A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Uncontrolled Hemorrhagic Shock Modeled via Liver Laceration in Mice with Real Time Hemodynamic Monitoring

8.5K views

⸱

DOI:

10.3791/55554

⸱

May 21st, 2017

 ,  ,  ,  ,  , 

In This Article

Summary

Uncontrolled hemorrhage, an important cause of mortality among trauma patients, can be modeled using a standard liver laceration in a murine model. This model results in consistent blood loss, survival, and allows for testing hemostatic agents. This article provides the step-by-step process to perform this valuable model.

Abstract

Uncontrolled hemorrhage is an important cause of preventable deaths among trauma patients. We have developed a murine model of uncontrolled hemorrhage via a liver laceration that results in consistent blood loss, hemodynamic alterations, and survival.

Mice undergo a standardized resection of the left-middle lobe of the liver. They are allowed to bleed without mechanical intervention. Hemostatic agents can be administered as pre-treatment or rescue therapy depending on the interest of the investigator. During the time of hemorrhage, real-time hemodynamic monitoring via a left femoral arterial line is performed. Mice are then sacrificed, blood loss is quantified, blood is collected for further analysis, and organs are harvested for analysis of injury. Experimental design is described to allow for simultaneous testing of multiple animals.

Liver hemorrhage as a model of uncontrolled hemorrhage exists in the literature, primarily in rat and porcine models. Some of these models utilize hemodynamic monitoring or quantify blood loss but lack consistency. The present model incorporates quantification of blood loss, real-time hemodynamic monitoring in a murine model that offers the advantage of using transgenic lines and a high-throughput mechanism to further investigate the pathophysiologic mechanisms in uncontrolled hemorrhage.

Introduction

Trauma is the leading cause of death and disability among young people worldwide.1 Uncontrolled hemorrhage remains a leading cause of mortality among severely injured trauma patients.2 Management of the hemorrhaging trauma patient is two-fold: control of surgical bleeding, and resuscitation and replacement of lost blood.

Animal models of hemorrhagic shock have been the cornerstone in trauma research and can be used in the evaluation of the pathophysiology and treatment of traumatic/hemorrhagic shock.3,4 Shock in animal models can be ac....

Access restricted. Please log in or start a trial to view this content.

Protocol

Mice were housed in accordance with University of Pittsburgh (Pittsburgh, PA, USA) and National Institutes of Health (NIH; Bethesda, MD, USA) animal care guidelines in specific pathogen-free conditions with 12 h light-dark cycles and free access to standard feed and water. All animal experiments were approved and conducted in accordance with the guidelines set forth by the Animal Research and Care Committee at the University of Pittsburgh.

1. Surgical Field and Instrument Setup

  1. Sterilize all surgical instruments, suture, gauze, cotton tip applicators, tubing, and tubing connectors prior to the procedure.
      ....

Access restricted. Please log in or start a trial to view this content.

Results

The liver laceration model results in reproducible and consistent blood loss in mice. Figure 1A demonstrates the consistent weight of lacerated liver that can be obtained with a standard deviation of only 0.02 g. This consistency in lacerated liver weight allows the ability to reproduce the model between mice and in different experimental set-ups such as different resuscitative protocols. As well, the reproducible weight of the lacerated liver, with a standard error of on.......

Access restricted. Please log in or start a trial to view this content.

Discussion

The murine liver laceration model described here provides a reliable, consistent model of uncontrolled hemorrhage. This model is straightforward to perform but there are important steps that require meticulous consideration. The most technically challenging part of the model is cannulation of the femoral vessels for hemodynamic monitoring and fluid/drug administration. Care must be taken during the dissection of the nerve and the arteriotomy/venotomy. It is important to not touch the nerve during the dissection of the ve.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have no financial competing interests to declare.

Acknowledgements

The work of this manuscript was supported by funding to Dr. Neal by the Vascular Medicine Institute Pilot Project Program in Hemostasis and Vascular Biology (P3HVB) and the AAST Research Fellowship. This work is supported by U.S. National Institutes of Health grants 1 R35 GM119526-01 and UM1HL120877-01.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
SS/45 dumontsFine Science Tools11203-25
surgical scissorsFine Science Tools14068-12
hemostatsFine Science Tools13009-12
microscissorsFine Science Tools15000-08
0.8 mm curved forcepsFine Science Tools11009-13
suture reel 6-0Fine Science Tools18020-60
suture 4-0 silk w/ needleOwens MinorK188H
gauze 4 x 4can be purchased through any global vendor
cotton-tip applicatorcan be purchased through any global vendor
30 G needlecan be purchased through any global vendor
23 G needlecan be purchased through any global vendor
10 cc syringecan be purchased through any global vendor
50 cc conical tubecan be purchased through any global vendor
1 cc syringe w/ 25G needleFisher Scientific14-826-88
Polyethylene 10 tubing 100`(PE-10)Fisher Scientific14-170-12P
Polyethylene 50 tubing 100`(PE-50)Fisher Scientific14-170-12B
3-way stopcockFisher ScientificNC9779127
surgical blue padFisher Scientific50-7105
Sterile Field dressingsFisher ScientificNC9517505
tape rolls 1"Corporate ExpressMMM26001
straight side wide mouth jarsVWR159000-058
stainless steel tray 8" x 11"VWR62687-049
male-male leur lock 3-wayVWR20068-909
sterilization pouch 3" x 8"VWR24008
sterilization pouch 5" x 10"VWR24010
absorption trianglesFine Science Tools18105-03
7 mm wound clip applierFisher ScientificE0522687
1,000 7 mm wound clipsFisher ScientificE0522687
betadine (4 oz)can be purchased through any global vendor
sterile glovescan be purchased through any global vendor
eppendorfs can be purchased through any global vendor
1/2 cc Lo-Dose insulin syringeFisher Scientific12-826-79
small weigh boatcan be purchased through any global vendor
lactated ringerscan be purchased through any global vendor
hepranized saline solution (.1 µL; hep + 9.9 µL; NaCl)can be purchased through any global vendor
phosphate buffered saline can be purchased through any global vendor
pentobarbital can be purchased through any global vendor
Wild M650 microscope w/ boom standLeica
Digi-Med BPA-400 analyzer & systems integratorMicro-MedSYS-400
TXD-310 (Digi-Med Transducer) Micro-MedTXD-300
ComputerDell
microbead instrument sterilizerVWR11156-002
Oster A5 clippers w. size 40 bladeVWR10749-020
circulating heating pad 18 x 26Harvardpy872-5272
rectal thermometerKent ScientificRET-3

References

  1. Chang, R., Cardenas, J. C., Wade, C. E., Holcomb, J. B. Advances in the understanding of trauma-induced coagulopathy. Blood. 128 (8), 1043-1049 (2016).
  2. Kutcher, M. E., et al. A paradigm shift in trauma resuscitation: evaluation of evolving massive transfusion practices. JAMA surgery. 148 (9), 834-840 (2013).
  3. Tsukamoto,....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Murine ModelBlood Loss QuantificationFemoral Arterial LineHemostatic AgentsResuscitation PracticesTransgenic MiceHigh Throughput Model