor

A Chronic Cardiac Ischemia Model in Swine Using an Ameroid Constrictor

Full Text
10,854 Views
08:22 min
October 9, 2017

DOI: 10.3791/56190-v

Karen J. Keeran*1, Kenneth R. Jeffries1, Arthur D. Zetts1, Joni Taylor1, Shawn Kozlov1, Timothy J. Hunt*1

1Animal Surgery and Resources Core, National Heart, Lung, and Blood Institute,National Institutes of Health

Summary

The purpose of this protocol is to demonstrate the placement of a delayed constricting device (an ameroid constrictor) around a coronary artery in a swine model. This device creates an ischemic area of the heart that is useful for studying new diagnostic imaging techniques and new methods of treatment.

Transcript

The overall goal of this surgical procedure for placing a delayed constrictor device around a coronary artery in a pig is to develop a cardiac ischemia model that is useful for developing and evaluating new methods of treatment for heart disease. This method for inducing cardiac ischemia in swine is valuable in the field of cardiovascular research, as it allows researchers to study the efficacy of new diagnostic imaging techniques and new methods for treatment of cardiovascular disease. Main advantage of the delayed constrictor is that it is made in various sizes to accommodate the anatomy and the size of the vessel to be constricted.

Additionally, the surgery is a relatively simple one and there is no post-operative maintenance of the device. Demonstrating the procedure will be Kenneth Jeffries and Arthur Zetts. Both are staff members from the Animal Surgery and Resources Core.

After anesthetizing, catheterizing and shaving the pig, move it into the operating room. There, position it right side down on the operating table and connect the endotracheal tube to the anesthesia machine. Mechanically ventilate the pig, starting at a tidal volume of 10 milliliters per kilogram.

Then, adjust the ventilator to an airway pressure of about 15 centimeters of water, but never exceed 30 or the lungs will be damaged. Set the respiratory rate between 10 and 20 breaths per minute and adjust as needed to keep the end tidal carbon dioxide levels at 28 to 35 millimeters of mercury. Next, extend the left front leg forward and secure it to the operating table.

Then, attach all the probes needed to monitor body temperature, electrocardiogram, pulse oximetry and so forth. Now, prepare the surgical site using three alternating scrubs of 2%chlorhexidine and 70%alcohol. Use a circular motion, beginning with center and move outwards.

After scrubbing, drape the surgical site and proceed with the surgery. Begin the surgery by exposing the heart through a left thoracotomy. Using a number 10 scalpel, make an eight to nine centimeter incision, parallel to the fourth and fifth intercostal spaces.

Next, used curved Metzenbaum scissors and Brown-Adson forceps to cut through the latissimus dorsi and serratus ventralis. As needed, use electrocautery to maintain hemostasis. Now, enter the pleural cavity through the intercostal muscles between the fourth and fifth ribs by using Metzenbaum scissors to cut along the anterior aspect of the fourth rib.

Just before entering the cavity, temporarily turn off the ventilator. Then, open the cavity with a reduced chance of accidentally damaging the lungs. Once the cavity is opened, turn the ventilator back on.

Next, use a small Finochietto Retractor to spread the ribs and expose the heart. Then, use Debakey forceps to grasp and lift the pericardium. Now, use Potts scissors to make a small hole in the pericardium, allowing air to enter the pericardial space.

Continue the incision with the Potts scissors over the junction of the LAD and LCX arteries. Next, use Babcock forceps to retract the left atrial appendage. Then, with Debakey forceps and small right-angle forceps, dissect the LCX artery from the surrounding tissue, prior to or proximal to, the first obtuse marginal branch.

Next, place two vessel loops under the dissected LCX artery, one at each end, and prepare to position an Ameroid constrictor. Select a constrictor that will closely encircle the vessel without initially constricting the vessel. Hold the Ameroid constrictor with small right-angle forceps and lift the vessel loops to gently guide the LCX artery through the opening of the constrictor.

Then, gently rotate the constrictor so the opening is facing up and remove the vessel loops. Now, reapproximate the pericardium and close it with 4-0 polypropylene sutures. Then, place three to four polyester sutures, size five, around the ribs, which will be tied later to reapproximate the ribs.

Then, to reestablish negative thoracic pressure, insert and 12 French chest tube into the pleural space between the layers of closure, generally two intercostal spaces caudal to the thoracotomy site. Before proceeding, observe the lung for atelectasis. If any signs of under-inflation are observed, reinflate the lungs manually, up to a pressure of 30 millimeters of mercury.

Now, close the ribs using the pre-placed sutures. Then, close the chest using size one polypropylene sutures for the intercostal layer and use size zero polypropylene sutures for the serratus and fascial layer. Then, use 2-0 polypropylene sutures for the subcutaneous layer, followed by 3-0 polypropylene sutures for the subcuticular layer.

Finally, staple or suture the skin closed. Now, attach a three-way stopcock to the end of the chest tube and evacuate the chest air using a 40 to 60cc syringe, until a negative pressure is achieved. Then, roll the animal onto its sternum, or opposite side, to remove all the air from the chest.

Once the chest maintains a negative pressure, place a size 3-0 polypropylene purse string suture around the chest tube site. While applying tension to the purse string, maintain negative pressure on the chest tube while withdrawing it from the thoracic cavity. Then, tighten and secure the purse string.

Finally, administer bupivacaine around the incision site for long acting local anesthesia. Ameroid placement surgeries were performed over a two years period on 25 Yorkshire pigs, weighing between 12 and 15 kilograms. Twenty survived to the follow-up procedure, two fibrillated and died shortly after closing, two were euthanized for severe heart failure and pulmonary edema, and one had an anesthetic death during a follow-up radiograph.

Survivors underwent a second thoracotomy and were followed out for up to 16 weeks. At 28 days post-ameroid placement, animals were imaged by MRI to measure their heart function and the size of the ischemic area. The ameroid was either titanium encased or plastic encased.

Once mastered, this technique can be done in 60 to 90 minutes if it is performed properly. While attempting this procedure, it's important to remember to perform careful yet adequate dissection around the artery. Too little dissection may cause kinking of the artery, whereas overly aggressive tissue handling may cause excess scarring around it.

After its development, this technique provided a way for investigators in the field of cardiovascular research to explore new methods for treating heart disease.

Explore More Videos

Cardiac IschemiaSwine ModelAmeroid ConstrictorCoronary ArteryCardiovascular ResearchDiagnostic ImagingCardiovascular DiseaseSurgical ProcedureDelayed Constrictor DeviceThoracotomyElectrocauteryHemostasisAnesthesiaVentilationECGPulse OximetryTemperature Monitoring

Related Videos

Myocardial Infarction and Functional Outcome Assessment in Pigs

12:03

Myocardial Infarction and Functional Outcome Assessment in Pigs

Related Videos

28.3K Views

Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine

12:37

Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine

Related Videos

13.7K Views

Tachycardia-Induced Cardiomyopathy As a Chronic Heart Failure Model in Swine

10:08

Tachycardia-Induced Cardiomyopathy As a Chronic Heart Failure Model in Swine

Related Videos

13.8K Views

Surgical Swine Model of Chronic Cardiac Ischemia Treated by Off-Pump Coronary Artery Bypass Graft Surgery

09:12

Surgical Swine Model of Chronic Cardiac Ischemia Treated by Off-Pump Coronary Artery Bypass Graft Surgery

Related Videos

9.7K Views

Establishing a Swine Model of Post-myocardial Infarction Heart Failure for Stem Cell Treatment

08:24

Establishing a Swine Model of Post-myocardial Infarction Heart Failure for Stem Cell Treatment

Related Videos

7.2K Views

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease

06:39

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease

Related Videos

7K Views

Myocardial Infarction by Percutaneous Embolization Coil Deployment in a Swine Model

05:52

Myocardial Infarction by Percutaneous Embolization Coil Deployment in a Swine Model

Related Videos

3.2K Views

A Minimally Invasive Model of Aortic Stenosis in Swine

06:51

A Minimally Invasive Model of Aortic Stenosis in Swine

Related Videos

1.4K Views

Normothermic Cardiac Arrest and Cardiopulmonary Resuscitation: A Mouse Model of Ischemia-Reperfusion Injury

10:25

Normothermic Cardiac Arrest and Cardiopulmonary Resuscitation: A Mouse Model of Ischemia-Reperfusion Injury

Related Videos

18.5K Views

A Swine Model of Neonatal Asphyxia

10:36

A Swine Model of Neonatal Asphyxia

Related Videos

14.6K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2025 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code