$$\rightleftharpoonup{xx}$$
$$\longleftharp{xx}$$,
$$\longrightharp{xx}$$,
Recent publications from our group showed that X-ray patterns from the mouse skeletal muscle can be used to shed light on sarcomeric structural information from muscle in health and disease1,2,3 especially with the increased availability of genetic modified mouse models for various myopathies. High resolution mechanical studies on single fibers or small bundles combined with X-ray diffraction is best done by experts. If, however, more modest mechanical information will suffice for your purposes, the whole muscle preparation allows collection of detailed X-ray patterns from a simple preparation.
A clean dissection is key to a successful combined mechanical and X-ray experiment. It is very important not to pull on the target muscle as well as other muscles associated with the soleus or EDL muscles during dissection since this could tear parts of the muscle and lead to reduced force. It can also lead to damaged internal structure that will degrade the X-ray patterns. Since everything will scatter in the X-ray beam, it is important to cleaning away any extra fat, the collagen in fascia as well as any hairs or loose bits of tissue while doing the following protocol. To reduce additional compliance in the muscle preparation, it is also important to securely tie the tendons to the hooks, as close as possible to the muscle body without damaging it.
Different X-ray exposure times can provide different kinds of information from the same muscle. Using the full beam on 18ID, an analyzable equatorial pattern can be obtained in a 1 ms exposure (See Figure 2D). For an analyzable first myosin layer line reflection, a 10 ms total exposure time is typically required. To collect higher order meridional reflections such as the M15 (2.8 nm myosin meridional reflection) and the 2.7 nm actin meridional reflection, typically at least 1 s total exposure is required but more than 2 s total exposure is recommended for high accuracy measurements.
The choice of the optimal X-ray detector for the experiment is important. For the most detailed X-ray patterns a customized CCD detector, such as the one at BioCAT with ca. 40 µm pixels and ~65 µm point spread functions in the phosphor, can provide patterns with high dynamic range and good spatial resolution but can only take one frame at a time. For time resolved experiments, the photon counting pixel array detector at BioCAT can collect X-ray patterns at 500 Hz. The 172 µm pixel size with this detector, however, does not provide sufficient spatial resolution for detailed studies of the inner part of the meridian but is adequate for most other purposes. BioCAT acquired a high-resolution photon counting detector providing 75 µm real resolution at maximum frame rate of 9,000 Hz. Similar detectors of this type are expected to supplant current detectors for muscle studies over the next few years.
With the very high fluxes of X-rays at third generation synchrotrons, radiation damage is a serious concern. It is always a good choice to attenuate the beam to deliver no more beam than is needed to observe the desired diffraction features. The same total X-ray exposure can be achieved by prolonging the exposure time from an attenuated beam. An advantage of photon counting pixel array detectors is that individual frames can be summed together with no noise penalty. Even then, radiation damage is possible. Signs of radiation damage includes drop of maximum force of contraction, smearing of layer line reflections, even change of muscle color.
One of the limitations of the intact mouse skeletal muscle preparation is the difficulty in obtaining sarcomere length from the intact muscle during the experiments. The muscles are too thick for video microscopy and laser diffraction. While with future developments it may be possible to estimate sarcomere length directly from the diffraction patterns14, in the near term the only option is to measure it after the experiment as described here.