-1::1
Simple Hit Counter
Skip to content

Products

Solutions

×
×
Sign In

EN

EN - EnglishCN - 简体中文DE - DeutschES - EspañolKR - 한국어IT - ItalianoFR - FrançaisPT - Português do BrasilPL - PolskiHE - עִבְרִיתRU - РусскийJA - 日本語TR - TürkçeAR - العربية
Sign In Start Free Trial

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

Behavior
Biochemistry
Bioengineering
Biology
Cancer Research
Chemistry
Developmental Biology
View All
JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

Biological Techniques
Biology
Cancer Research
Immunology
Neuroscience
Microbiology
JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduate courses

Analytical Chemistry
Anatomy and Physiology
Biology
Calculus
Cell Biology
Chemistry
Civil Engineering
Electrical Engineering
View All
JoVE Science Education

Visual demonstrations of key scientific experiments

Advanced Biology
Basic Biology
Chemistry
View All
JoVE Lab Manual

Videos of experiments for undergraduate lab courses

Biology
Chemistry

BUSINESS

JoVE Business

Video textbooks for business education

Accounting
Finance
Macroeconomics
Marketing
Microeconomics

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Authors

Teaching Faculty

Librarians

K12 Schools

Biopharma

Products

RESEARCH

JoVE Journal

Peer reviewed scientific video journal

JoVE Encyclopedia of Experiments

Video encyclopedia of advanced research methods

JoVE Visualize

Visualizing science through experiment videos

EDUCATION

JoVE Core

Video textbooks for undergraduates

JoVE Science Education

Visual demonstrations of key scientific experiments

JoVE Lab Manual

Videos of experiments for undergraduate lab courses

BUSINESS

JoVE Business

Video textbooks for business education

OTHERS

JoVE Quiz

Interactive video based quizzes for formative assessments

Solutions

Authors
Teaching Faculty
Librarians
K12 Schools
Biopharma

Language

English

EN

English

CN

简体中文

DE

Deutsch

ES

Español

KR

한국어

IT

Italiano

FR

Français

PT

Português do Brasil

PL

Polski

HE

עִבְרִית

RU

Русский

JA

日本語

TR

Türkçe

AR

العربية

    Menu

    JoVE Journal

    Behavior

    Biochemistry

    Bioengineering

    Biology

    Cancer Research

    Chemistry

    Developmental Biology

    Engineering

    Environment

    Genetics

    Immunology and Infection

    Medicine

    Neuroscience

    Menu

    JoVE Encyclopedia of Experiments

    Biological Techniques

    Biology

    Cancer Research

    Immunology

    Neuroscience

    Microbiology

    Menu

    JoVE Core

    Analytical Chemistry

    Anatomy and Physiology

    Biology

    Calculus

    Cell Biology

    Chemistry

    Civil Engineering

    Electrical Engineering

    Introduction to Psychology

    Mechanical Engineering

    Medical-Surgical Nursing

    View All

    Menu

    JoVE Science Education

    Advanced Biology

    Basic Biology

    Chemistry

    Clinical Skills

    Engineering

    Environmental Sciences

    Physics

    Psychology

    View All

    Menu

    JoVE Lab Manual

    Biology

    Chemistry

    Menu

    JoVE Business

    Accounting

    Finance

    Macroeconomics

    Marketing

    Microeconomics

Start Free Trial
Loading...
Home
JoVE Journal
Biology
In Vivo Surface Electrocardiography for Adult Zebrafish
In Vivo Surface Electrocardiography for Adult Zebrafish
JoVE Journal
Biology
This content is Free Access.
JoVE Journal Biology
In Vivo Surface Electrocardiography for Adult Zebrafish

In Vivo Surface Electrocardiography for Adult Zebrafish

Full Text
14,936 Views
09:13 min
August 1, 2019

DOI: 10.3791/60011-v

Yali Zhao1, Morgan Yun1, Sean A. Nguyen1, Michelle Tran1, Thao P. Nguyen1

1Department of Medicine, Division of Cardiology, the Cardiovascular Research Laboratory,David Geffen School of Medicine at UCLA

Overview

This study presents a practical method for in vivo electrocardiography in adult zebrafish, enabling reliable cardiac monitoring essential for both basic research and drug screening. By repurposing mammalian data acquisition systems, this minimally invasive technique yields insights into cardiac physiology relevant to human health.

Key Study Components

Research Area

  • Cardiac physiology
  • Drug screening for cardiotoxicities
  • Zebrafish as a model organism

Background

  • Understanding cardiovascular health in zebrafish can inform human cardiac studies.
  • Electrocardiography is crucial for evaluating cardiac function and drug effects.
  • Zebrafish share several ECG characteristics with humans despite having simpler cardiac anatomy.

Methods Used

  • In vivo electrocardiography techniques
  • Adult zebrafish as the biological model
  • Real-time ECG interpretation using a repurposed data acquisition system

Main Results

  • A method for accurately positioning ECG electrodes to maximize signal quality was established.
  • Validating normal vs. pathological ECG patterns was emphasized for accurate data interpretation.
  • The study confirmed the utility of zebrafish ECGs in modeling human cardiac responses.

Conclusions

  • This method enhances the ability to use zebrafish in cardiovascular studies and drug safety testing.
  • It demonstrates the relevance of non-mammalian models in understanding human cardiac physiology.

Frequently Asked Questions

What preparations are needed before recording ECGs in zebrafish?
Adult zebrafish should be anesthetized to level 4 and positioned ventral side up on a damp sponge for electrode placement.
Why is lead positioning critical in ECG recording?
Correct lead placement maximizes signal quality and ensures clear differentiation of ECG waves.
Can zebrafish ECGs be used to approximate human cardiac conditions?
Yes, zebrafish share ECG features with humans, making them a suitable model for studying human cardiac physiology.
What types of cardiac abnormalities can be assessed using this method?
It can be used to evaluate QT prolongation and other cardiotoxicities during drug screening.
Is the process for analyzing ECG data automated?
While some aspects can be automated, manual verification of wave formation and intervals is crucial for accurate results.
What is the significance of the T wave in zebrafish ECGs?
The T wave represents ventricular repolarization, and its amplitude is important for assessing lead placement.
How long does it take for a zebrafish to recover from anesthesia?
A zebrafish is considered fully recovered when it can swim upright for at least five seconds after being placed in oxygenated water.

Here, we present a reliable, minimally invasive, and cost-effective method to record and interpret electrocardiograms in live anesthetized adult zebrafish.

In vivo electrical cardiography is the only diagnostic tool for electrical phenotyping in live zebrafish in cross-sectional and longitudinal studies. Our approach is practical, minimally invasive, and cost effective because we repurpose a data acquisition system for mammals. We emphasize the strategy of real-time ECG interpretation for early validation of data quality.

Because human and zebrafish ECGs are similar, in vivo electrocardiography facilitates the use of zebrafish in modeling human cardiac physiology as well as high throughput drug screening for cardiotoxicities, such as QT prolongation. Correct lead positioning is the key to success. Because the normal zebrafish T wave is the smallest, prioritize optimizing its amplitude over those of the larger P and R waves.

Study normal and pathological ECG patterns to interpret your ECG findings yourselves. Do not rely solely on automatic interpretation of ECG analysis software. On the day of the experiment, transport the zebrafish from the aquarium to the laboratory.

To set up the in vivo ECG recording system, connect the essential pieces of equipment and insert the three color-coded, stainless steel electrodes of the ECG lead into the three color-matched access portals of the amplifier. For induction of level 4 anesthesia, immerse an adult zebrafish in a dish containing a solution of anesthetics at the lowest pre-determined concentrations approved by the institutional animal care and use committee. Once the zebrafish has maintained level 4 anesthesia for three seconds, use a pair of blunt forceps to immediately transfer the fish onto a damp sponge with a slit, ventral surface up, for placement of the three ECG electrodes.

Gently insert the positive electrode in the ventral midline at the level of the bulbus arteriosus one to two millimeters above an imaginary line connecting the two lower edges of the operculums. Position the negative electrode caudally and 0.5 to one millimeter left laterally to the positive electrode at a distance greater than the maximal apicobasal length of the adult zebrafish ventricle, then position the reference electrode caudally near the anal region. For ECG recording, start the system and open the ECG data acquisition program.

Select a desired setting from the drop-down menus for range, low pass, and high pass. Press Start to initiate continuous gap-free ECG recording at a sampling rate of one kilohertz. To optimize lead positioning for maximal signal-to-noise ratio, press Stop to stop the recording and review the trace soon after the very first recording attempt for each heart.

If the ECG is expected to be normal, confirm that all ECG waveforms are distinct and readily visible and that the P wave, net QRS complex, and T wave are all positive. The single most critical step is lead positioning to maximize the signal-to-noise ratio. Apply our four validating criteria after the very first ECG recording attempt for each fish to obtain corrective feedback.

If a normal ECG is expected, reposition the electrodes as necessary until all of these four validating criteria are satisfied. If a normal T wave is expected, but the T wave is too small, reposition the electrodes to maximize the T wave amplitude. Resume the ECG recording after optimizing the lead positioning, saving the ECG sweeps for subsequent analysis.

At the end of the ECG recording session, carefully remove the electrodes without injuring the fish. In survival studies, transfer the fish to fresh, oxygenated fish water free of tricaine. Please note that, in this video, to facilitate readers'viewing of the fish recovery from anesthesia, oxygenation is discontinued.

To facilitate recovery from the anesthesia in survival studies, use a Pasteur pipette to vigorously squirt water over the gills until the fish resumes regular gill movement or swimming, then monitor the fish for full recovery from anesthesia before returning the fish to the aquarium. The fish is considered fully recovered from anesthesia when it can swim upright for at least five seconds. To define the analysis settings, open the ECG data analysis program and open the ECG file of interest to display the full ECG trace.

Use the mouse to drag out a section of interest in the ECG trace to analyze. From the ECG Analysis menu, select ECG Settings to open a dialogue box to predefine various parameter settings for software automatic analysis. Analyze the heart rhythm and rate and determine whether the heart rhythm is sinus or not, regular or irregular.

To determine the heart rate, ensure that the software correctly identifies all of the P and R waves because the atrial and ventricular rate is based on the PP and RR interval, respectively. Correct any auto-identification mistakes by moving the misplaced cursors to the appropriate P and R waves. To calculate intervals and wave durations, open ECG analysis and averaging view to concatenate several consecutive cardiac cycles into a single average signal.

Ensure that the software correctly identifies the start and end of the P wave, the QRS complex, and the T wave, then move the misplaced cursors to the appropriate positions to correct any auto-identification mistakes. To export the ECG measurements, select Table View to review all of the ECG measurements and copy and paste the measurements of interest into a spreadsheet for subsequent analysis. To export an ECG trace, use the magnifier to highlight a section of interest in the ECG sweep and copy and paste the sweep into the desired document.

In contract to the human heart, which has two atria and two ventricles, the zebrafish heart has only one atrium and one ventricle. Despite its apparent anatomical simplicity, the zebrafish heart shares several ECG features with the human heart. Proper lead placement requires aligning the lead with the presumed cardiac main axis.

When the electrodes are inserted too superficially in the dermis, the lead is considered indirect-like and the voltage signals are small. When the electrodes are inserted to the appropriate one-millimeter depth into the pectoralis musculature, the lead becomes semi-direct and the voltage signals increase. If the electrodes are inserted deeper than one millimeter into the ventricle, however, the lead becomes direct and the voltage signals increase even further, with the R wave amplitude increasing by four-fold compared to when the electrodes are inserted at the appropriate depth.

The ECG trace from too-deeply inserted electrodes also reveals new signs of injury to the ventricular myocardium, such as a new ST depression and a new T wave inversion. If the positive and negative electrodes are switched in their placement, unusual inversions of all of the ECG waveforms are observed. An inappropriate level of sedation depth can also impair the quality of the in vivo ECG recording.

Remember to anesthetize deeply enough to immobilize the fish without killing it. Position the electrodes to maximize the signal-to-noise ratio and avoid over-reliance on automatic software analysis. Following this minimally invasive survival procedure, it is possible to perform other procedures such as partial ablation, resection of the heart, or serial ECG investigations in drug responses or longitudinal studies.

Systemic toxicities are potential complications of any anesthetic, including tricaine. These toxicities can be reduced by capitalizing on the synergy of multiple anesthetics to lower the dose of individual agents.

Explore More Videos

In Vivo ElectrocardiographyZebrafishElectrical CardiographyECG InterpretationCardiac PhysiologyDrug ScreeningQT ProlongationLead PositioningAnesthesiaECG ElectrodesData Acquisition SystemECG PatternsECG Recording

Related Videos

Zebrafish Electrocardiography (ECG): A Minimally Invasive Assay to Evaluate Cardiac Function

05:15

Zebrafish Electrocardiography (ECG): A Minimally Invasive Assay to Evaluate Cardiac Function

Related Videos

3.5K Views

Adult Zebrafish Electrophysiology: A Method to Measure the Extracellular Electrical Activity of Neurons In Vivo

03:11

Adult Zebrafish Electrophysiology: A Method to Measure the Extracellular Electrical Activity of Neurons In Vivo

Related Videos

2.4K Views

Electrophysiological Recording in the Brain of Intact Adult Zebrafish

09:42

Electrophysiological Recording in the Brain of Intact Adult Zebrafish

Related Videos

22.4K Views

Recovery of Adult Zebrafish Hearts for High-throughput Applications

06:51

Recovery of Adult Zebrafish Hearts for High-throughput Applications

Related Videos

13K Views

Visualization of Cellular Electrical Activity in Zebrafish Early Embryos and Tumors

08:55

Visualization of Cellular Electrical Activity in Zebrafish Early Embryos and Tumors

Related Videos

9.4K Views

High-Frequency Ultrasound Echocardiography to Assess Zebrafish Cardiac Function

08:34

High-Frequency Ultrasound Echocardiography to Assess Zebrafish Cardiac Function

Related Videos

9.8K Views

Isolation of Cardiac and Vascular Smooth Muscle Cells from Adult, Juvenile, Larval and Embryonic Zebrafish for Electrophysiological Studies

07:04

Isolation of Cardiac and Vascular Smooth Muscle Cells from Adult, Juvenile, Larval and Embryonic Zebrafish for Electrophysiological Studies

Related Videos

2.9K Views

4D Light-sheet Imaging of Zebrafish Cardiac Contraction

07:07

4D Light-sheet Imaging of Zebrafish Cardiac Contraction

Related Videos

1.9K Views

Zebra II as A Novel System to Record Electrophysiological Signals in Zebrafish

06:15

Zebra II as A Novel System to Record Electrophysiological Signals in Zebrafish

Related Videos

886 Views

Anesthesia-free Heartbeat Measurements in Freely Moving Zebrafish

03:57

Anesthesia-free Heartbeat Measurements in Freely Moving Zebrafish

Related Videos

1.2K Views

JoVE logo
Contact Us Recommend to Library
Research
  • JoVE Journal
  • JoVE Encyclopedia of Experiments
  • JoVE Visualize
Business
  • JoVE Business
Education
  • JoVE Core
  • JoVE Science Education
  • JoVE Lab Manual
  • JoVE Quizzes
Solutions
  • Authors
  • Teaching Faculty
  • Librarians
  • K12 Schools
  • Biopharma
About JoVE
  • Overview
  • Leadership
Others
  • JoVE Newsletters
  • JoVE Help Center
  • Blogs
  • JoVE Newsroom
  • Site Maps
Contact Us Recommend to Library
JoVE logo

Copyright © 2026 MyJoVE Corporation. All rights reserved

Privacy Terms of Use Policies
WeChat QR code